Features Output Current up to 16A or 45W max 12V +5/-10% input Load Regulation ±0.5% Factory set to 1.2V Output with Output Trim up to 5.0V High Efficiency to 90% Back Bias Protection Short Circuit Protection MTBF 4.2 million ...
Page 2
Ordering Information Model Number Input Voltage 12 = 12V Mechanical Options 2 = Vertical Top Side pins (Standard Horizontal Bottom Side Pins Pin Assignments CONNECTOR J1 Set Point Resistor Table Ambient conditions: 400 LFM and 50°C Output Set ...
Page 3
Outline Drawings Vertical Mount Option (S016-1220120-FB) Horizontal Mount Option (S016-1240120-FB www.murata-ps.com .100 ± .020 13 11 S016_084-S016-00 12V Input, 1.2 - 5.0V Adjustable Output, 16A or 45W 1. Dimensions are in inches and (millimeters). 2. Tolerances: (unless otherwise ...
Page 4
Efficiency Curves at 25°C 92.00% 89.00% 86.00% 83.00% 80.00% 77.00% 74.00% 71.00% 68.00% LOAD % 1.2 25% 76.66% 50% 78.04% 75% 74.04% 100% 69.58% Derating Curves Derating Curves 14.00 12.00 10.00 8.00 6.00 4.00 2.00 0.00 20.00 40.00 60.00 80.00 ...
Page 5
PWRGD - Power Good Signal The power good signal will be asserted, driven high, by the converter to indicate that the output is valid. If the output fails the specified DC voltage regulation limits or the output is below 90% ...
Page 6
DC Voltage Regulation The DC output voltages will remain within the regulation ranges shown in the following table when measured at the load end of the connector. Connect Set Resistor per table below from Trim (Pin4) to Ground (Pin7). Regulation ...
Page 7
Output Ripple and Noise The following output ripple/noise requirements will be met throughout the load ranges specified and under all input voltage conditions specified. Ripple and noise are defined as periodic or random signals over the frequency band of 10Hz ...
Page 8
Input and Output Capacitance The power supply requires the following capacitance (or equivalent) on the PWB. Output Level +5V +3.3V +2.5V +1.8V +1.5 1.25V 1.2V * Input Ceramic Capacitance > 4.7μF located close to the module ** Output Ceramic Capacitance ...