PCM80PS12 XP POWER, PCM80PS12 Datasheet

PSU, EXT, PLUG-IN, 12V, 80W

PCM80PS12

Manufacturer Part Number
PCM80PS12
Description
PSU, EXT, PLUG-IN, 12V, 80W
Manufacturer
XP POWER
Datasheet

Specifications of PCM80PS12

Power Supply Output Type
Fixed
Power Rating
80W
Input Voltage
90V AC To 264V AC
Output Voltage
12V
Output Current
6.7A
Output Connector
8 Pin DIN
Power Supply Mounting
Desktop
Output Type
Fixed
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
50/80/120 Watts
PCM Series
Specification
Output
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • 180 µA max at 132 VAC/60Hz
Output Voltage
Minimum Load
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 112-132% with auto recovery on V1
Overcurrent Protection • 110-200% with auto recovery
Temperature
Coefficient
• 90-264 VAC
• 47-63 Hz
• PCM50:
• 30 A at 115 VAC or
• PCM50: 0.55 typical
• See tables
• No minimum load required for single
• 2 s max
• 10 ms min at low line
• ±1% max at full load for ±10% change
• ±5% max
• 5% max. deviation, 500 µs recovery time
• 2% pk-pk, 20MHz BW
• ±0.05% /˚C
PCM80:
PCM120:
60 A at 230 VAC at 25 ˚C cold start
PCM80/120: 0.94 min
300 µA max at 264 VAC/50Hz
output models. See tables for multi
output models
in input
for a 50% load change
on all outputs
1.35 A max
1.30 A max
1.60 A max
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • PCM50: 0 ˚C to +70 ˚C, derate from 100%
Storage Temperature
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Power Frequency
Magnetic Fields
Dips & Interruptions
Safety Approvals
4000 VAC Isloation
Low Leakage Current
Single, Dual and Triple Outputs
Worldwide Medical Approvals
CCC Approved (PCM80)
Both Line and Neutral Fused
Non-standard Connectors Available
• Single output models: 80% typical
• 4000 VAC Input to Output
• PCM50: 64 kHz typical
• 100 kHrs at full load and 25 ˚C ambient
• PCM50/80: -40 ˚C to +80 ˚C
• EN55022, level B conducted
• EN61000-3-2, class A
• EN61000-3-3 amendments 1 & 2
• IEC61000-4-2, level 3
• IEC61000-4-3 10 V/m, level 3
• IEC61000-4-4, level 3
• IEC61000-4-5, level 3
• IEC61000-4-6 10 V/m, level 3
• IEC61000-4-8 10 A/m, Perf Criteria B
• IEC61000-4-11, 30% 500 ms,
• UL60601-1, CSA C22.2 No. 601.1 per cUL
Multi output models: 75% typical
1500 VAC Input to Ground
500 VAC Output to Ground
PCM80: 55 kHz typical
PCM120: 120 kHz typical
per MIL-HDBK-217F
load at 50 ˚C to 50% load at +70 ˚C
PCM80: 0 ˚C to +70 ˚C, derate from 100%
load at 40 ˚C to 50% load at +70 ˚C
PCM120: 0 ˚C to +60 ˚C, derate from
100% load at 40 ˚C to 50% load at +60 ˚C
PCM120: -20 ˚C to +85 ˚C
EN55022, level B radiated
Perf Criteria B
Perf Criteria B
Perf Criteria B
Perf Criteria B
Perf Criteria B
60% 100 ms, 100 % 5000 ms
Perf Criteria A, A, C
EN60601-1, CCC (PCM80)
xppower.com

Related parts for PCM80PS12

PCM80PS12 Summary of contents

Page 1

Watts PCM Series Specification Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • PCM50: 1.35 A max PCM80: 1.30 A max PCM120: 1.60 A max Inrush Current • 115 VAC or ...

Page 2

Models and Ratings Maximum Output Voltage Output Power Output 1 Output Power Vnom Imin Imax Tol. ...

Page 3

... PIN DIN PLUG PCM80 Output 3 Number Vnom Imin Imax Tol. (1) PCM80PS3V3† PCM80PS05†* PCM80PS07† PCM80PS09†* PCM80PS10 PCM80PS12†* PCM80PS13V5† PCM80PS15†* PCM80PS16 PCM80PS17V5 PCM80PS18†* PCM80PS24†* PCM80PS27†* PCM80PS30 PCM80PS36 PCM80PS48†* PCM80PD00 PCM80PD01 PCM80PD02 PCM80PD03 ...

Page 4

Models and Ratings Maximum Output Voltage Output Power 108 W 113 W 120 W 120 W 120 W Notes 1. Peak current is 5 seconds maximum duration with a 10% duty cycle. † Available from Farnell InOne. See pages 236-237 ...