SCX05DN SENSYM, SCX05DN Datasheet
SCX05DN
Specifications of SCX05DN
Related parts for SCX05DN
SCX05DN Summary of contents
Page 1
... Thus, for many applications no trimming networks are required in the signal ELECTRICAL CONNECTION Bottom view Note: The polarity indicated is for pressure applied to port B (for absolute devices pressure is applied to port A and the output polarity is reversed.) SCX Series Scale ½ ...
Page 2
... SCX Series Precision compensated pressure sensors PRESSURE SENSOR CHARACTERISTICS STANDARD PRESSURE RANGES Part Number Operating pressure SCX01DN SCX05DN SCX15AN SCX15DN SCX30AN SCX30DN SCX100AN SCX100DN SCX150DN Maximum ratings (for all devices) Supply voltage V S Common-mode pressure Lead temperature (soldering, 4 seconds) COMMON PERFORMANCE CHARACTERISTICS ...
Page 3
... Vacuum reference (absolute device) Absolute sensors have a hermetically sealed vacuum reference chamber. The offset voltage on these units is therefore measured at vacuum, 0 psia. Since all pressure is measured relative to a vacuum reference,all changes in barometric pressure or changes in altitude will cause changes in the device output. August 2005 / 053 ...
Page 4
... For blood pressure monitoring applications, the circuit shown in Figure B provides a 0 3.5 V output for 300 mm Hg input pressure. The circuit is easily calibrated and is not affected by changes in the voltage supply. Because 300 approximately 5.8 psi, an SCX05DN is used. . With this configuration, Circuit description REF ...
Page 5
... Repeat procedure if necessary. * For timing specifications and bus interface, see the ADC0804 Datasheet from National Semiconductor. Figure A. Low pressure circuits provide output for a 0-10 in. W.C. pressure input August 2005 / 053 Precision compensated pressure sensors (cont.) Serial A/D conversion The circuit shown in Figure D is similar to that shown in Figure C, except the output is bit serial ...
Page 6
... SCX Series Precision compensated pressure sensors Figure B. Medical application circuit provide a 0.5 to 3.5 V output for a 0-300 mmHg pressure input Figure C. 6/10 A parallel A/D conversion circuit for 0-1 psig applications August 2005 / 053 www.sensortechnics.com ...
Page 7
... Figure D. Serial A/D conversion for 0-1 psig applications and simple test circuit August 2005 / 053 Precision compensated pressure sensors www.sensortechnics.com SCX Series 7/10 ...
Page 8
... Circuit description The LM10CN (A and R provide power the SCX05DN, amplifier high input impedance diff-in, diff-out amplifier. The sensor output is amplified to 200 mV full- scale for the A/D input. R shown. The gain equation is the zero adjust pot and R 4 adjustment ...
Page 9
... August 2005 / 053 Precision compensated pressure sensors Figure F. 0.5 psi switch Figure 200 millibar meter. SCX Series 9/10 www.sensortechnics.com ...
Page 10
... To order, use the following part number(s) Part number SCX01DN SCX05DN SCX15AN SCX15DN SCX30AN 6-pin right angle socket SCX30DN ...