STV 400K-27Y SOLA HEVI DUTY, STV 400K-27Y Datasheet

Suppressor

STV 400K-27Y

Manufacturer Part Number
STV 400K-27Y
Description
Suppressor
Manufacturer
SOLA HEVI DUTY
Series
STV 200/400Kr
Datasheet

Specifications of STV 400K-27Y

Suppressor Type
Transient Voltage
Voltage Rating
480VAC
Output Current
15A
Operating Voltage Range
277VAC To 480VAC
Peak Surge Current
200kA
Response Time
0.5ns
Protection Mode
L-N, L-G, N-G
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power Protection and Conditioning
Surge Protection and Active Tracking
Filtering
®
Introduction .........................................................................10
STV 200/400K Single and Three Phase Series ....................11
STV 100K Single and Three Phase Series ............................14
STV 25K DIN Rail Mount Series ...........................................16
STF Series Active Tracking
Filters .......................................18
®
STFV Plus Series Active Tracking
Filters with
®
1
Surge Protection ..................................................................21
STFE Elite Series Active Tracking
Filters with
®
Surge Protection ..................................................................24
STC Series of Data/Signal Line Surge Protection .................27
Power Conditioning
CVS Hardwired (± 1% Output Regulation) ........................... 34
Design Styles ....................................................................... 35
MCR Hardwired (± 3% Output Regulation) ........................... 36
Connection Diagrams .......................................................... 38
MCR Portable (± 3 Output Regulation) ................................. 40
Model Comparison/BTU Output Chart ................................. 42
Operating Characteristics ................................................... 43
SOLATRON™ Plus Three Phase Power Conditioners ......... 46
Frequently Asked Questions .............................................. 237
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
9
9

Related parts for STV 400K-27Y

STV 400K-27Y Summary of contents

Page 1

... Filters with ® Surge Protection ..................................................................21 STFE Elite Series Active Tracking Filters with ® Surge Protection ..................................................................24 STC Series of Data/Signal Line Surge Protection .................27 Power Conditioning CVS Hardwired (± 1% Output Regulation) ........................... 34 Design Styles ....................................................................... 35 MCR Hardwired (± 3% Output Regulation) ........................... 36 Connection Diagrams .......................................................... 38 MCR Portable (± 3 Output Regulation) ................................. 40 Model Comparison/BTU Output Chart ...

Page 2

... Today's industries depend on their telecommunication, networking, computing and production equipment for optimized manufacturing performance. SolaHD's proven surge protection and filtering devices protect these critical operations across facilities from the continuous threat of transient spikes, noise and harmonic distortion. Employing an entire facility protection strategy will safeguard the electrical system against most transients ...

Page 3

... Uninterruptible Power System • Transformers • STV 25K, STV 100K, STF, STFV and STC Series Selection Table Catalog Number STV 400K-10Y STV 200K-10Y STV 400K-27Y STV 200K-27Y STV 400K-48D STV 200K-48D Visit our website at www.solahd.com. Input Voltage 120/208 V Three Phase Wye 4 wire + Ground ...

Page 4

... Circuit Ampacity Limitations 200 kA 200 kA 100 kA N/A 100 kA 100 kA 100 kA 100 kA 100 kA N/A 5 year limited warranty Visit our website at www.solahd.com. STV 400K-10Y STV 400K-27Y STV 400K-48D 120Y/208 V 277Y/480 V Three Phase Wye, Three Phase Delta 400 V 700 V 700 V 1,500 V 400 V 700 V 400 V ...

Page 5

... STV 200K 16.25 14.25 8.25 STV 400K Dimensions (inches) Catalog Number 16.25 14.25 8.25 STV 200K 16.25 14.25 8.25 STV 400K Contact Technical Services at (800) 377-4384 with any questions. Power Protection and Conditioning C D STV 200/400K Series Weight Suggested lbs (kg) Breaker Size ...

Page 6

Power Protection and Conditioning The STV 100K Series - Surge Protective Devices SolaHD’s STV 100K series is a hardwired surge protective devices are designed for installation at the service entrance, branch panel or a dedicated sensitive electronic load. These units ...

Page 7

STV 100K Specifications Description STV 100K-10S STV 100K-10N STV 100K-24L STV 100K-10Y STV 100K-23Y STV 100K-27Y STV 100K-24D STV 100K-48D STV 100K-10D4 STV 100K-24D4 120/240 V 120 V Input Vac Single Phase Single Phase 3 wire + Ground 2 wire ...

Page 8

... Low clamping levels for more effective protection. • Easy access terminal screws for quick mounting and installation. • 50,000 amps of surge protection. • Sine wave tracking and all mode protection provide consistent and reliable protection on all electrical paths. • Patented thermal fusing prevents MOV overheating caused by excessive current levels ...

Page 9

STV 25K Specifications Description Input Voltage Maximum Continuous Operating Voltage (MCOV) Line Frequency Connection/Mounting Type Input Current Rating Phase Configuration Weight - lbs (kg) Dimensions ( Modes of Protection Safety Agency Approvals UL 1449 (2nd Edition) ...

Page 10

Power Protection and Conditioning STF Series – Active Tracking Filters ® Low voltage/high frequency noise is caused by everyday events such as turning on machinery, motors, or equipment. Although noise is less dramatic than high voltage transients, the long term ...

Page 11

Selection Table Catalog Min. Wire Size Amps Number (AWG Suggested) 2.5 26 STF0025-10N 5.0 22 STF0050-10N 7.5 18 STF0075-10N 15.0 14 STF0150-10N 20.0 12 STF0200-10N 30.0 10 STF0300-10N 2.5 26 STF0025-24L 5.0 22 STF0050-24L 7.5 18 STF0075-24L 15.0 14 STF0150-24L ...

Page 12

Power Protection and Conditioning STF Specifications Description Input Voltage Line Frequency Transient Attenuation Response Time Mean Time Between Failure (MTBF) Packaging Operating Temperature Load Surge Current Rating Transient Reduction Safety Warranty Dimensional Drawings Design Style 1 Design Style 3 Contact ...

Page 13

... STFV Plus Series – Active Tracking The SolaHD STFV Plus Series combines Active Tracking filtration for low energy noise and surge protection for high energy transients. It continuously tracks the input AC power line responding instantly into action upon detecting extrane- ous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, motors, or equipment ...

Page 14

Power Protection and Conditioning Selection Table Catalog Case Dim. (in) Amps Number 2.5 4.0 x 2.88 x 1.81 STFV025-10N 5.0 4.0 x 2.88 x 1.81 STFV050-10N 7.5 4.75 x 4.75 x 2.35 STFV075-10N 15.0 6.25 ...

Page 15

STFV Specifications Description Input Voltage Line Frequency Configuration Response Time Enclosure Fusing Status Indication Connection/Mounting Type Operating Temperature Operating Humidity Mean Time Between Failure (MTBF) Packaging Peak Surge Current Capability ( µs) Load Surge Current Rating Frequency Response ...

Page 16

... Power Conditioners • Uninterruptible Power System • Power Supplies Contact Technical Services at (800) 377-4384 with any questions. 24 Filters with Surge Protection ® Features • Series connected DIN Rail mounted filter • Patented durable metal mount clip • UL Listed Surge current capacity – 45,000 Amps • ...

Page 17

STFE Specifications Description Input Voltage Line Frequency Response Time Enclosure Fusing Status Indication Connection/Mounting Type Operating Temperature Weight (Kg) Dimensions - in (mm Operating Humidity Peak Surge Current Capability Load Surge Current Rating Frequency Response ...

Page 18

Power Protection and Conditioning Dimensional Diagram 2.560 L/L1 N/L2 Active Tracking Filter STFE Elite Series 4.880 NO COM NC L/L1 N/12 Internal Diagram Rear View DIN Connector Strong all metal for horizontal or vertical mounting fast responding surge suppressor Contact ...

Page 19

... STC Series – Data/Signal Line Surge Protection Devices for Transient Data The rapid development of automated controls, telecommu- nications and fire/security systems has made it imperative to have properly coordinated low-voltage protection. Modern networked industrial facilities require error free transmission of information for maximum productivity and integrity of data. ...

Page 20

Power Protection and Conditioning STC-P0E Series, Category 5 and 6 Power-over-Ethernet Applications The SolaHD STC Power-over-Ethernet (PoE) series is designed to work on Category 5 P0E transmission lines as well as Category 6 applications. They feature both female to female ...

Page 21

... Three electrically tied ground terminals are provided for grounding the unit to building-approved ground. The shield is isolated from ground. Features • Low-Voltage Data Surge Protection • Three-Stage Hybrid Technology • Sneak/Fault Current Protection With Resetable Fuses (PTCs) • Low Profile Packaging • ...

Page 22

Power Protection and Conditioning STC-642 Series, Data/Signal Line Protection The STC-642 series of surge suppressors are dual pair (four wire) modules using three-stage hybrid technology. This module addresses over voltage transients with gas tubes and silicon avalanche components. In addition, ...

Page 23

STC-642 Series, Data/Signal Line Protection Wiring Diagram (PIN Assignments) Ground Terminal (internally tied together) to building approved ground. The STC-PCB1B accommodates AWG wire. The hybrid design of this product includes series resistance. Do not ...

Page 24

Power Protection and Conditioning STC-CCTV Coax Series The STC-CCTV Series is tailored specifically to CCTV, data, audio and cable applications. These units are single Coax Surge Protective Devices implementing three-stage hybrid technology. They address overvoltage transients with a primary gas ...

Page 25

STC-TEL Series – RJ Connection Telephone Protection The SolaHD STC-TEL series are single pair telephone or Data Line Protectors that use an advanced two-stage hybrid design. These units address over voltage transients with silicon breakover devices, while sneak and fault ...

Page 26

... Features • Superior voltage regulation of ±1% • Surge protection tested to ANSI/IEEE C62.41, Class A & B Waveform • Harmonic filtering • Hardwired • Acts as a Step-up/Step-down Transformer • Galvanic isolation provides exceptional circuit protection. • ...

Page 27

Specifications Parameter Voltage Current 1 Frequency Line Regulation Overload Protection Output Harmonic Distortion Noise Attenuation Efficiency Storage Temperature Operating Temperature Audible Noise Approvals Warranty Notes Consult user manual for fuse sizing Applies to all models except ...

Page 28

... Power Protection and Conditioning MCR Hardwired Series – Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHD’s patented ferroresonant design, the MCR can increase the actual Mean Time Between Failure (MTBF) of protected equipment ...

Page 29

Selection Tables: Single Phase Group 3 – MCR Series Only VA Catalog Number Voltage Input 500 63-31-150-8 1000 63-32-210-8 2000 63-32-220-8 3000 63-32-230-8 5000 208, 240, 480, 600 63-29-250-8 7500 208, 240, 480, 600 63-29-275-8 10000 208, 240, ...

Page 30

Power Protection and Conditioning Electrical Connections A Primary Voltage Interconnect Connect Lines 208 H1 & 240 H1 & 480 & H6 ...

Page 31

Electrical Connections E Primary Voltage Interconnect Connect Lines To 120 H1 & H2 208 H1 & H3 240 H1 & H4 480 H1 & H5 Secondary Voltage Interconnect Connect Lines To 120 X1 & & X2 208 ...

Page 32

... Features • ±3% output voltage regulation • Noise attenuation - 120 dB common mode - 60 dB transverse mode • Surge protection tested to ANSI/IEEE C62.41 Class A & B Waveform (<10 V let-through typical) • Harmonic filtering • Galvanic isolation provides exceptional circuit protection. • Point-of-use Protection (cord & plug connected) - Easy & ...

Page 33

Selection Tables: Single Phase Group A – MCR Portable Series Only Catalog Voltage VA Number Input/Output 70 120 63-13-070-6 150 120 63-13-115-6 250 120 63-13-125-6 500 120 63-13-150-6 750 120 63-13-175-6 1000 120 63-13-210-6 1500* 120 63-13-215-6 2000** ...

Page 34

... No loss of output for line loss of 3 msec. Overload Output Harmonic Distortion 40 dB common and normal code. Noise Isolation Up to 6000 Volt surges are suppressed to a let through of less than 1% per ANSI/IEEE Surge Protection C62.41 Class A & B waveforms. Efficiency Operating Temperature Audible Noise Listed to UL 1012. CSA Certified ...

Page 35

Operating Characteristics of the CVS & MCR Series Regulation SolaHD’s CVS power conditioners will hold output voltages to ±1.0% or less with input variations as great as ±15% (115V ±15% or 120 V +10%/-20%). Units operated at less than rated ...

Page 36

Power Protection and Conditioning Operating Characteristics of the CVS & MCR Series Figure C: Power Factor Efficiency The copper magnet wire and lamination material used in SolaHD ferroresonant products are selected to achieve efficiencies of 90% or higher. Whether or ...

Page 37

... These features are not provided by standard surge protection devices but are often misrepresented or misused by SPD manufacturers trying to market their product as a “Do All” power quality device. ...

Page 38

... Tight regulation for protection against sag (-25%) and swell (+15%) conditions • Fail-safe, no-break, auto-bypass • Status indicating lights • Shielded, copper wound isolation transformer • Surge protection to ANSI/IEEE and IEC Standards • High efficiency (96%) microprocessor controlled tap switcher • Automatic under voltage protection • UL1012, UL1449-2, ...

Page 39

... Custom Voltages Contact Technical Services at (800) 377-4384 with any questions. Power Protection and Conditioning Noise Suppression Performance Specifications Common Mode Noise Attenuation Normal Mode Noise Attenuation Surge Protection Catalog Number Vac Input 208 Vac Input, 208Y/120 Vac Output 208 63TAA320 208 63TAA330 ...

Page 40

Contact Technical Services at (800) 377-4384 with any questions. 48 Notes Visit our website at www.solahd.com. ...