F3SNA0307P25 Omron, F3SNA0307P25 Datasheet - Page 13

Safety Light Curtain

F3SNA0307P25

Manufacturer Part Number
F3SNA0307P25
Description
Safety Light Curtain
Manufacturer
Omron
Datasheet

Specifications of F3SNA0307P25

Beam Spacing
15mm
Control Output Type
PNP
No. Of Beams
19
Protection Height
307mm
Sensing Range Max
10m
Supply Voltage Max
24VDC
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Connections
Wiring for Sensor Only Configuration
Wiring for the Manual Reset Mode and the EDM Function
Series Connection (Up to 3 Sets)
Using series connection models (model numbers ending in -01, -03,
-04, -05) enables series connection as shown in the figure at the right.
Either stand-alone models and the series connection models can be
used for the light curtains located at the top end.
Note: 1. To maintain performance characteristics, use the F39-
Emitter cable
F39-JC@A-L
2. The F3SN and F3SH cannot be connected in series.
3. Series connection is possible for model numbers ending in
(See
note 1.)
S1
JCR2B or the F39-JC3B to connect light curtains in series.
The F39-JC7B, F39-JC10B, or F39-JC15B cannot be
connected in series.
-04 or -05 (with 0.2 m cable with connectors).
Refer to page 2.
(See
note 1.)
S2
Emitter
http://www.ia.omron.com/
RS-485(A) (Gray)
RS-485(B) (Pink)
Receiver
K1
K2
K3
Receiver cable
F39-JC@A-D
K1
K2
+24 VDC
0 V
Power
supply
Wiring for the Auto-reset Mode
When the EDM is Not Used
When the EDM is not necessary
(1) Use the F39-MC11 to disable the EDM.
or
(2) Disable the EDM by changing the wiring as shown in the
Note: 1. Use very low load type switches.
S1:
S2:
S3:
K1, K2: Relay that control the dangerous zone, etc.
K3:
figure below, when the auxiliary output is Dark ON.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Emitter
Emitter
Cable with Connectors
on Both Ends (for Emitter)
F39-JCR2B-L,
F39-JCR5B-L,
or
F39-JC3B-L
Cable with Connector
on One End
(for Emitter)
F39-JC@A-L
2. If K3 is not necessary, short-circuit the auxiliary
(See notes 1 and 3.)
External test switch
Interlock/lockout reset switch
Lockout reset switch (If the switch is not necessary,
connect between the reset input and +24 VDC.)
Load, PLC, etc. (used for monitoring)
(See
note 1.)
output with the EDM input.
S1
Emitter
(See
note 1.)
S3
F3SN-A/F3SN-B/F3SH-A
Receiver
F3SN-A@@@@P@@(-@@)*
Receiver
F3SN-A@@@@P@@-01
(or -03, -04, -05) *
Cable with Connectors
on Both Ends (for Receiver)
F39-JCR2B-D,
F39-JCR5B-D,
or
F39-JC3B-D
(See notes 1 and 3.)
Cable with Connector
on One End
(for Receiver)
F39-JC@A-D
(See note 2.)
Receiver
K3
K1
* Series connection is
possible for the F3SN-B.
13