Specifications of UCP-12/5-D24

No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
60W
Output Voltage
12V
Output Current
5A
Approval Bodies
EN, UL
Supply Voltage
24V
Dc / Dc Converter Case Style
Half Brick
Dc/dc Converter Mounting
SMD
Product
Isolated
Output Power
60 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
5 A
Isolation Voltage
1.5 KV
Package / Case Size
Half Brick
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
www.murata-ps.com
Features
OBSOLESCENCE
Standard "half-brick" confi guration
UL/EN60950 safety approvals
(BASIC insulation)
(36-75V inputs)
Fully isolated, 1500Vdc guaranteed
Output voltages: 12 or 15 Volts
V
Full 40-75 Watt output power
Reliable SMT-on-pcb construction
Input under and overvoltage shutdown
Output current limiting and
short-circuit protection
On/off, V
Modifi cations and customs for OEM’s
TARGETED FOR
IN
See page 2 for details.
ranges: 10-18V, 18-36V, 36-75V
mark for "D48" models
ON/OFF
CONTROL
OUT
(3)
+V
–V
trim and sense functions
(4)
(1)
IN
IN
COMPARATORS
UVLO & OVLO
DC/DC Converters now comes to you in the standard "half-brick" confi guration (2.3"
x 2.4" x 0.52"). All models in our new UCP Series meet UL/EN60950 safety require-
ments, including each European country’s deviations. A CB Test Certifi cate/Report
is available. All models have BASIC insulation; guarantee 1500Vdc isolation; and
because they are designed with Class B thermal insulation, satisfy all safety require-
ments over their full operating temperatures.
applications. Their "semi-synchronous-rectifi er" design (400kHz switching) achieves
impressive effi ciencies (up to 88%). Output voltages are 12 or 15 Volts. Input
voltage ranges are 10-18V ("D12" models), 18-36V ("D24" models) or 36-75V
("D48" models). "D48" models meet the Low Voltage Directive (LVD) and carry the
CE mark.
bly to construct the UCP’s proven SMT-on-pcb designs. All models have been rigor-
ously qualifi ed (including a 500-hour life test) and EMC characterized. Devices are
housed in metal cases (with non-conductive baseplates) that incorporate threaded
inserts for add-on heat sinks and/or pcb mounting.
current limiting, short-circuit protection, and thermal shutdown. Additionally, all
devices have output trim capability and an on/off control pin that can be ordered
with either polarity. We can easily modify standard-product UCP’s to meet your
application-specifi c requirements.
www.murata-ps.com
The high effi ciency, low noise and long-term reliability that defi nes DATEL
UCP Models are designed for demanding telecom, datacom and networking
For high reliability and affordability, DATEL utilizes high-speed automatic assem-
UCP’s feature input pi fi lters, input undervoltage and overvoltage lockout, output
CONTROLLER
Figure 1. Simplifi ed Schematic
PWM
CONTROL
➀ The On/Off Control function can be ordered with either positive (standard) or negative polarity.
➁ 12V- and 15V-output models have a standard forward architecture in which this FET is replaced
SWITCH
with a Schottky diode.
ISOLATION
OPTO
UL/EN Approved "Half-Brick" 40-75 Watt, DC/DC Converters
40-75 Watt, DC/DC Converters
UL/EN Approved, "Half-Brick"
Click here for possible alternative product.
REFERENCE &
ERROR AMP
Technical enquiries email: sales@murata-ps.com, tel:
Single Output
10Ω
10Ω
UCP Models
MDC_UCP40-75W.B03 Page 1 of 7
UCP Models
+SENSE
–SENSE
TRIM
+V
–V
(7)
(5)
(9)
OUT
OUT
(6)
(8)
Typical topology is shown
+1 508 339 3000

Related parts for UCP-12/5-D24

UCP-12/5-D24 Summary of contents

Page 1

... The high effi ciency, low noise and long-term reliability that defi nes DATEL DC/DC Converters now comes to you in the standard "half-brick" confi guration (2.3" x 2.4" x 0.52"). All models in our new UCP Series meet UL/EN60950 safety require- ments, including each European country’s deviations Test Certifi cate/Report is available. All models have BASIC insulation ...

Page 2

... OBSOLETE UCP-5/10-D12 5 10 OBSOLETE UCP-5/12-D24 5 12 TARGETED UCP-5/12-D48 5 12 OBSOLETE UCP-5/15-D48 5 15 OBSOLETE UCP-12/4.2-D12 12 4.2 TARGETED UCP-12/5-D24 12 5 TARGETED UCP-12/5-D48 12 5 TARGETED UCP-15/3.3-D12 15 3.3 TARGETED UCP-15/4-D24 15 4 TARGETED UCP-15/4-D48 NRND ➀ Typical +25°C under nominal line voltage and full-load conditions unless otherwise noted. ...

Page 3

... Volts, limited duration 18 Volts, limited duration Current limited. 12/15V devices can withstand an output short circuit for a brief duration only. 3.3/5V devices can withstand output shorts indefi nitely. –40 to +105°C +300°C Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UCP40-75W.B03 Page ...

Page 4

... Figure 3b. Temperature Derating With HS-CP Heat Sink Natural Convection Cooling 150 Linear Feet Per Minute 300 Linear Feet Per Minute Ambient Temperature (°C) Figure 4b. Temperature Derating With HS-CP Heat Sink Technical enquiries email: sales@murata-ps.com, tel: MDC_UCP40-75W.B03 Page 100 100 100 +1 508 339 3000 ...

Page 5

... As shown in Figure 5, the control pin is referenced to the –Input (pin 1) and has an internal pull-up resistor (28.7k: 75k: and 100k: respectively for D12, D24 and D48 models) to the +Input (pin 4). The standard UCP converter is designed so that it is enabled when the control pin is left open and disabled when the control pin is pulled low (to less than +0.8V relative to – ...

Page 6

... If you are using both the external Trim and Sense functions, you must not attempt to force the converter output voltage more than 5% above its initial, "untrimmed" value. When UCP DC/DC Converters are tested for output accuracy during fi nal test, the Sense pins are connected directly to their respective output pins. Case Connection Unlike most other DC/DC converters, UCP DC/DC's do not have their metal case connected to one of their input pins. The " ...

Page 7

... Both models are shipped with 0.009" sellf-adhesive thermal pad and mounting screws. Note: When mounting the heat sink to the UCP converter: 1. Maximum applied torque is 2 in-lbs. 2. Minimum thread engagement of the mounting screws is 12mm deep. ...

Related keywords