SM1551152K CARLO GAVAZZI, SM1551152K Datasheet - Page 2

Signal Conditioning, Isolation Amplifiers

SM1551152K

Manufacturer Part Number
SM1551152K
Description
Signal Conditioning, Isolation Amplifiers
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of SM1551152K

Operating Temperature Range
-20°C To +50°C
Accuracy %
3%
External Height
80mm
External Width
35mm
External Depth
83mm
Rpm Measuring Range
200RPM To 2000RPM
SM 155
Supply Specifications
Power supply
Rated operational power
Mode of Operation/Level Setting
The relay is controlled by
mechanical triggering, e.g.
microswitch, reed relay, limit
switch etc. (examples 1 and
2), or by electronic trigger-
ing, e.g. inductive or capaci-
tive sensors (NAMUR/DIN
19234) (examples 3 and 4).
Examples 1 and 3
The relay operates when the
number of R.P.M. exceeds
the set value.
Wiring Diagrams
Ex. 1, 2 - Mechanic triggering with metallic contact
2
Rated operational voltage
Through terminals 2, 10
Dielectric voltage
Transient protection
DC models
AC models
024:
115:
230:
724:
The relay releases when the
number of R.P.M. is less than
the set value. See hysteresis.
Example 2 and 4
By interconnecting pins 8
and 11 the relay function is
inverted, i.e. the relay releas-
es when the number of
R.P.M. exceeds the set
value.
The relay operates when the
number of R.P.M. is less than
Overvoltage cat. III
(IEC 60664, IEC 60038)
24 VAC ± 15%, 45 to 65 Hz
115 VAC ± 15%, 45 to 65 Hz
230 VAC ± 15%, 45 to 65 Hz
24 VDC ± 15%
2 kV
> 3kV
4 VA
2 W
the set value. See hysteresis.
Instrument connection
A moving-coil instrument
with a scale calibrated in
R.P.M. can be connected to
the SM 155. The instrument
has 1 mA full scale deflec-
tion.
The relay generates max. 8.2
V on the instrument termi-
nals (pins 8 and 9) across an
internal resistance of 8.2 k
in the relay. The ideal internal
General Specifications
Reaction time
Accuracy of measurement
Indication for
Environment
Housing dimensions
Weight
Approvals
CE Marking
Ex. 3, 4 - Electr. trig. with NAMUR/DIN 19234 sensor
Power supply ON
Output relay ON
Degree of protection
Operating temperature
Storage temperature
AC power supply
DC power supply
Specifications are subject to change without notice (13.03.01)
resistance of the instrument
is 110
internal resistance of ± 100
Level Setting
Knob adjustable on relative
scale
LED, red
IP 20
Time between 2 pulses at
the set value of the poten-
tiometer
± 3%
LED, green
-20 to +50°C
-50 to +85°C
35 x 80 x 83 mm
Approx. 200 g
Approx. 125 g
UL, CSA
Yes
results in an error of ± 1%.
. A deviation in the

Related parts for SM1551152K