MAT UNITED AUTOMATION, MAT Datasheet

TRIGGER MODULE, PHASE ANGLE

MAT

Manufacturer Part Number
MAT
Description
TRIGGER MODULE, PHASE ANGLE
Manufacturer
UNITED AUTOMATION
Series
X10224r
Datasheet

Specifications of MAT

Supply Voltage
230V
Operating Temperature Range
0°C To +65°C
Approval Bodies
CE
External Depth
22mm
External Length / Height
42mm
External Width
22mm
Fixing Hole Diameter
10mm
For
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAT-13946-001-200347
Manufacturer:
YAMAICH
Quantity:
9 689
Part Number:
MAT-15-7
Manufacturer:
MITSUMI
Quantity:
15 000
Part Number:
MAT-20
Manufacturer:
MCL
Quantity:
129
Part Number:
MAT-25
Manufacturer:
MCL
Quantity:
66
Part Number:
MAT-DG0005-A001
Manufacturer:
NDK
Quantity:
1 395
Part Number:
MAT-VY0013-T001
Manufacturer:
NEC
Quantity:
20 000
Part Number:
MAT01AH
Manufacturer:
ST
0
Part Number:
MAT01G
Manufacturer:
ADI/亚德诺
Quantity:
20 000
SPECIFICATIONS
AC system line voltage
Line frequency
Minimum offset at 110V
Minimum offset at 230V
Conduction phase angle typical
Controlled phase angle typical
Isolation voltage
Maximum leakage current
Storage temperature
Operating temperature
Mounting hole diameter
FUSING
It is recommended to use semiconductor fast acting type fuses or circuit breakers
(Semiconductor-MCB) for unit/device protection. On initial switch on some loads may need
an increased Factor of Safety (F of S) for unit and/or device protection.
(See the SRA Datasheet for further information).
CE MARKING
This product family carries a CE marking . These phase angle controllers need a suitable
remote filter. For information see recommendation section and contact our sales desk. (See
Declaration of Conformity).
RECOMMENDATION
Other documents available on request, which may be appropriate for your applications.
CODE
X10229
X10213
X10255
AP02/4
NOTE It is recommended that installation and maintenance of this equipment should be done
with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by suitably
qualified/trained personnel. The regulations contain important requirements regarding safety of
electrical equipment. (For International Standards refer to I.E.C. Directive I.E.C. 950).
ORDER CODE:
State part number: MAT.
Optional extras include: Triac, Heatsink assembly.
IDENTITY
RFI
ITA
SRA
COS
1Southport Business Park
Kew
Southport, PR8 4HQ
ENGLAND
Page No. 2 of 2
UNITED AUTOMATION LIMITED
DESCRIPTION
Filtering recommendation - addressing EMC directive.
Interaction, uses for phase angle and for burst fire control.
Safety requirements - addressing the Low Voltage Directive
(LVD) including :-Thermal data/cooling ; Live parts warning
& Earth requirements; Fusing recommendations.
UAL Conditions of sale
Issue 2
Tel: 0044 (0) 1704
Tel: 0044 (0) 1704
Fax: 0044 (0) 1704
Enquiry@united-automation.com
Date 16/12/99
516500 Main
516516 Sales
516501
110/230V ± 10%
50/60Hz
0-50%
0-50%
0-160°
30 to 160°
2500V rms
6mA
-20 to 85 C
0 to 65 C
10mm
SPECIFICATIONS
AC system line voltage
Line frequency
Minimum offset at 110V
Minimum offset at 230V
Conduction phase angle typical
Controlled phase angle typical
Isolation voltage
Maximum leakage current
Storage temperature
Operating temperature
Mounting hole diameter
FUSING
It is recommended to use semiconductor fast acting type fuses or circuit breakers
(Semiconductor-MCB) for unit/device protection. On initial switch on some loads may need
an increased Factor of Safety (F of S) for unit and/or device protection.
(See the SRA Datasheet for further information).
CE MARKING
This product family carries a CE marking . These phase angle controllers need a suitable
remote filter. For information see recommendation section and contact our sales desk. (See
Declaration of Conformity).
RECOMMENDATION
Other documents available on request, which may be appropriate for your applications.
CODE
X10229
X10213
X10255
AP02/4
NOTE It is recommended that installation and maintenance of this equipment should be done
with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by suitably
qualified/trained personnel. The regulations contain important requirements regarding safety of
electrical equipment. (For International Standards refer to I.E.C. Directive I.E.C. 950).
ORDER CODE:
State part number: MAT.
Optional extras include Triac, Heatsink assembly.
IDENTITY
RFI
ITA
SRA
COS
1Southport Business Park
Kew
Southport, PR8 4HQ
ENGLAND
Page No. 2 of 2
UNITED AUTOMATION LIMITED
DESCRIPTION
Filtering recommendation - addressing EMC directive.
Interaction, uses for phase angle and for burst fire control.
Safety requirements - addressing the Low Voltage Directive
(LVD) including :-Thermal data/cooling ; Live parts warning
& Earth requirements; Fusing recommendations.
UAL Conditions of sale
Issue 2
Tel: 0044 (0) 1704
Tel: 0044 (0) 1704
Fax: 0044 (0) 1704
Enquiry@united-automation.com
Date 16/12/99
516500 Main
516516 Sales
516501
110/230V ± 10%
50/60Hz
0-50%
0-50%
0-160°
30 to 160°
2500V rms
6mA
-20 to 85 C
0 to 65 C
10mm

Related parts for MAT

MAT Summary of contents

Page 1

... SRA Datasheet for further information). CE MARKING This product family carries a CE marking . These phase angle controllers need a suitable remote filter. For information see recommendation section and contact our sales desk. (See Declaration of Conformity). RECOMMENDATION Other documents available on request, which may be appropriate for your applications. ...

Page 2

... MAT X10224 INTRODUCTION The MAT is a variable phase angle triac trigger module compact, safe and tamperproof unit capable of driving all typical triacs on 230/110V ac regulator circuits. The unit has an inclusive manual control potentiometer and minimum output trimmer built in a industrial panel mounting enclosure. ...

Page 3

This document was created with Win2PDF available at The unregistered version of Win2PDF is for evaluation or non-commercial use only. http://www.daneprairie.com. ...

Related keywords