103 131 LALA YOKOGAWA, 103 131 LALA Datasheet - Page 32

Current Meter

103 131 LALA

Manufacturer Part Number
103 131 LALA
Description
Current Meter
Manufacturer
YOKOGAWA
Datasheet

Specifications of 103 131 LALA

Meter Function
AC Ammeter
Meter Range
0-1 A
Meter Size/dimensions
AB-40
Scale Length
6.9"
Meter Shape
Square
Display Accuracy ±
1%
Current Meter Range
0-1 AAC
Accuracy
+/- 1% Of FS
Barrel Size
3.97"
Meter Movement
Moving Coil
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
GENERAL SPECIFICATIONS — POWER SERIES
NOTE: POWER SERIES
DISPLAY
AUXILIARY
POWER
INPUT
RATING
INPUT RANGE
SUSTAINED
INPUT
BURDEN
ACCURACY
ANALOG OUTPUT
RESPONSE TIME
OUTPUT RIPPLE
ISOLATION
VOLTAGE /
INSULATION
RESISTANCE
TEMPERATURE
RANGE
TEMPERATURE
COEFFICIENT
EXTERNAL
INFLUENCE
SURGE WITH-
STAND VOLTAGE
DIMENSIONS
WEIGHT
DESIGN
STANDARDS
AND
Please call 1-800-258-2552 ext 575 for the latest catalog information.
Plus
Digital Switchboard capability is continually being expanded. Now available: Dual function & communications.
Type:
Digit height:
Decimal points:
Out of range indication:
Response time:
Choice of inputs at
rear terminal board
Current:
Voltage:
Frequency:
Rated current:
Rated voltage:
Rated current:
Rated voltage:
Current:
Voltage:
Reference condition:
25ºC, 45-74%RH, at
rated input 60Hz sine
wave, 30 min. warmup
0 to 1mA, 0 to ± 1mA:
4 to 20mA, 12 ± 8mA:
Input to output/case:
Aux. power to case:
Aux. power to output:
Output to case:
Operating:
Storage:
Magnetic field:
Shock / vibration:
SWC tests:
Reference Page 32
3
4
0.56 inch or 14mm
3 or 4 position selectable during scaling setup
Flashing display “HHHH” for high and ”LLLL” for low
200 millisecond maximum update time
120 or 240 VAC (±15%), 45-65Hz
Power consumption-4.5 VA maximum
0 to 1 AAC; 0 to 5AAC
0-120VAC, 0-240 VAC (W/VAR/PF/PA); 0-150VAC, 0-300VAC (Volt / Freq)
50/60 Hz and 400 Hz
A / W / VAR: 0-200% ; PF / PA: 20-200%
V / W / VAR: 0-120% ; PF / PA: 50-120%; Frequency: 20-120%
A / W / VAR / PF / PA: 200% continuous, 10 x rating for 5 seconds
V / W / VAR / FREQ: 120% continuous; PF / PA: 150% continuous
<0.2 VA per element
120V: <0.2VA per element; 240V: <0.4 VA per element
Voltage
Current
Watt/VAR
Power Factor
Phase Angle
Frequency
10VDC compliance into 10k ohm load maximum
15VDC compliance into 750 ohm load maximum
1 second maximum response time within ±1% of final value
0.5% peak-to-peak maximum of output span
2500 VAC for 1 minute / more than 10 Megohm @ 500VDC
2000 VAC to 1 minute / more than 10 Megohm @ 500VDC
2000 VAC for 1 minute / more than 10 Megohm @500VDC
1000 VAC for 1 minute / more than 10 Megohm @ 500VDC
-20 to +60º C at 90% RH maximum (non-condensing)
-40 to +85º C
150 PPM / ºC maximum of full scale
0.5% maximum at 400 ampere turns/meter
<0.2% after: 50G x 3axis x 6 repetitions / 16.7Hz, 4 mm p-p for 1 hour
Meets IEEE 472 / ANSI C37.90a
Meets JIS C1111 (5kV 1.2 x 50 microseconds)
W x D x H = 4.33 x 6.54 x 4.33 inches
Approximately 1000 grams (2.2 lbs)
ANSI C39.1
UL Recognition (pending)
1
1
2
2
digit Red LED for Power Factor and Phase Angle
digit Red LED for Amps/ Volts/ Watts/ VARS/ Frequency
S W I T C H B O A R D I N S T R U M E N T S
Plus
± 0.2% of reading ± 0.1% of full scale
± 0.05 Power factor
± 0.5º Phase Angle
± 0.01Hz @ 40-70Hz, ±0.1 Hz @ 300-500 Hz
31