101 013 SJSJ YOKOGAWA, 101 013 SJSJ Datasheet - Page 18

Voltage Meter

101 013 SJSJ

Manufacturer Part Number
101 013 SJSJ
Description
Voltage Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 101 013 SJSJ

Meter Function
DC Voltmeter
Meter Range
0-600 V
Meter Size/dimensions
DB-14
Scale Length
6.9"
Meter Shape
Square
Voltage Meter Range
0-600 VDC
Display Accuracy ±
1%
Accuracy
+/- 1% Of FS
Barrel Size
3.97"
Meter Movement
Moving Coil
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Optional Features for AB/DB 40, AB/DB 16
Scales
Ratings and Calibration
11. Special calibration in accordance
13. Terminal resistance and/or toler-
14. Special sensitivities for DC taut-
15. Special frequency calibration
10. Offset-zero scale — Available for
12. Calibration at any angle other
1. Uncalibrated
2. Special marked scales
3. Special legends
4. Colored markings, lines or arcs
5. Fine line marking (approximately
6. Black scale — white markings
7. a) Double set of numbers —
8. a) Double set of numbers —
9. Zero-center scales —
other than black.
twice the normal calibration marks
— maximum 150 calibration marks
b) Triple set of numbers —
b) Triple set of numbers —
DC ammeters, DC milliammeters,
DC voltmeters, AC wattmeters and
varmeters. Not available for AC
ammeters, voltmeters
varmeters, AC wattmeters, DC
ammeters and DC voltmeters
with data supplied by customers
than vertical — Specify angle.
Note: DC instruments can be used
up to a 30° tilt from vertical with-
out additional error
ance other than standard
tolerance (±15%)
band voltmeters. Standard
sensitivities are:
zero-left: 1000 ohms/volts
zero-center: 2000 ohms/volts
a) Any frequency 25 to 400 Hertz.
b) Over 400 Hertz, consult factory.
Note: Does not apply to tempera-
ture indicators
Single set of divisions
Single set of divisions
Double set of divisions
Double set of divisions
16. Double-rated voltmeters and
17. Wattmeters & varmeters with cur-
18. Accuracy other than listed
19. Suppressed zero — Maximum
The words “Spindle,” “Table,” “Roll,” “Motor,” “Turbine” can be added to the above at no extra cost.
Also, when necessary, the multipliers, “X-10,” “X-100,” or “X-1000” will be added to these legends.
Standard Scale Legends
AC Volts or Kilovolts
AC Amperes, or Kiloamperes
AC Watts, Kilowatts or Megawatts
Vars, Kilovars or Megavars
Synchroscope
Power Factor
Hertz
Phase Angle
DC Volts, or Kilovolts
DC Watts or Kilowatts
Percent-Motor-Load Current
Percent Horsepower
Degrees C
Degrees F
Degrees K
Degrees R
Kilo-Ohms
Horsepower
Percent
Percent Load
VA. In HG
ammeters (includes double-
marked scale if required). Double
ratings should be chosen to allow
a single set of divisions whenever
possible. AC ammeters can have
double rating only when one cur-
rent is double the other (e.g., 2.5/5
amperes)
rent coils rated other than 5
amperes.
suppression 20% of scale.
Double-rated DC ammeters are
not recommended
or Milliamperes
S W I T C H B O A R D I N S T R U M E N T S
% KW
Hz
FPS
KPS
YPS
CPM
FPM
IPM
KPM
RPM
YPM
CPH
FPH
IPH
KPH
MPH
RPH
YPH
PPH
PSI
Construction
26. Component mark for Canada. Add
20. Weathertight case (standard on
21. Red manual-set pointer(s) 1 or 2
22. Anti-glare window AB/DB-40 only
23. Wooden-box packaging for export
24. Tagging Dymotape or Paper
25. Optional extra-short case (overall
metal case AB/DB-40, no adder.
Not available on AB/DB-16 models)
(AB/DB-40 only). Adjustable over
entire scale from the front of the
instrument
shipping
depth 3.41") for metal case amps
and volts only.
“/CSA” to suffix of catalog number.
LBS
PSIG
GPH
PSIA
IPS
PPS
RPM
GPM
In. H
2
O
17

Related parts for 101 013 SJSJ