14/01/2010
88970119-GSM
General environment characteristics for CB, CD, XD, XB, XR and XE product types
Characteristics of the communication Modem system
General characteristics
Supply
Certifications
Conformity with the low voltage directive
Conformity with the EMC directive
Earthing
Protection rating
Overvoltage category
Pollution
Maximum utilisation altitude
Mechanical resistance
Resistance to electrostatic discharge
Resistance to HF interference
Conducted and radiated emissions
Operating temperature
Storage temperature
Relative humidity
Mounting
Screw terminals connection capacity
Certifications
Nominal voltage (V)
Operating limits
Ripple
Nominal current under 12 V DC
- STN modem for wired transmission networks
- GSM modem for wireless communication
For remote control of your application
Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
Millenium 3 program can be downloaded, modified and sent
Input and output states, as well as all program values, can be polled and controlled remotely
2 types of pre-configured ready-to-use modem:
UL, CSA
GL: except for 88 970 32x (pending)
In accordance with 73/23/EEC:
EN (IEC) 61131-2 (Open equipment)
In accordance with 89/336/EEC:
EN (IEC) 61131-2 (Zone B)
EN (IEC) 61000-6-2,
EN (IEC) 61000-6-3 (*)
EN (IEC) 61000-6-4
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B: using in metallic
cabinet)
None
In accordance with IEC/EN 60529:
IP40 on front panel
IP20 on terminal block
3 in accordance with IEC/EN 60664-1
Degree: 2 in accordance with IEC/EN 61131-2
Operation: 2000 m
Transport: 3,048 m
Immunity to vibrations IEC/EN 60068-2-6, Fc test
Immunity to shock IEC/EN 60068-2-27, Fa test
Immunity to ESD IEC/EN 61000-4-2, level 3
Immunity to radiated electrostatic fields
IEC/EN 61000-4-3,
Immunity to fast transients (burst immunity)
IEC/EN 61000-4-4, level 3
Immunity to shock waves
IEC/EN 61000-4-5
Radio frequency in common mode
IEC/EN 61000-4-6, level 3
Voltage dips and breaks (AC)
IEC/EN 61000-4-11
Immunity to damped oscillatory waves
IEC/EN 61000-4-12
Class B (*) in accordance with EN 55022/11 group 1
(*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in metallic cabinet)
-20 →+55°C (+40°C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
-40 →+70°C in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2
95% max. (no condensation or dripping water) in accordance with IEC/EN 60068-2-30
On symmetrical DIN profile, 35 x 7.5 mm and 35 mm x 15 or panel (2 x 4 mm Ø)
Flexible wire with ferrule =
1 conductor: 0.25 to 2.5 mm² (AWG 24...AWG 14)
2 conductors 0.25 to 0.75 mm² (AWG 24...AWG 18)
Semi-rigid wire =
1 conductor: 0.2 to 2.5 mm² (AWG 25...AWG 14)
Rigid wire =
1 conductor: 0.2 to 2.5 mm² (AWG 25...AWG 14)
2 conductors 0.2 to 1.5 mm² (AWG 25...AWG 16)
Tightening torque =
0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm)
See page 22, except:
UL, CSA
12 →24 V DC
-13% / + 20%
or 10 →28,8 V DC
5% max.
30 mA
www.crouzet.com