A0214Y APEM Components, A0214Y Datasheet - Page 9

no-image

A0214Y

Manufacturer Part Number
A0214Y
Description
30mm Ind Ctrl Pb Operator Flush Mount Metal Bezel Illum Mom
Manufacturer
APEM Components
Series
A02r
Datasheet

Specifications of A0214Y

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G
G-24
PANEL MOUNTING ASSEMBLY
• Drill/punch hole in panel as shaped above.
• Assemble front operator through hole and :
b/ Rectangular types : tighten two panel fixing screws in
• Wire chosen switch block as required and snap onto
front operator.
• Snap end cap onto switch block.
• Fit bulb if required using tool No 30-0002.
• Snap screen onto reflector assembly with legend in
between if required ans snap into front operator TAKING
CARE TO LINE UP THE LOCATING SLOT WITH THE
POLARISING DOT, and not to damage the seal.
a/ Round & square types : tighten nut to a maximum
EMERGENCY
STOP
torque of 0,8Nm using tool No 30-0001. Snap on
adaptor block
front to a maximum torque of 6cNm.
A02 series
Industrial controls
Installation
LEVERS SWITCHES
ROTARY
SWITCHES
KEYLOCK
Modular construction / panel mounting
www.apem.com
PUSHBUTTONS & INDICATORS
PANEL CLAMP
FIXING SCREW
TO REMOVE BULB
Remove reflector/screen assembly. Use the bulb extractor
30-0002 to remove the bulb.
TO REMOVE SWITCH BLOCK
Lever out latches using small screwdriver taking care not to
overbend, and pull off the block from the front operator.
A02 Accessories
End cap terminal guard offering unique terminal protection.
6.35 mm push on tab terminals.
Specify “SP” to the end of the switchblock and operator P/N.
Example : A02503SP.
SCREEN
LEGEND
REFLECTOR
LOCATING
SLOT
BULB
POLARISING
DOT
FIXING
NUT
OPERATOR
ADAPTOR BLOCK
SWITCH BLOCK
END CAP
PANEL
SEAL
Round & square operators
Rectangular operators
Max. panel thickness : 8 mm (.315)
(.866 DIA
Ø22.00
Part No : 14-0005
PANEL CUT
0.00/+0.50
.000/+.019
)
-
29.50
OUT
(1.161
(.511)
13.00
0.00/+0.50
.000/+.019
APEM
)