PS82-20-4MNB-C-FL Gems Sensors Inc, PS82-20-4MNB-C-FL Datasheet - Page 2

Pressure Switch

PS82-20-4MNB-C-FL

Manufacturer Part Number
PS82-20-4MNB-C-FL
Description
Pressure Switch
Manufacturer
Gems Sensors Inc
Datasheet

Specifications of PS82-20-4MNB-C-FL

Contact Voltage Ac Max
250V
Circuitry
SPDT
Operating Pressure Max
948.2mbar
Port Style
NPT
Contact Current Ac Max
5A
Contact Current Max
5A
Contact Voltage Dc Max
28V
Switch Terminals
Wire Leaded
How To Order
Use the Bold characters from the chart below to construct a product code. Please reference Notes.
1 Pressure Range Code
2 Pressure Fitting
3 Circuit
4 Electrical Termination
Table 1 — Vacuum Range Codes
The deadband values tabulated are for the standard microswitch. With either the -SP of -10A option, the deadband
values are typically 50% greater than those listed. With the -RD option, the values will be typically 25% less than
those listed. In certain applications deadband can be tailored and controlled to customer specifications. Consult
factory for details.
* -IP and -EL options are approximate gauge switches. Altitude and temperature changes will result in set point shifts.
Vacuum Range Code
Brass
316 Stainless Steel
-CABXX = 18 AWG PVC Cable
-FLSXX = Flying Leads w/PVC Shrink Tubing
-2MNB = 1/8˝ NPTM
-4MNB = 1/4˝ NPTM
-2MGB = 1/8˝ BSPM (G type)
-4MGB = 1/4˝ BSPM (G type)
-2MNS = 1/8˝ NPTM
-4MNS = 1/4˝ NPTM
-4MGS = 1/4˝ BSPM (G type)
-4MSB = 7/16˝-20 SAE Male
-6MSB = 9/16˝-18 SAE Male
-FLXX = Flying Leads
-ELXX = 1/2˝ NPT Male Conduit w/Flying Leads
Insert Pressure Range Code from Table 1, below.
-HCR = Right Angle DIN 43650A 9mm Cable
-HNR = Right Angle DIN 43650A with 1/2˝ Female
-HM = Micro (9.4mm Spacing) DIN Style Male
-HR = Right Angle DIN 43650A Male Half Only
-HN = DIN 43650A with 1/2˝ Female NPT Conduit
-HC = DIN 43650A 9mm Cable Clamp
-SP = Spade Terminals
-A = SPST/N.O.
-B = SPST/N.C.
-C = SPDT
-H = DIN 43650A Male Half Only
10
20
Clamp
NPT Conduit
Half Only
5
1
5
2
5
6
PS82 -10 -4MNB -C -H
4
12-28” Hg (406-948mbar)
5-15” Hg (169-508 mbar)
Vacuum Range
5
5
Visit www.GemsSensors.com for most current information.
2
1
3
5
5
5 Options
6 Fixed Set Point (optional)
2
-OXY = Oxygen Cleaned
A. Specify set point -FS
B. Set Point Actuation
-WM = Weather Pack Connector, Male
-10A = 10A @ 125/250 VAC Max. Rating
-WF = Weather Pack Connector, Female
-RD = Reduced Differential
-DE = Deutsch Connector, Male, DT04 Series
-IP = Ingress Protection
(in Inches Hg or mBAR, see example)
R on Rising Vacuum
F on Falling Vacuum
Example: -FS300MBARF for 300 mBAR Falling
or -FS10INHGR for 10˝ Hg Rising
-N = Neoprene Diaphragm
-G = Gold Contacts
-V = Viton
-E = EPDM Diaphragm
±0.71” Hg (24 mbar) +2% of setting
±1.63” Hg (55 mbar) +2% of setting
(for loads less than 12 mA @ 12 VDC)
(25% reduction typical)
3
®
Repeatability
Diaphragm
4
8
-XX -XXXX
5
7
9
3.05” Hg (103 mbar) +7% of setting
6.1” Hg (207 mbar) +8% of setting
6
vaCUUm SWITCHES
Average Deadband*
Notes:
1. Other fittings available.
2. 18˝ is standard. Specify lead
3. 18˝ is standard. Specify
4. 36˝ is minimum. Specify
5. DIN connectors require -C
6. Requires -10A, -G options
7. Options -10A, -G or -RD
8. Ingress Protection is
9. Set Point must be within
Consult factory.
length in inches (max. 48˝).
e.g. -FL18 or -FLS30.
lead length in inches (max.
48˝). e.g. -EL18 or -EL30.
cable length in inches.
e.g. -CAB36 or -CAB120.
SPDT circuit.
(50% increase in deadband
typical).
cannot be combined.
available only with -FL, -FLS,
-ELS or -CAB Electrical
Termination choices.
Ingress Protection requires
Fixed Set Point -FS.
Pressure Range selected in
Step 1.
I-26

Related parts for PS82-20-4MNB-C-FL