ZEN-20C3AR-A-V2 Omron, ZEN-20C3AR-A-V2 Datasheet - Page 19

Programmble Controller Relay

ZEN-20C3AR-A-V2

Manufacturer Part Number
ZEN-20C3AR-A-V2
Description
Programmble Controller Relay
Manufacturer
Omron
Datasheet

Specifications of ZEN-20C3AR-A-V2

Signal Input Type
100-240VAC
Output Type
Relay
External Width
122.5mm
Supply Voltage Max
240VAC
External Depth
44mm
External Height
80mm
Supply Voltage Min
100VAC
Approval Bodies
CURus, CE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operation
■ Bits
Note: 1. For details, refer to the indicated item numbers on the following pages.
1.
Input bits
Expansion input bits
Output bits
Expansion output bits
Work bits
Holding bits
Timers
Holding timers
Counters
8-digit counter
Weekly timers
(See note 3.)
Calendar timers
(See note 3.)
Display bits
(See note 3.)
Analog comparator bits A
Timer/counter
comparator bits
8-digit counter
comparator bits
Button input bits
(See note 3.)
Q0 will turn ON or OFF depending
on the ON/OFF status of the
execution condition I0.
Additional Bit Output Functions
Q0
I0
2. CPU Units with 10 I/O points have 6 input bits (I0 to I5) and 4 output bits (Q0 to Q3). Output bit Q3 of Communications-type CPU Units,
3. These input bits are not supported by LED-type CPU Units without display.
I0
Name
however, cannot be output externally. It can be used as a work bit.
[: Normal
I
X
Q
Y
M
H
T
#
C
F
@
*
D
P
G
B
Symbol
[Q0
I0 to Ib
(See note 2.)
X0 to Xb
Q0 to Q7
(See note 2.)
Y0 to Yb
M0 to Mf
H0 to Hf
T0 to Tf
#0 to #7
C0 to Cf
F0
@0 to @f
*0 to *f
D0 to Df
A0 to A3
P0 to Pf
G0 to G3
B0 to B7
addresses
Q1 will stay ON once the execution
condition I1 has turned ON once. A
reset is used to turn Q1 OFF.
Bit
Q1
I1
I1
points
12
12
8
12
16
16
16
8
16
1
16
16
16
4
16
4
8
No. of
S: Set
Reflect the ON/OFF status of the input devices connected to the input
terminals on the CPU Unit.
Reflect the ON/OFF status of the input devices connected to the input
terminals on the Expansion I/O Units.
The ON/OFF status of these output bits is used to control the output devices
connected to the output terminals on the CPU Unit.
The ON/OFF status of these output bits is used to control the output devices
connected to the output terminals on the Expansion I/O Units.
Work bits can be used only within the ZEN program. I/Os for external devices
cannot be made (i.e., all I/O is internal).
Used the same as the work bits. However, if the power to the ZEN is turned
OFF, these bits also maintain the previous ON/OFF status.
X: ON-delay timer
■: OFF-delay timer
O: One-shot pulse
F: Flashing pulse
W: Twin timer
Hold the present value being counted even if the trigger input or power supply
is turned OFF and continue timing when the trigger input or power is restored.
Reversible 4-digit counters that can be incremented and decremented.
Reversible 8-digit counters that can be incremented and decremented.
CPU Units with DC power supply support a high-speed counter up to 150 Hz.
For details, refer to 8-digit Counter Operation on page 21.
Turn ON and OFF during specified times on specified days.
Turn ON and OFF between specified dates.
Display user-specified messages, times, timer/counter present values, or
analog-converted values.
Used as program input conditions to output analog comparator comparison
results. These bits can be used only for CPU Units with DC power supply.
Compare the present values of timers (T), holding timers (#), and counters
(C). Comparison can be made between the same two counters or timers, or
with constants.
Used to compare the present values of 8-digit counters (F) and output the
comparison results.
Used as program input conditions and turn ON when operation buttons are
pressed in RUN Mode.
timer
timer
Set/Reset operation
SQ1
Q1 is forced OFF when the
execution condition I2 is turned
ON.
Q1
I2
Functions are
selected from the
screen when
parameter settings
are made.
I2
R: Reset
Operation
RQ1
Time units can be selected
from the following:
0.01-s unit: 0.01 to 99.99 s
min/s unit: 00 min 01 s to
h/s unit:
Q2 alternates between turning ON
and OFF when the execution
condition I3 turns ON.
Q2
I3
99 min 59 s
00 h 01 min to
99 h 59 min
ZEN V2 Units
I3
A: Alternate
note 1.)
AQ2
Details
(See
10
11
12
---
1
2
3
4
5
6
7
8
9
19