CS1W-DA041 Omron, CS1W-DA041 Datasheet - Page 32

no-image

CS1W-DA041

Manufacturer Part Number
CS1W-DA041
Description
MODULE,ANALOG OUT,4CH
Manufacturer
Omron
Datasheet

Specifications of CS1W-DA041

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Special I/O Modules
Customizable Counter Modules
J Specifications
C--104
All Modules:
CS1W-HIO01,
CS1W-HCP22, and
CS1W-HCA22
CS1W-HCP22
(pulse I/O)
CS1W-HCA22 (pulse
inputs and analog
outputs)
Model
Programmable Controller
Contact inputs
Contact outputs
Pulse inputs
(high-speed counters)
Pulse outputs
Pulse inputs
(high-speed counters)
Analog outputs
I/O
CS1
12 inputs (24-VDC; bits IR 00000 to IR 00011)
Details:
• 4 interrupt inputs in Input Interrupt Mode or Counter Mode. Can also be
• 8 normal inputs (bits IR 00004 to IR 00011)
Note
8 outputs (transistor NPN outputs; bits IR 00100 to IR 00107)
2 inputs
Each input can be set to either single-phase or differential-phase
(multiplication factor of 1, 2, or 4) at 50 or 200 kHz (switchable).
Note
2 outputs
Each output can be set to any one of the following:
1. Pulse output: 6 Hz to 200 kHz
2. One-shot pulse output: Output can be set to turn ON for a time specified
3. Pulse output counter timer (time measurement): High-precision timer
2 inputs
Each input can be set to either single-phase or differential-phase
(multiplication factor of 1, 2, or 4) at 50 or 200 kHz (switchable).
Note
2 outputs
Each output can be set to any one of the following: 1 to 5 V, 0 to 5 V, 0 to 10
V, or --10 to 10 V
Accuracy: ±0.3%; Resolution: 4,000 (1 to 5 V, 0 to 5 V, 0 to 10 V) or 10,000
(--10 to 10 V), D/A conversion time: 0.5 ms max.
Outputs the output values set in the AR Area. Also, for each point, using the
SPED instruction and ACC instruction (combined use possible), output at a
fixed analog value, or output at values rising or falling at a fixed rate, is
possible.
• It is possible to select either immediate refreshing when instructions are
• Analog output values can be held. (Analog values can be output at their
Note
used as normal inputs (bits IR 00000 to IR 00003)
executed or refreshing of output values in the AR Area after execution of
the END instruction as the refreshing method for analog output.
peak, held, or cleared values when the Conversion Enable Flag is OFF, a
fatal error occurs, or an analog output error occurs.)
by the user. (Set in range 0.01 to 9,999 ms in 0.01-ms Modules.)
measurement in 0.01-ms Modules is possible using one-shot pulse output.
(In this case, external pulse output is not possible.)
It is possible to specify ON, OFF, or both for the timing of interrupts
in Input Interrupt Mode.
Target value interrupts or range comparison bit pattern outputs for
high-speed counter present values can be programmed. Measure-
ment of the rate of change in high-speed counter present values and
measurement of the frequency from the high-speed counter present
values is also possible.
Target value interrupts or range comparison bit pattern outputs for
high-speed counter present values can be programmed. Measure-
ment of the rate of change in high-speed counter present values and
measurement of the frequency from the high-speed counter present
values is also possible.
It is also possible to produce trapezoidal output of analog values
according to the time elapsed by combining the SPED instruction,
the ACC instruction, timer instructions, and scheduled interrupts.
Contents

Related parts for CS1W-DA041