HS5E-B7Y403-G IDEC, HS5E-B7Y403-G Datasheet - Page 3

SWITCH, SAFETY INTERLOCK, 2NC, 2A

HS5E-B7Y403-G

Manufacturer Part Number
HS5E-B7Y403-G
Description
SWITCH, SAFETY INTERLOCK, 2NC, 2A
Manufacturer
IDEC
Series
HS5Er
Datasheet

Specifications of HS5E-B7Y403-G

Contact Voltage Ac Max
125V
Contact Voltage Dc Max
30V
Contact Current Ac Max
2A
Contact Current Dc Max
2A
Switch Terminals
Cable
Contact Configuration
SPST-NC / SPST-NC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
378
Interlock Switch Status
Door Status
Circuit Diagram (Example: HS5E-A4)
Door
Solenoid Power A1-A2 (all types)
Door
Solenoid Power A1-A2 (all types)
Operating Characteristics
(reference)
Main Circuit
Monitor Circuit (door open, NO)
Monitor Circuit (door closed, NC)
Monitor Circuit (Unlocked, NO)
Monitor Circuit (Locked, NC)
HS5E-A4
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E-B4
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E-D4
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E-A7Y
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E-B7Y
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E-D7Y
Main Circuit:
Monitor Circuit:
Monitor Circuit:
1. Main circuit: Connected to the control circuit of machine drive part, sending the interlock signals to the protective door.
2. Monitor circuit: Sends ON/OFF signals of main circuit and monitoring signals of open/closed status of protective door.
3. Do not attempt manual unlock when energized.
4. Do not energize the solenoid for a prolonged period of time when the door is open and when unlocking the door manually.
23
23
21
23
23
21
11
11
11
11
11
11
12
24
12
24
12
22
12
24
12
24
12
22
HS5E Series
0
(Key Insertion Position)
41
53
41
51
41
51
41
53
41
51
41
51
3.3 (Locked position)
(+)
(+)
A2
A2
5.3 6.9
42
54
42
52
42
52
42
54
42
52
42
52
(–)
A1
(–)
A1
Main Circuit 11-42
Monitor Circuit
(door open) 23-24
Monitor Circuit
(unlocked) 53-54
Main Circuit 11-42
Monitor Circuit
(door open) 23-24
Monitor Circuit
(unlocked) 51-52
Main Circuit 11-42
Monitor Circuit
(door open) 21-22
Monitor Circuit
(unlocked) 51-52
Main Circuit 11-42
Monitor Circuit
(door open) 23-24
Monitor Circuit
(unlocked) 53-54
Main Circuit 11-42
Monitor Circuit
(door open) 23-24
Monitor Circuit
(locked) 51-52
Main Circuit 11-42
Monitor Circuit
(door open) 21-22
Monitor Circuit
(locked) 51-52
26.4
(stroke in mm)
Contacts ON (closed)
Contacts OFF (open)
Door closed
Machine ready to
operate
Solenoid de-energized
11
23
OFF (de-energized)
Closed (locked)
Closed (locked)
ON (energized)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
Status 1
12
24
(+)
A2
41
53
Circuit Diagrams
42
54
(–)
A1
www.idec.com
Door opened
Machine cannot be
operated
Solenoid energized
Closed (unlocked)
Closed (unlocked)
11
23
OFF (de-energized)
ON (energized)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
Status 2
12
24
The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A65, and -A66 actuators. For the
The characteristics show the contact status when the actuator enters an entry slot of an interlock switch.
HS9Z-A62S actuator, subtract 0.6 mm.
(+)
A2
41
53
42
54
(–)
A1
Door open
Machine cannot be
operated
Solenoid energized
OFF (de-energized)
ON (energized)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
Status 3
Open
Open
11
23
12
24
(+)
A2
41
53
ON (energized) (note 4)
Door open
Machine cannot be
operated
Solenoid de-energized
OFF (de-energized)
Door Interlock Switches
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
42
54
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
(–)
A1
Status 4
Open
Open
Manual Unlock Key
OFF (de-energized) to
Door closed
Machine cannot be
operated
Solenoid de-energized
Closed (unlocked)
Closed (unlocked)
11
23
ON (energized) (see
note 3) (see note 4)
Unlocking Using
OFF (de-energized)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
12
24
Locked
Manual Unlocking
(+)
A2
41
53
Unlocked
42
54
(–)
A1

Related parts for HS5E-B7Y403-G