01230.9-00 STEGO, 01230.9-00 Datasheet - Page 38

Humidity And Temperature Control

01230.9-00

Manufacturer Part Number
01230.9-00
Description
Humidity And Temperature Control
Manufacturer
STEGO
Datasheet

Specifications of 01230.9-00

Mounting Type
DIN Rail
Operating Voltage Max
120V
Operating Temperature Max
140°F
Output Type
Temperature
Supply Voltage
120VAC
Temperature Accuracy ±
1K
Humidity Range
50 To 90% RH
Operating Temperature Min
32°F
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1)
RFF 018 Roof Filter Fan
REF 118 Roof Exit Filter
FM 086 Filter Mats
air volume increases by 15% when operating 230VAC filter fans at 60Hz
01850.0-00
01851.0-00
Part No.
11850.0-00
Part No.
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application.
230VAC, 50Hz
120VAC, 60Hz
Operating
4x Axial fans
voltage
STEGO, Inc. · 1395 South Marietta Parkway · Building 800 · Marietta, GA 30067 · Tel: (770) 984-0858 · Fax: (770) 984-0615
Mounting depth
Roof Filter Fan
none
1)
G3 (1 packing unit = 3 pcs.)
Air volume, free blowing
(w/ G3 filter mat)
206 cfm (350m³/h)
237 cfm (402m³/h)
Filter mat
Enclosure cut-out
Toll free: 1-888-783-4611 (US & Canada only) · www.stegousa.com
(44 mm)
1.7”
9.8 x 9.8”
Roof Exhaust
2.4” (62 mm)
Filter
(62 mm)
2.4”
Air volume, free blowing
(w/out filter mat)
294 cfm (500m³/h)
338 cfm (575m³/h)
Roof filter fans and roof exhaust filters are used in enclosures from which warm air must be
diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan
is used to expel warm air from within the enclosure. Alternatively, the roof exhaust filter pro-
vides passive ventilation. The RFF 018 series utilizes four small axial fans instead of one
large one, improving reliability and maintaining continuous operations even if one of the fans
should fail.
| |
Weight (approx.)
4.4 lbs. (2.0kg)
Very low noise
Minimal mounting depth
High air volume
Uniform air circulation
High reliability
Time-saving installation
Technical Data
Axial fans, ball bearing
Connection
Housing
Filter mat
Filter material
Operating / Storage temperature
Protection class
Protection type
Approvals
Important note: For reasons of pressure compensation, the roof filter fan must always be operated in combi-
nation with another filter fan (e.g. Part No. 01803.0-00) or a passive intake filter (e.g. Part No. 11803.0-00).
consumption
Hole centers
Power
60W
60W
G3 acc. to DIN EN 779, filtering degree 85%
RFF 018 Roof Filter Fan 237 cfm
Average noise level
(DIN EN ISO 4871)
55db (A)
55db (A)
Filter mat
service life min. 50,000h at 77°F (25°C) and 65% RH
aluminum fan body, plastic rotor
3-pole clamp, AWG 14 (2.5mm²), clamping torque 0.8Nm max.
plastic, UL 94V-0 / lacquered steel sheet, light grey
G3 acc. to DIN EN 779, filtering degree 85%
synthetic fiber with progressive construction, temperature
resistant to 100°C, self-extinguishing class F1;
moisture resistant to 100% RH, reusable - can be cleaned by
washing or vacuuming
49 to +158°F (-45 to +70°C)
I (grounded)
IP43 (with G3 filter mat) / IP33 (without filter mat)
UL File No. E234324
9.8” (250 mm)
10” (256 mm)
11.1 x 11.1” (282 x 282 mm)
Part No. 08613.0-00
Ø 0.12”
(3 mm)
1.7” (44mm)
1.7” (44mm)
Mounting
depth
Enclosure cut-out
Enclosure
9.8 x 9.8”
9.8 x 9.8”
cut-out
IP43 (w/ G3 filter mat)
Protection type
9.7 lbs. (4.40kg)
9.7 lbs. (4.40kg)
(approx.)
Weight

Related parts for 01230.9-00