WPC03R12S05LC Murata Power Solutions Inc, WPC03R12S05LC Datasheet - Page 2

DC/DC Converter

WPC03R12S05LC

Manufacturer Part Number
WPC03R12S05LC
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Series
WPC03Rr
Datasheet

Specifications of WPC03R12S05LC

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
9V To 18V
Power Rating
3W
Output Voltage
5V
Output Current
600mA
Approval Bodies
EN, UL
Supply Voltage
12V
Dc / Dc Converter Case Style
DIP
Product
Isolated
Output Power
3 W
Input Voltage Range
9 V to 18 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions WPC03 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500V pk for 10 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WPC03 series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specifi ed test voltage.
www.murata-ps.com
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC
for 10 seconds. The pin termination fi nish on this product series is matte tin (100 microns min.) over
nickel (40-80 microinches). The series is backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
3W Regulated Wide Input DC/DC Converter
2011/04/05 KDC_WPC03.D01 Page 2 of 3
WPC03