K3HBRNB 100/240VAC Omron, K3HBRNB 100/240VAC Datasheet - Page 10

METER, RATE, V/NV/NPN, 100/240AC

K3HBRNB 100/240VAC

Manufacturer Part Number
K3HBRNB 100/240VAC
Description
METER, RATE, V/NV/NPN, 100/240AC
Manufacturer
Omron
Datasheet

Specifications of K3HBRNB 100/240VAC

No. Of Digits / Alpha
5
Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Approval Bodies
CE, CRUus, UL
Display
Backlit LCD Display
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digital Time Interval Meter for Measuring
Passing Speed, Time, or Cycle between Two
Points.
• Measures Wide Range of Pulse Interval Times
• Six Measurement Operations, Including Passing Speed, Time,
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
1. Input Sensor Codes
5. Supply Voltage
Optional Board
Sensor Power Supply/Output Boards
Relay/Transistor Output Boards
Event Input Boards
Note: 1. CPA can be combined with relay outputs only.
Accessories (Sold Separately)
10
K3HB-P @
K33-@
K34-@
K35-@
and Cycle Measurement between Two Points
Measures, calculates, and displays pulse intervals between two
points. Wide range for pulse interval measurements, from 10 ms to
3,200 s, max.
One Digital Time Interval Meter has six measurement functions, to
support a variety of pulse interval measurement applications. Select
the best function for your application from the following: Passing
speed, cycle, time difference, time band, measuring length, and
interval.
Timer Interval Indicator
K3HB-P
NB: NPN input/voltage pulse input
PB: PNP input
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
2. Only one of the following can be used by each Digital Indicator:
Refer to Common Precautions on page 30.
2
3
4
RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
1
Timer Interval Indicator
5
K3HB-P
Base Units with Optional Boards
2. Sensor Power Supply/Output Type Codes
3. Relay/Transistor Output Type Codes
4. Event input Type Codes
K3HB-P@-@@@
None:
CPA:
L1A:
L2A:
A:
FLK1A: Communications (RS-232C) + Sensor power supply
FLK3A: Communications (RS-485) + Sensor power supply
None: None
C1:
C2:
T1:
T2:
BCD: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
None: None
1:
2:
3:
4:
Relay contact (H/L: SPDT each)
Relay contact (HH/H/LL/L: SPST-NO each)
Transistor (NPN open collector: HH/H/PASS/L/LL)
Transistor (PNP open collector: HH/H/PASS/L/LL)
5 points (M3 terminal blocks) NPN open collector
8 points (10-pin MIL connector) NPN open collector
5 points (M3 terminal blocks) PNP open collector
8 points (10-pin MIL connector) PNP open collector
None
Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
Linear current output (DC0(4)-20 mA) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Linear voltage output (DC0(1)-5 V, 0 to 10 V) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Sensor power supply (12 VDC ±10%, 80 mA)
(12 VDC±10%, 80 mA) (See note 2.)
(12 VDC±10%, 80 mA) (See note 2.)
1
2 3 4
5