DF51-322-1K1 MOELLER, DF51-322-1K1 Datasheet

VARIABLE SPEED DRIVE UNIT, 51SERIES

DF51-322-1K1

Manufacturer Part Number
DF51-322-1K1
Description
VARIABLE SPEED DRIVE UNIT, 51SERIES
Manufacturer
MOELLER
Datasheet

Specifications of DF51-322-1K1

Supply Voltage Range
180VAC To 264VAC
No. Of Phases
Single, Three
Power Rating
1.1kW
Output Voltage Max
264VAC
Frequency Range
47Hz To 63Hz
Svhc
No SVHC (18-Jun-2010)
Approval
RoHS Compliant
Type: DF51−322−1K1
Article No.: 289106
Sales text """Frequency inverter DF51(1,1 kW; 230V)
Notes concerning the table header
All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and
an ambient temperature of +40 °C, for operation of a four−pole three−phase asynchronous motor.
1
Ordering information
Rated voltage
Max. rated operational current
Rated power for motors
Rating range
Description
General
Standards
Ambient temperature
Operating temperature
at 230 V 3−phase AC
U
I
P
e
e
°C
kW
V
A
1 AC 180...264 V ± 0 %
3 AC 180...264 V ± 0 %
5
1.1
0.25 – 2.2 kW at 230 V
Single and three−phase
connection
EN 50178, IEC 61800−3
−10 to +40 with rated current I
at a clock frequency of 5 kHz;
up to +50 °C at a reduced
clock frequency of 2 kHz and
reduced output current of 80 %
I
e
e

Related parts for DF51-322-1K1

DF51-322-1K1 Summary of contents

Page 1

... Type: DF51−322−1K1 Article No.: 289106 Sales text """Frequency inverter DF51(1,1 kW; 230V) Ordering information Rated voltage Max. rated operational current Rated power for motors at 230 V 3−phase AC Rating range Description Notes concerning the table header All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40 ° ...

Page 2

Max. duty factor (c.d.f.) with lowest impedance R B Shock resistance Pollution degree Climatic proofing Altitude Mounting position Free surrounding areas Emitted interference Interference immunity Insulation resistance Discharge current to PE Protection type Protection against direct contact Protective isolation against ...

Page 3

U = 3−phase 230 Alternative DC supply Modulation method Switching frequency Output voltage Output frequency Frequency resolution Frequency resolution Frequency error limit ± Max. rated operational current Permissible overcurrent Torque during start ...

Page 4

Analog Outputs Digital analog (parameters can be defined) Terminal capacities Cable lengths Relay connection Control circuit Notes Dimensions Notes If the frequency inverter installed in an enclosure, control panel or similar housing, ...

Page 5

... Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. HPL−C2007G V2.1 5 ...