4-1394462-9 Tyco Electronics, 4-1394462-9 Datasheet

CONN FEMALE MINUS COUPLER 12AWG

4-1394462-9

Manufacturer Part Number
4-1394462-9
Description
CONN FEMALE MINUS COUPLER 12AWG
Manufacturer
Tyco Electronics
Series
Solarlok®r
Type
Female Couplerr
Datasheets

Specifications of 4-1394462-9

Coded, Keyed
Minus
Features
12 AWG
Contact Termination
Crimp
No. Of Contacts
1
Connector Mounting
Cable
Gender
Receptacle
Contact Material
Copper Alloy
Contact Plating
Silver
Connector Type
Plug & Socket
Product
Cable Couplers
Mounting Style
Wire
Termination Style
Quick Connect
Description/function
Minus Female, Keyed
Wire Size (awg)
12
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A98828
SOLARLOK
Interconnection System
RoHS
Ready

Related parts for 4-1394462-9

4-1394462-9 Summary of contents

Page 1

SOLARLOK Interconnection System RoHS Ready ...

Page 2

... SOLARLOK Interconnection System Table of Contents The SOLARLOK Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Large Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Large Junction Box – Parallel Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Small Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mini Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 T-Branch Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DC/AC Converter Receptacle ...

Page 3

... Different cable diameters of the world’s energy mix. ■ Operating Temperature from –40 ° +120 °C ■ Voltage Rating up to 2600 V DC ■ IEC 60228 Class 5 (stranded tin plated copper and flexible) ■ TÜV certified acc. to 2Pfg 1169/08.2007 ■ ...

Page 4

... SOLARLOK Interconnection System Large Junction Box – Serial Interconnection Part Configuration Number 1-1394723-6 2-1394723-6 0-1394723-4 0-1394723-3 2 All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector Quantity Plus Keyed Minus Keyed Catalog 889753-3 Revised 6-2008 W: 150 mm ...

Page 5

... SOLARLOK Interconnection System Large Junction Box – Parallel Interconnection Part Package Configuration Number Quantity 1394723-5 1394723-6 1394723-9 All specifications subject to change. Consult Tyco Electronics for latest specifications. Interconnection Options Plug Connector Plus Keyed Minus Keyed Catalog 889753-3 Revised 6-2008 W: 150 Contact ...

Page 6

... Junction Box Assembly with two 100 cm long 4.0 mm ✱✱ ) Junction Box Assembly with one 200 cm long 4 All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector ...

Page 7

... Junction Box Assembly with two 100 cm long 4.0 mm ✱✱ ) Junction Box Assembly with one 200 cm long 4.0 mm All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector Quantity ...

Page 8

... Junction Box Assembly with two 70 cm long 4.0 mm ✱✱ ) Junction Box Assembly with two 85 cm long 4 All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package ...

Page 9

... Junction Box Assembly with one 140 cm long 4.0 mm ✱✱ ) Junction Box Assembly with one 170 cm long 4.0 mm All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector ...

Page 10

... SOLARLOK Interconnection System Mini Junction Box – Serial Interconnection Part Configuration Number 1740863-1 1740863-2 ✱ ) Junction Box Assembly with two 85 cm long 4 All specifications subject to change. Consult Tyco Electronics for latest specifications Package Contact Rail Quantity Shape ✱ 80 Straight ✱ 80 Right-Angle 2 black solar cable and plug connector ...

Page 11

... Plus Keyed 0-1394462-2 0-1394461-1 0-1394462-4 0-1394461-3 5-1394462-6 6-1394461-5 Wire Size Male Cable Coupler 2 (mm ) 2.5 6-1394461-1 4.0 6-1394461-2 6.0 6-1394461-4 Cable Coupler with Connector Latch Locking Clip Connector Latch Locking Clip 0-1534226-1 Catalog 889753-3 Revised 6-2008 Package Quantity Minus Keyed 0-1394461-2 ...

Page 12

... All specifications subject to change. Consult Tyco Electronics for latest specifications. T-Branch Connector Plus Keyed Minus Keyed o o T-Branch Connector Plus Keyed Minus Keyed o o Catalog 889753-3 Revised 6-2008 Package Part Number Quantity 1534611-1 20 1534611-2 20 Package Part Number Quantity 1740277-1 20 1740277-2 20 ...

Page 13

... SOLARLOK Interconnection System DC/AC Converter Receptacle O-Ring and Metal Nut Wire Size Keying 2 2 2.5 mm 4.0 mm Plus (AWG 14) (AWG 12 All specifications subject to change. Consult Tyco Electronics for latest specifications. Flat Seal and Plastic Nut Package Part Number Quantity Minus 1394738-1 o 1394738-2 ...

Page 14

... Product Facts ■ Current Rating ■ Voltage Rating: 400 V ■ Protection Degree: IP67 (mated) ■ No. of Positions: 5 Poles ■ Temperature Range: –40 ° +50 °C ■ Wire Size Range: 2 2.5–6.0 mm ■ Approvals: • VDE certified • UL pending Configuration 5 Pole Receptacle o Receptacle o ...

Page 15

... 2600 Short Circuit: +250 °C Test Voltage for 5 Minutes: Min. Operating Temperature 6000 V Free Installation: –25 °C Max. Current Carrying Capacity Fixed Installation: –40 °C (Free in Air): Wire Size Range 116 A (size dependent) 2 2.5 mm (AWG 14), 2 4.0 mm (AWG 12 ...

Page 16

... Red 1-956297-5 0-956297-6 Blue 1-956297-6 0-956298-4 Black 1-956298-4 0-956298-5 0.22 Red 1-956298-5 0-956298-6 Blue 1-956298-6 0-956299-4 Black 1-956299-4 0-956299-5 0.24 Red 1-956299-5 0-956299-6 Blue 1-956299-6 Color Part Number (Inch) -1986166-2 0.17 Black -1986166-3 -1986165-2 0.19 Black -1986165-3 -1986164-2 ...

Page 17

... Proven quality ■ One- / two-pole switch ■ Main switch function ■ Lockable ■ Current ■ Voltage up to 900 V U All specifications subject to change. Consult Tyco Electronics for latest specifications. Collecting ■ strings input ■ Cable cross section ■ SOLARLOK connectors ■ ...

Page 18

... Male Cable Coupler (+) 1 1394461-3 Male Cable Coupler (–) 2 1394461-4 Female Cable Coupler (+) 3 1394462-3 2 Configuration Example at 4 Cable Assembly Wire Size: 2 4.0 mm Color: Black More variants (cable length, wire diameter, color) upon request. 16 All specifications subject to change. Consult Tyco Electronics for latest specifications. ...

Page 19

... Female Cable Coupler (+) 3 1394462-3 Female Cable Coupler (–) 4 1394462-4 Female Cable Coupler (–) 5 1394462-4 2 Configuration Example at 4 Cable Assembly Wire Size: 2 4.0 mm Color: Black More variants (cable length, wire diameter, color) upon request. All specifications subject to change. Consult Tyco Electronics for latest specifications. ...

Page 20

... Tyco Electronics SolKlip provides an extremely simpli- fied solution for terminating a continuous-run ground wire. 18 All specifications subject to change. Consult Tyco Electronics for latest specifications. Termination times are meas- With a tensile strength of up ured in seconds using the to 36 kg, the UV-resistant pre-mounted Tyco Electronics ...

Page 21

... Click Click Click Standards and Specifications SolKlip Grounding Clip: UL 467 pending, a requirement for UL 1703 solar panel listing. UL 486A-B pending, also a requirement as part of the UL 1703 approval listing. Materials Housing: Durable PPT Contact: High conductivity copper alloy Catalog 889753-3 Revised 6-2008 • ...

Page 22

... SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Cable Glands 1394462-4 1394461-4 1394462-4 1394738-4 20 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2 (4.0 mm Wiring) DC/AC Converter Catalog 889753-3 Revised 6-2008 6-1394461-2 1394462-3 1394462-3 1394738-3 ...

Page 23

... SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Plug Connectors 1394462-4 1394462-3 1394462-4 1394738-4 All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) 2 (4.0 mm Wiring) 1394462-4 DC/AC Converter Catalog 889753-3 Revised 6-2008 1394462-3 1394462-3 1394738-3 21 ...

Page 24

... Vario Crimp Head 2 7-1579001-8 (1 7-1579001-9 (4 Hand Crimping Tool incl. Vario Crimp Head and Locator Part No. 1579004-8 2 (for 1.5 + 2.5 + 4 Die Set Part No. 6-1579001-6 2 (for 1.5 + 2.5 + 4 Extraction Tool suitable for all wire sizes Part No. 1102855-3 Insulation Stripper ...

Page 25

... Wire Spring Clamp Tool Part No. 1579007-2 Dioden / Jumper Spring Clamp Tool Part No. 1579007-5 Foil Spring Clamp Tool Part No. 1579007-3 Large Box Part No. 1740969-1 Medium Box Part No. 1740969-2 Small Box Kit includes the following parts: ■ 100 Cable Coupler (Housings, Plus and Minus coded) ■ ...

Page 26

... The grommet has to be matched with the outer diameter of the solar cable (see customer drawing, Part No. 1394461 and Part No. 1394462) and the pinch ring (Part No. 1418677-2) must be applied. 24 All specifications subject to change. Consult Tyco Electronics for latest specifications. General Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Termination of the Cable Wires / Crimping of the Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Handling of the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Application Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 ...

Page 27

... SOLARLOK Interconnection System Assembly and Installation Guidelines When assembling the connectors, the following sequence must be followed: 1 Stripping the Wire (please refer to application specification # 114-74013) 8 Insert the stripped wire into the wire crimp barrel until it stops. While holding the wire in place, squeeze tool handles together until ratchet releases. ...

Page 28

... Connectors labeled with a plus or minus are keyed and can only be mated to similarly marked and keyed connectors. The polarity of the “neutral” connector must labeled with Part No. 1394725-1 or Part No. 1394725-2 nearby the connector. ■ The connector system is fully latched only when the latches are flush with the mating connector. ...

Page 29

... DC/AC Converter Receptacle (single wire seals are not available with every version). 2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013) 3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing 4 Push seal into the housing 5 Assembly of the cover cap (not available with every version) and mounting in front panel ■ ...

Page 30

... SOLARLOK Interconnection System Assembly and Installation Guidelines 4. Application Examples Fig. 14: Serial (Wire Diagram) 5. Storage See Product Specification 108-18701 ■ 6. Tooling The following tools are available for the contact crimping (please specify wire gauge required): ● ● ■ An extraction tool (Part No. 1102855-3) is needed to disassemble the connector components. ...

Page 31

... II Depending on junction box type –40 °C to +105 ° AWG 12 IP 65, closed Diameter 18 mm, (diameter 0.71 inch) –40 °C to +105 °C AWG 14, AWG 12, AWG 10 stranded wire IP 67, mated silver plated, 50, silver plated 30 – 40 Newton Coded housing ensures mating safety Contact voltage-proof Connector with crimp technology ...

Page 32

... All specifications subject to change. Consult Tyco Electronics for latest specifications. Page Part Number 26 1740210-7 24 1740210-8 2 1740210-9 2 1-1740210-0 3 1740220-1 3 1740220-2 3 1740220-3 2 1740220-4 2 1740277-1 26 1740277-2 26 1740425-1 11 1740425-3 11 1740479-1 11, 20, 21 1740483-1 11, 20, 21 1740483-2 11, 27 1740493-1 24 1740493-2 7 1740657-7 7 1740657-8 7 1740657-9 7 1-1740657-0 7 1740658-1 7 1740658-3 9 1740658-4 10 1740658-5 10 1740699-1 23 1740699-6 22 1740700-1 22 1740700-3 22 1740863-1 22 ...

Page 33

... RoHS needs. A RoHS FAQ (Frequently Asked Questions) is available with links to more detailed information. You can also submit RoHS questions and receive a response within 24 hours during a normal work week. The Support Center also provides: ■ Cross-Reference from Non-compliant to Compliant Products ■ ...

Page 34

... SOLARLOK Interconnection System Engineering Notes 32 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 6-2008 ...

Page 35

... Phone: +84-8-930-5546 Fax: +84-8-930-3443 South Africa – Port Elizabeth Phone: +27-41-503-4500 Fax: +27-41-581-0440 Spain – Barcelona Phone: +34-93-291-0330 Fax: +34-93-201-7879 Sweden – Upplands Väsby Phone: +46-8-50-72-50-00 Fax: +46-8-50-72-50-01 Switzerland – Steinach Phone: +41-71-447-0447 Fax: +41-71-447-0444 Turkey – Istanbul Phone: +90-212-281-8181-83 +90-212-282-5130/5430 ...

Page 36

... Tyco Electronics AMP GmbH Siemensstr. 13 67346 Speyer / Germany Phone: +49-(0)6232-30-2520 Fax: +49-(0)6232-30-2243 www.tycoelectronics.com AMP, SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. © 2008 Tyco Electronics Ltd. 889753-3 Revised 6-2008 5M ST ...