E5ZN-2QPH03TC-FLK Omron, E5ZN-2QPH03TC-FLK Datasheet - Page 7

DIN RAIL TC, VOLT OUT, T/C IN

E5ZN-2QPH03TC-FLK

Manufacturer Part Number
E5ZN-2QPH03TC-FLK
Description
DIN RAIL TC, VOLT OUT, T/C IN
Manufacturer
Omron
Series
E5ZNr
Type
Temperature Controller, Modularr
Datasheet

Specifications of E5ZN-2QPH03TC-FLK

Rohs Compliant
YES
Input Type
Thermocouple (Multiple)
Controller Type
On/Off or Proportional (PID)
Temperature Range
Selectable, Varies By Input Type
Output Type
Voltage
Supply Voltage
24VDC
Size
DIN Rail Module
Features
DIN Rail Mount
Communications
RS-485 (CompoWay/F)
Display Type
LED Lights
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E5ZN2QPH03TCFLK
Nomenclature
E5ZN-2
E5ZN-SDL
The following diagram shows the names and functions of the E5ZN-SDL parts for when it is connected to the E5ZN-2
• These indicators indicate the terminal
• OUT1, OUT2 (Control Output 1, Control
• SUB1, SUB2 (Auxiliary Output 1, Auxiliary
• STOP
• CMW (Communications Write Control)
• Some indicators are not used on the
operations for the E5ZN-2@@@@@@@.
Output 2)
Light when the control output 1 or the control
output 2 functions are ON.
Output 2)
Light when the auxiliary output 1 or the
auxiliary output 2 functions are ON.
Lights when operation stops. Lights for an
event or when RUN/STOP is set to STOP
during control. Remains unlit at other times.
Lights when communications write is permitted
and remains unlit when it is prohibited.
E5ZN-2@@@@@@@ (SUB3, SUB4).
POWER
Lights when power is turned ON.
ERROR
Lights when a fatal error (e.g., memory
error or sensor error) occurs.
SD/RD (Communications Operation)
Flashes during communications with the host.
OUT1 (Control Output 1)
Lights when the control output 1 is ON.
OUT2 (Control Output 2)
Lights when the control output 2 is ON.
SUB1 (Auxiliary Output 1)
Lights when the auxiliary output 1 is ON.
SUB2 (Auxiliary Output 2)
Lights when the auxiliary output 2 is ON.
Unit/Channel Indicator
Indicates the unit number and
the channel number.
Level Key
Press this key to switch setting
levels.
Mode Key
Press this key to switch setting
data within the setting level.
Operation Indicators
Operation Indicators
UNIT Key
Press to switch the unit number.
Level Key and Mode Key
Press together to switch to protect mode.
Temperature Unit
Displayed when the display unit for setting
data is temperature. The display is
determined by the setting for temperature unit,
with either “°C” or “°F” displayed accordingly.
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
Unit Number Setting
Setting range of 0 to F allows up
to 16 Units to be set.
Baud Rate
No. 1 Display
Displays the PV or the type of
setting data.
No. 2 Display
Displays the target value, the
control variable, or the set value
for setting data (setting contents).
Up Key
Each time this key is pressed, the
value displayed in No. 2
Display increases. If it is held
down, the rate of increase
becomes faster.
It can also be used to move to the
next setting item.
Down Key
Each time this key is pressed, the
value displayed in No. 2
Display decreases. If it is held
down, the rate of decrease
becomes faster.
It can also be used to return to the
previous setting item.
Channel Key
Press this key to change the
channel number.
Copy Key
Press this key to read all the
settings from the Temperature
Controller to the Setting Display
Unit, or to write from the Setting
Display Unit to the Temperature
Controller.
@@@@@@@
.
E5ZN
7