LSN-1.5/10-D3-C Murata Power Solutions Inc, LSN-1.5/10-D3-C Datasheet - Page 4

DC/DC Converter

LSN-1.5/10-D3-C

Manufacturer Part Number
LSN-1.5/10-D3-C
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of LSN-1.5/10-D3-C

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
3V To 3.6V
Power Rating
15W
Output Voltage
1.5V
Output Current
10A
Approval Bodies
EN, IEC, UL
Supply Voltage
3V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
elements and should be selected for bulk capacitance, low ESR, and appro-
priate frequency response. Any scope measurements of PARD should be
made directly at the DC/DC output pins with scope probe ground less than
0.5" in length.
All external capacitors should have appropriate voltage ratings and be located
as close to the converters as possible. Temperature variations for all relevant
parameters should be taken into consideration.
The most effective combination of external I/O capacitors will be a function of
your line voltage and source impedance, as well as your particular load and
layout conditions.
Input Fusing
Most applications and or safety agencies require the installation of fuses at
the inputs of power conversion components. LSN D3 Series DC/DC convert-
ers are not internally fused. Therefore, if input fusing is mandatory, either a
normal-blow or a fast-blow fuse with a value no greater than 17 Amps should
be installed within the ungrounded input path to the converter.
As a rule of thumb however, we recommend to use a fast-blow fuse with a
typical value of about twice the maximum input current, calculated at low line
with the converters minimum effi ciency.
Safety Considerations
LSN D3 SIP's are non-isolated DC/DC converters. In general, all DC/DC's
must be installed, including considerations for I/O voltages and spacing/sepa-
ration requirements, in compliance with relevant safety-agency speci-
fi cations (usually UL/IEC/EN60950).
In particular, for a non-isolated converter's output voltage to meet SELV
(safety extra low voltage) requirements, its input must be SELV compliant.
If the output needs to be ELV (extra low voltage), the input must be ELV.
Input Overvoltage and Reverse-Polarity Protection
LSN D3 SIP Series DC/DC's do not incorporate either input overvoltage or
input reverse-polarity protection. Input voltages in excess of the specifi ed
absolute maximum ratings and input polarity reversals of longer than "instan-
taneous" duration can cause permanent damage to these devices.
Start-Up Time
The V
ramping input voltage crosses the lower limit of the specifi ed input voltage
range (3 Volts) and the fully loaded output voltage enters and remains within
its specifi ed accuracy band. Actual measured times will vary with input source
impedance, external input capacitance, and the slew rate and fi nal value of
the input voltage as it appears to the converter.
The On/Off to V
the On/Off Control with the nominal input voltage already applied to the
converter. The specifi cation defi nes the interval between the time at which the
converter is turned on and the fully loaded output voltage enters and remains
within its specifi ed accuracy band. See Typical Performance Curves.
Remote Sense
LSN D3 SIP Series DC/DC converters offer an output sense function on pin 3.
The sense function enables point-of-use regulation for overcoming moderate
IN
to V
OUT
OUT
Start-Up Time is the interval between the time at which a
Start-Up Time assumes the converter is turned off via
Single Output, Non-Isolated, 3.3V
www.murata-ps.com
The on/off control function, however, can be externally inverted so that the
converter will be disabled while the input voltage is ramping up and then
"released" once the input has stabilized.
IR drops in conductors and/or cabling. Since these are non-isolated devices
whose inputs and outputs usually share the same ground plane, sense is
provided only for the +Output.
The remote sense line is part of the feedback control loop regulating the DC/
DC converter’s output. The sense line carries very little current and conse-
quently requires a minimal cross-sectional-area conductor. As such, it is not
a low-impedance point and must be treated with care in layout and cabling.
Sense lines should be run adjacent to signals (preferably ground), and in
cable and/or discrete-wiring applications, twisted-pair or similar techniques
should be used. To prevent high frequency voltage differences between V
and Sense, we recommend installation of a 1000pF capacitor close to the
converter.
The sense function is capable of compensating for voltage drops between
the +Output and +Sense pins that do not exceed 10% of V
Power derating (output current limiting) is based upon maximum output
current and voltage at the converter's output pins. Use of trim and sense
functions can cause the output voltage to increase, thereby increasing output
power beyond the LSN's specifi ed rating. Therefore:
The internal 10.5: resistor between +Sense and +Output (see Figure 1)
serves to protect the sense function by limiting the output current fl owing
through the sense line if the main output is disconnected. It also prevents
output voltage runaway if the sense connection is disconnected.
On/Off Control and Power-up Sequencing
The On/Off Control pin may be used for remote on/off operation. LSN D3 SIP
Series DC/DC's are designed so they are enabled when the control pin is
left open (internal pull-down to Common) and disabled when the control pin
is pulled high (+2.8V to +V
Dynamic control of the on/off function is best accomplished with a mechani-
cal relay or open-collector/open-drain drive circuit. The drive circuit should
be able to sink appropriate current when activated and withstand appropriate
voltage when deactivated.
Figure 2. Driving the On/Off Control Pin with an Open-Collector Drive Circuit
Note: Connect the +Sense pin (pin 3) to +Output (pin 4) at the DC/DC
converter pins, if the sense function is not used for remote regulation.
[V
(V
OUT
OUT
(+) – Common] – [Sense(+) – Common] d 10%V
at pins) x (I
ON/OFF
CONTROL
IN
OUT
, 1-2.5V
IN
LSN-10A D3 Models
) d rated output power
), as shown in Figure 2 and 2a.
16 Dec 2009 MDC_LSN10A-D3.B03 Page 4 of 14
COMMON
+INPUT
1.1kΩ
0.75kΩ
OUT,
10A, DC/DC's in SIP Packages
5kΩ
email: sales@murata-ps.com
OUT
.
OUT
OUT

Related parts for LSN-1.5/10-D3-C