KMTG1603 Kingstate Electronics Corp., KMTG1603 Datasheet - Page 5

PIEZO TRANSDUCER, SMD TYPE

KMTG1603

Manufacturer Part Number
KMTG1603
Description
PIEZO TRANSDUCER, SMD TYPE
Manufacturer
Kingstate Electronics Corp.
Datasheet

Specifications of KMTG1603

Capacitance
14000pF
External Depth
2.6mm
Sound Level Spl
70dB
Sound Level Distance
10cm
Capacitance Max
18.2nF
Current Max
3mA
Current Rating
3mA
External Length / Height
2.6mm
External Width
16mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMTG1603
Manufacturer:
KINGSTAT
Quantity:
6 000
Part Number:
KMTG1603-1
Manufacturer:
KINGSTATE
Quantity:
20 000
TEST CONDITION.
Standard Test Condition
Judgement Test Condition
H. ENVIRONMENT TEST 環境測試
I. RELIABILITY TEST 信賴性測試
No.
No.
1
2
3
3
1
Operating life
一般測試條件
爭議時測試條件
壽命測試
High temp. test
Low temp. test
相對濕度測試
溫度循環測試
Item
Humidity test
Temp. Cycle
test
高溫測試
低溫測試
Item
志豐電子股份有限公司 KINGSTATE ELECTRONICS CORP 5/6 KMTG1603
1.Continuous life test 高溫壽命測試(連續)
2.Intermittent life test 室溫壽命測試(間歇)
48 hours continuous operation at +55℃ with rated voltage applied.
在+55℃環境下,以額定電壓連續操作 48 小時.
A duty cycle of 1 minute on, 1 minutes off, a minimum of 5000 times at room
temp.( +25 ±2℃)and rated voltage applied.
在室溫下(+25 ±2℃), 以額定電壓操作, 通電 1 分鐘/斷電 1 分鐘,測試
5000 次循環.
After being placed in a chamber at +85℃ for 240 hours
置於+85℃環境中 240 小時
After being placed in a chamber at –40℃ for 240 hours
置於-40℃環境中 240 小時
After being placed in a chamber at +40℃ and 90±5% relative humidity
for 240 hours
置於+40℃, 相對濕度 90±5% 環境中 240 小時
The part shall be subjected to 5 cycles.
單體承受溫度循環測試 5 次.其循環內容如圖示.
:
:
:
:
a) Temperature : +5 ~ +35℃ b) Humidity : 45-85%
a) 溫度 : +5 ~ +35℃
a) Temperature : +25 ± 2℃
a) 溫度 : +25 ± 2℃
Test condition
Test Condition
b) 濕度 : 60-70%
b) Humidity : 60-70%
b) 濕度 : 45-85%
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
Being placed for 4 hours at
+25℃, buzzer shall be
measured. The value of
oscillation frequency/ current
consumption should be in ±10%
compared with initial ones .The
SPL should be in ±10dB
compared with initial one.
經測試後, 靜置於+25℃(室溫)
環境中 4 小時後
電流變化量須在±10%內. 輸出音
壓變化量須在±10dB 內.
Being placed for 4 hours at
+25℃, buzzer shall be
measured. The value of
oscillation frequency/ current
consumption should be in ±10%
compared with initial ones .The
SPL should be in ±10dB
compared with initial one.
經測試後, 靜置於+25℃(室溫)
環境中 4 小時後,諧振頻率與消耗
電流變化量須在±10%內. 輸出音
壓變化量須在±10dB 內.
Evaluation standard
Evaluation standard
,
諧振頻率與消耗

Related parts for KMTG1603