AZ7110 PANASONIC EW, AZ7110 Datasheet

LIMIT SWITCH, PUSH PLUNGER, SPDT

AZ7110

Manufacturer Part Number
AZ7110
Description
LIMIT SWITCH, PUSH PLUNGER, SPDT
Manufacturer
PANASONIC EW
Datasheet

Specifications of AZ7110

Actuator Style
Push Plunger
Operating Force Max
5.88N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
115V
Contact Current Ac Max
10A
Contact Current Dc Max
400mA
Switch Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AZ7110
Quantity:
160
Please contact ..........
ARCT1B272E 200609-1YT
Specifications are subject to change without notice.
These materials are printed on ECF pulp.
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
All Rights Reserved © 2006 COPYRIGHT Matsushita Electric Works, Ltd.
Matsushita Electric Works, Ltd.
Automation Controls Business Unit
http://www.nais-e.com/
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
Telephone: +81-6-6908-1050
Facsimile: +81-6-6908-5781
Printed in Japan.
Limit Switches
Limit Switches
ARCT1B272E ’06.9
Matsushita Electric Works, Ltd.
’06–’07

Related parts for AZ7110

AZ7110 Summary of contents

Page 1

These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 http://www.nais-e.com/ All ...

Page 2

... An M4 bolt can be used for the attachment. 3. The overtravel (O.T.) is large with great shock absorption 2. Terminal mold type (epoxy-sealed terminal type) Part No. AZ7100 Actuator AZ7110 AZ7120 Short push plunger AZ7121 Push plunger AZ7124 Hinge lever AZ7140 Roller lever ...

Page 3

ML (AZ7) FOREIGN STANDARDS Standards UL C-UL TÜV SPECIFICATIONS 1. Rating Rated control voltage 125V AC 250V AC 115V DC 2.Characteristics Contact arrangement Initial contact resistance, max. Contact material Initial insulation resistance (At 500V DC) Initial breakdown voltage In the ...

Page 4

... F. 2.0 ( O.P. ) 2.244 .079 50 2.0 1.969 .079 17 0.8 .669 .031 4.2 0.2 dia. 21.4 .843 ML (AZ7) AZ7110 ( P. max. 23.3 0.3 .917 .012 .079 ( O. 1.2 16 dia. 1.732 .047 ( 25 ) .630 ( .984 ) 17 0.8 .669 .031 4.2 0.2 dia. 25.4 0.15 14 ...

Page 5

ML (AZ7) • Short roller lever AZ7141 30.2 1.0 1.189 .039 25.4 0.15 1 inch 54 0.2 2.126 .008 16.5 max. .650 • Panel mount push plunger AZ7310 23.3 0.5 .917 .020 M12 ( P=1.0 ) 2-panel mounting nut Thickness ...

Page 6

Terminal Mold Type (Epoxy-Sealed Terminal Type) The waterproof type (IP64) has its terminals sealed with epoxy resin. 1. Type of product All the standard type have this epoxy-sealed terminal types. 2. Appearance The dimensions are the same as those of ...

Page 7

SELECTOR CHART Classification Subminiature size SL (AZ3) Micro Product name Limit Switches Appearance Head code AZ3 • A limit switch with • High sealability that high-density mounting that improves stroke • Wiring is screw-ter- capacity through an Feature O.T. absorption-type ...

Page 8

Subminiature size Classification vertical type QL (AZ4) Micro DL (AZD1) Mini Product name Limit Switches Limit Switches Appearance Head code AZ4 • A subminiature, highly accu- • Excellent safety even if the rate limit switch with built-in contact point is ...

Page 9

ACTUATOR SELECTION Pretravel Type Classification Push plunger type Roller plunger type (includes cross roller plunger) Small to Roller arm type Adjustable roller Small to arm type Adjustable rod type Fork Spring wire and Medium flexible rod Hinge lever type Roller ...

Page 10

TECHNICAL INFORMATION Standard glossary • Fixed rating values The values that guarantee the stan- dards for the limit switch characteris- tics and functions. For example, the rated current and rated voltage, which are preset conditions (load type, current, voltage, frequency, ...

Page 11

TECHNICAL INFORMATION Glossary relating to the EN60947-5-1 • EN60947-5-1 EN standard same as IEC947-5-1 • Utilization categories The following examples express the classification of switches by category of use. Current Category Contents type Controls electromagnetic AC AC-15 loads in excess ...

Page 12

PROTECTIVE CONSTRUCTION Protective construction Expresses the degree of protective construction that guards the level of functionability of the switch against ingress of solid objects, water, and oil. The standards are IEC529 (IEC: International Electrotechnical Commission) standards. IEC standards determine the ...

Page 13

CAUTIONS FOR USE DESIGN OF OPERATING DOG AND OPERATING SPEED Pay attention to the following points when designing the dog for limit switch operation. 1. Make the dog faceplate as smooth as possible. 2. Adjust both the dog angle and ...

Page 14

PROTECTION CIRCUIT 1. The ON/OFF circuit for the guidance load may suffer contact damage due to surges or inrushes when the power is turned either ON or OFF. Consequently, insertion of a protective circuit as per the following diagram is ...

Page 15

CAUTIONS FOR USE CAUTIONS FOR USE 1) Do not attempt to physically alter any part of the switch itself, such as the actuator, or switch attachment vent, as this may cause alterations to both characteristics and performance, and damage the ...

Page 16

IMPROVEMENT EXAMPLES Poor design @ @ Dog axle @ Detector Printer Conveyer @ @ Limit @ @ @ High temperature Improved design r r Detector r Rotation axle Conveyer r Rotation axle r Protective cover High temperature ...

Page 17

IMPROVEMENT EXAMPLES Poor design @ Detector Dumper Conveyer @ Conveyer Detector @ Dog @ 12 Improved design r Rotation axle r Conveyer Detector r r Explanation Problem • The detector is scratched. • Limit attachment adjustments are difficult • The ...

Page 18

Table of Recommended Substitute Products for Discontinued Products Products to be discontinued AZ1 series Limit switches AZ2 series Limit switches Slitted type Limit switches (AZ6) New slitted type Limit switches (AZ66) Products to be discontinued You cannot use this nut ...

Page 19

FOREIGN STANDARDS OVERVIEW 1. International Standards IEC standard International Electrotechnical Commission By promoting international cooperation toward all problems and related issues regarding standardization in the electrical and electronic technology fields, the IEC, a non-governmental organization, was started in October, 1908, ...

Page 20

SAFETY STANDARDS RECOGNITION Limit switches Product name SL limit switches Dies-cast case standard load type Die-cast case low level load type HL limit (includes connector type) switches Plastic case standard load type Plastic case low level load type Standard type ...

Related keywords