SNAP-RACKDIN OPTO 22, SNAP-RACKDIN Datasheet

SNAP Rack DIN-rail Adapter Clip

SNAP-RACKDIN

Manufacturer Part Number
SNAP-RACKDIN
Description
SNAP Rack DIN-rail Adapter Clip
Manufacturer
OPTO 22
Type
Mounting Racksr
Datasheets

Specifications of SNAP-RACKDIN

Peak Reflow Compatible (260 C)
No
Mounting Type
Snap Rack Mount
Number Of Pins
50-Pin
Number Of Positions
2
Standards
UL Listed, CSA Certified
Terminal Type
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SNAP B-Series Racks
Description
NOTE: For racks to use with SNAP PAC controllers and brains, see
Opto 22 form #1684, the SNAP PAC Racks Data Sheet.
NOTE: M-series racks (such as the SNAP-M64), used with SNAP
Simple brains and SNAP-UP1-M64 controllers, have been replaced
by SNAP PAC racks. See form #1684.
SNAP B-series mounting racks are designed to hold an intelligent
SNAP I/O processor—either a SNAP brain or an on-the-rack
controller—and several I/O modules.
This rack family includes racks that are compatible with ARCNET
and serial SNAP brains, including those using Modbus
Profibus
I/O™ on-the-rack controllers and SNAP Ethernet I/O™ brains. For
specific processor compatibility, see
Since SNAP analog, digital, and serial I/O modules have the same
footprint, customers using most SNAP B-series racks can mix
modules on the same I/O mounting rack. However, module types,
features, and positions on the rack vary depending on the
capabilities of the brain or on-the-rack controller used. See the
brain or controller data sheet for details.
Field devices are wired directly to the top-mounted removable
connectors on the modules plugged into each rack. SNAP B-series
racks can accommodate up to 4, 8, 12, or 16 modules. The module
and rack design allows modules to simply “snap” on and off the
mounting rack.
SNAP racks use a retention rail locking system that holds modules
securely to the rack. Normally, a hold-down screw is not required.
However, for applications that require additional module security,
SNAP racks have provisions for two 4-40 by ½-inch standard
machine screws to hold each module in position.
MC and MC-P model racks provide an auxiliary screw-type terminal
strip for field wiring common connections such as loop power
distribution. MC racks use a fixed terminal strip, while MC-P racks
use removable connectors for easy maintenance (see enlarged view
on the following page).
© 2006–2009 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
Features
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
Secure mounting for SNAP I/O modules plus a SNAP
brain or on-the-rack SNAP controller
Analog, digital, and serial modules on the same rack
Panel or DIN-rail mounting
Modules snap into place
®
protocols, and with some Ethernet-based SNAP Ultimate
“Specifications” on page
®
and
3.
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
Part Numbers
SNAP-B4M*
SNAP-B8M*
SNAP-B12M*
SNAP-B16M*
SNAP-B8MC
SNAP-B12MC
SNAP-B16MC
SNAP-B8MC-P
SNAP-B12MC-P
SNAP-B16MC-P
SNAP-D64RS*
SNAP-FUSE7.5AB
SNAP-FUSE4AB
SNAP-FUSE1AB
SNAP-TEX-DRC10
SNAP-TEX-REC10N
SNAP-TEX-REC10W
* Factory Mutual (FM) approved
All SNAP racks offer panel mounting and the option of DIN-rail
mounting. SNAP racks require a 5 VDC power source.
SNAP-B4M, SNAP-B8M, SNAP-B12M, SNAP-B16M, and
SNAP-D64RS racks are Factory Mutual approved.
Part
4-module rack
8-module rack
12-module rack
16-module rack
8-module rack with extra terminal block for
field wiring
12-module rack with extra terminal block for
field wiring
16-module rack with extra terminal block for
field wiring
8-module rack with extra terminal block for
field wiring, pluggable
12-module rack with extra terminal block for
field wiring, pluggable
16-module rack with extra terminal block for
field wiring, pluggable
16-module rack for digital-only SNAP Ulti-
mate, SNAP Ethernet, and SNAP-PDPRS64
Profibus brains
7.5-amp fuse, 25-pack
4-amp fuse, 25-pack
1-amp fuse, 25-pack
SNAP PAC rack DIN-rail adapter clip,
10-pack
Narrow end cap for SNAP PAC racks DIN-rail
assemblies, 10-pack
Wide end cap for SNAP PAC racks DIN-rail
assemblies with terminal strips, 10-pack
SNAP B-Series Racks
Description
PAGE
1

Related parts for SNAP-RACKDIN

SNAP-RACKDIN Summary of contents

Page 1

... Panel or DIN-rail mounting Modules snap into place Description NOTE: For racks to use with SNAP PAC controllers and brains, see Opto 22 form #1684, the SNAP PAC Racks Data Sheet. NOTE: M-series racks (such as the SNAP-M64), used with SNAP Simple brains and SNAP-UP1-M64 controllers, have been replaced by SNAP PAC racks ...

Page 2

... Description (continued) SNAP-B8M (8-Module Position I/O Mounting Rack) Shown with B3000 brain (purchased separately) SNAP-B8MC (8-Module Position I/O Mounting Rack) Shown with B3000 brain (purchased separately) PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 2 © ...

Page 3

... See the processor’s data sheet for details. 2 Power requirements shown are for a rack, a processor, and a full load of 2-channel analog modules (for the SNAP-D64RS, a full load of 4-channel digital modules). Power requirements for other SNAP modules are higher. See module data sheets. ...

Page 4

... SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 4 © 2006–2009 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. SNAP B-Series Racks MC and MC-P models only: For detailed information on terminal strip usage, see ...

Page 5

... SNAP B-Series Racks Dimensional Drawings Dimensions—SNAP-D64RS Rack and B-Series Racks with Terminal Strips Overall Length Dimensions (SNAP-D64RS and B-series racks with terminal strips) Part Number SNAP-B8MC 8-module rack for other brains, SNAP-B8MC-P SNAP-B12MC 12-module rackfor other brains, SNAP-B12MC-P SNAP-B16MC 16-module rackfor other brains, ...

Page 6

... Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. Width Description (inches) 4-module rack 3.91 8-module rack 3.91 12-module rack 3.91 16-module rack 3.91 SNAP B-Series Racks Width Length Length (mm) (inches) (mm) 99.31 6.24 158.41 99.31 9.24 234 ...

Page 7

... SNAP B-Series Racks Dimensional Drawings (continued) SNAP-D64RS Rack and B-Series Racks with Terminal Strips: Right Side View with DIN-Rail Option Installed Processor Height* SNAP-UP1-ADS SNAP-B3000-ENET SNAP-ENET-RTC 4.12 in. (104.6 mm) SNAP-UP1-D64 SNAP-ENET-D64 B3000 SNAP-B4 3.70 in. (95.9 mm) SNAP-B6 SNAP-BRS * Height listed is from the processor’s mounting surface to the highest part of the proces- sor. Height does not include wiring or cables. SALES 800-321-6786 • ...

Page 8

... Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. Processor Part Number SNAP-UP1-ADS SNAP-ENET-RTC SNAP-B3000-ENET B3000 SNAP-BRS SNAP-B4 SNAP-BRS-HA SNAP-B6 SNAP-B3000-MODBUS B3000-HA SNAP B-Series Racks ...

Page 9

... SNAP B-Series Racks Mounting NOTE: If you are not using hold-down screws, the SNAP rack assembly should be mounted horizontally. Use the following steps to mount racks as shown in the diagrams on the next two pages. Preferred Method: Template (Product on site) 1. Use SNAP rack mounting extrusion as template. ...

Page 10

... Mounting (continued) SNAP-D64RS Rack and B-Series Racks with Terminal Strips: Typical Plain View of SNAP Mounting Extrusion See instructions and table on PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 10 © ...

Page 11

... SNAP B-Series Racks Mounting (continued) B-Series Racks Without Terminal Strips: Typical Plain View of SNAP Mounting Extrusion See instructions and table on page 9. SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006–2009 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...

Page 12

... Wiring Diagrams—B-Series Models with Terminal Strips Terminal Strip Usage—Digital NOTE: Consult the SNAP module data sheet for your specific module for additional wiring information. PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 12 © ...

Page 13

... Wiring Diagrams—B-Series Models with Terminal Strips Terminal Strip Usage—Digital (continued) Example: Digital DC Output (Sourcing) Using Terminal Strip NOTE: Consult the SNAP module data sheet for your specific module for additional wiring information. Example: Digital DC Output (Sinking) Using Terminal Strip SALES 800-321-6786 • ...

Page 14

... Wiring Diagrams—B-Series Models with Terminal Strips Terminal Strip Usage—Analog NOTE: Consult the SNAP module data sheet for your specific module for additional wiring information. PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 14 © ...

Page 15

... Wiring Diagrams—B-Series Models with Terminal Strips Terminal Strip Usage—Analog (continued) Example: Analog Output (4–20 mA Current: Sourcing) Using Terminal Strip NOTE: Consult the SNAP module data sheet for your specific module for additional wiring information. Example: Analog Output (4–20 mA Current: Sinking) Using Terminal Strip SALES 800-321-6786 • ...

Page 16

... Wiring Diagrams—B-Series Models with Terminal Strips Terminal Strip Usage—Analog (continued) NOTE: Consult the SNAP module data sheet for your specific module for additional wiring information. PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 16 © ...

Page 17

... TPO, and pulse generation and measurement. SNAP I/O I/O provides the local connection to sensors and equipment. Opto 22 SNAP I/O offers points of reliable I/O per module, depending on the type of module and your needs. Analog, digital, serial, and special-purpose modules are all mixed on the same mounting rack and controlled by the same processor (SNAP PAC brain or rack-mounted controller) ...

Related keywords