E2E-X10MF1 Omron, E2E-X10MF1 Datasheet - Page 38

Inductive Proximity Sensor

E2E-X10MF1

Manufacturer Part Number
E2E-X10MF1
Description
Inductive Proximity Sensor
Manufacturer
Omron
Series
E2Er
Datasheets

Specifications of E2E-X10MF1

Sensor Input
Inductive
Sensing Range
10 Mm
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
10mm
Switch Terminals
Connector
Supply Voltage Max
30VDC
Supply Voltage Min
10VDC
Maximum Operating Temperature
+ 85 C
Supply Voltage
10 V to 40 V
Operating Supply Voltage
10 V to 40 V
Mounting Style
Panel
Sensing Distance
10 mm
Minimum Operating Temperature
- 40 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
200Hz
Material - Body
Nickel-Plated Brass
Shielding
Unshielded
Voltage - Supply
10 V ~ 30 V
Output Type
PNP-NO
Terminal Type
3-Wire
Package / Case
Cylinder, Threaded - M18
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
38
AC 2-wire
DC 3-wire
Model
OR
(parallel connection)
AND (serial connection)
E2E/E2E2
Connection type
Cylindrical Proximity Sensor
A
A
B
B
Correct
Incorrect
Correct
Method
Load
Load
Load
VAC power
supply V
S
In principle, more than two Proximity Sensors cannot
be connected in parallel.
Provided that Proximity Sensor A does not operate
with Proximity Sensor B simultaneously and there is
no need to keep the load operating continuously, the
Proximity Sensors can be connected in parallel. In
this case, however, due to the total leakage current
of the Proximity Sensors, the load may not reset
properly.
It is not possible to keep the load operating
continuously with Proximity Sensors A and B in
simultaneous operation to sense sensing objects
due to the following reason.
When Proximity Sensor A is ON, the voltage
imposed on Proximity Sensor A will drop to
approximately 10 V and the load current flows into
Proximity Sensor A, and when one of the sensing
objects is close to Proximity Sensor B, Proximity
Sensor B will not operate because the voltage
imposed on Proximity Sensor B is 10 V, which is too
low. When Proximity Sensor A is OFF, the voltage
imposed on Proximity Sensor B will reach the supply
voltage and Proximity Sensor B will be ON. Then,
Proximity Sensor A as well as Proximity Sensor B
will be OFF for approximately 10 ms, which resets
the load for an instant. To prevent the instantaneous
resetting of the load, use a relay as shown on the left.
The Sensors connected together must satisfy the
following conditions.
i
Sensor
V
N: No. of Sensors
V
V
i: Current consumption of the Sensor
i
If the MY Relay, which operates at 24 VDC, is used
as a load for example, a maximum of two Proximity
Sensors can be connected to the load.
L
L
: Load current
S
R
S
+ (N –1) x i ≤ Upper-limit of control output of each
: Supply voltage
: Residual voltage of each Sensor
– N x V
R
≥ Load operating voltage
Description

Related parts for E2E-X10MF1