230572 MAXON MOTORS, 230572 Datasheet - Page 15

no-image

230572

Manufacturer Part Number
230572
Description
AMPLIFIER, DC MOTORS DEC, 50/5
Manufacturer
MAXON MOTORS
Datasheet

Specifications of 230572

Supply Voltage Range
10VDC To 50VDC
Armature Current Max
5A
Svhc
No SVHC (15-Dec-2010)
External Depth
24mm
External Length / Height
95mm
External Width
75mm
For Use With
EC Motors With Hall
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1-Q-EC Amplifier DEC 50/5
9
9.1 No LED
9.2 Green LED
9.3 Red LED flickers or flashes intermittently
9.4 Red LED flashes regularly
14
maxon motor control
Operating Status Display
Red and green LEDs show the operating status.
Reason:
The controller recognises invalid conditions in the Hall sensor inputs.
Reason:
The following error messages can be distinguished depending on flashing type:
Definition
Flashing type (green LED)
Flashing type (red LED)
• No supply voltage
• Fuse blown
• Wrong polarity of supply voltage
• Hall sensors supply voltage V
• Hall sensors not connected or incorrectly connected
• Intermittent Hall sensor supply lines
• Excessive interference to Hall sensor supply lines
• Faulty Hall sensors in motor
(Solution: change supply line feeds, use shielded cable)
maxon motor
October 2008 Edition / Doc.No. 544910-06 / subject to change
LED on
LED on
LED off
CC
Hall is short-circuited
Operating status
Amplifier active
/Disable function active
/Brake function active
Error message
Thermal overload protection is active
When switched on, the controller
recognises invalid conditions in the
Hall sensor inputs => check Hall
sensor wiring and Hall sensor signals
An invalid operating mode was set on
switches S3-S6
• Motor shaft is blocked
• Load too great
• I
• No winding connection
max
setting too low