101-113-KMKM YOKOGAWA, 101-113-KMKM Datasheet - Page 28

Current Meter

101-113-KMKM

Manufacturer Part Number
101-113-KMKM
Description
Current Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 101-113-KMKM

Meter Function
DC Milliammeter
Meter Range
0-500 MADC
Meter Size/dimensions
AB-14
Scale Length
6.9"
Meter Shape
Square
Display Accuracy ±
1%
Current Meter Range
0-500 MADC
Accuracy
+/- 1% Of FS
Barrel Size
3.97"
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Dimensions and Panel Cutout
Type 180 Optional Features
Scale Variations
Ratings and Calibration
10. Calibration for use on other than vertical panel
11. Calibration for use on 400 Hertz or other unlist-
12. High-sensitivity voltmeters
13. Special-terminal resistance
14. Internal mounted rheostat
15. Rectifier-type voltmeters 2.5 percent.
16. 1 percent accuracy (DC only)
17. Suppressed zero with operable zero set (DC
1. Blank Scales
2. Special marked scales (maximum 100 divisions;
3. Special Legends (Ref. Notes 3 and 4)
4. Colored markings, lines, bars, etc.
5. Black scale with white markings
6. Zero-center Scale DC instruments
7. Unlisted ratings. Contact factory for other than
8. Offset-zero scale (DC meters only)
9. Special calibrations in accordance with data
D
Ref. Notes 3 and 4)
listed ratings.
supplied by customer
ed frequency.
(See Note 2)
only) (See Note 1)
IMENSIONS FOR
DWG B3147K22
T
YPE
180 I
NSTRUMENTS
Construction
18. Internal illumination
19. Red pointer (Day-glo)
20. Anti-glare window
21. Black trim case
22. Component mark for Canada. Add “/CSA” to
Notes:
1. Suppressed zero — Available only on DC mod-
2. High-sensitivity voltmeters — DC voltmeters can
3. Special legends and/or scales may be obtained
els up to a maximum suppression of 20 percent
of full-scale value. Note: Accuracy is affected on
suppressed-zero instruments.
be offered up to 20,000 ohms/volt. Voltmeters
of high sensitivity draw less current from the
circuit and are used on applications where the
circuit current is so low that instrument resis-
tance will appreciably affect circuit operation.
by special order. Maximum number of letters
(counting spaces as letters) on vertical instru-
ments is 25; on horizontal instruments, 30.
Exact wording must be clearly indicated as to
spelling, abbreviation, spacing, etc.
suffix of catalog number.
S W I T C H B O A R D I N S T R U M E N T S
4. Type 180 scales and legends are individual parts
5. No charge for electrical legends.
separated by a space for the pointer. Only one
set of divisions can be marked on a scale.
27