TOP 100-124 TRACOPOWER, TOP 100-124 Datasheet - Page 2

PSU, OPEN FRAME, 100W, 24V/4A

TOP 100-124

Manufacturer Part Number
TOP 100-124
Description
PSU, OPEN FRAME, 100W, 24V/4A
Manufacturer
TRACOPOWER
Datasheet

Specifications of TOP 100-124

Power Supply Type
Switch Mode
Power Supply Output Type
Fixed
No. Of Output Channels
1
Input Frequency
63Hz
Output Voltage
24V
Output Current
4.2A
Power Rating
100W
Input Voltage
90VAC To 132VAC /
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input voltage range
Input frequency
Input protection
Zero load power consumption
Recommended circuit breaker
Output Specifications
Regulation
Ripple and noise (20Mhz Bandwidth)
Overvoltage protection
Power back immunity
Overload protection by current limit
Short circuit protection
Capacitive load
General Specifications
Operating Temperature
Power derating
Temperature coefficient
Reliability, calculated MTBF @ 25°C acc. to IEC 61709
Humidity (non condensing)
Efficiency
Switching frequency
Hold-up time
Start-up time
Isolation voltage
Isolation resistance (at 500 VDC)
Earth leakage current
Isolation class
Electromagnetic compatibility – Conducted input RI suppression
(EMC), emissions
– Input and Load variation
– Vin = 115 VAC
– Vin = 230 VAC
– Vin = 115 VAC
– Vin = 230 VAC
– Vin = 115 VAC
– Vin = 230 VAC
– Input / Output
– Input / Field Ground
– Output / Field Ground
– Harmonic current emissions
3.3 – 12 VDC models: >1.0 Mio h
15 – 48 VDC models: >1.4 Mio h
3.3 VDC model: 5.0 V
5.0 VDC model: 6.0 V
3.3 VDC model: 5.0 V (6.0 V for 1 sec)
48 VDC model: < 200 mVp-p
24 VDC model: 30 V
48 VDC model: 60 V
24 VDC model: 35 V (40 V for 1 sec)
48 VDC model: 63 V (68 V for 1 sec)
12 VDC model: 16 V
15 VDC model: 20 V
12 VDC model: 16 V (18 V for 1 sec)
15 VDC model: 20 V (23 V for 1 sec)
5 VDC model: 6.3 V (7 .0 V for 1 sec)
90 – 132 / 187 – 264 VAC autorange
47 – 63 Hz
T4 A/250 V internal fuse in both line & neutral
3.6 W
6 A (characteristic C) or slow blow fuse
1% max.
< 100 mVp-p
at 150 % Iout max.
foldback (automatic recovery)
10’000 µF max.
– 25°C to +70°C with derating
see graph page 3
0.02 % /K
0 – 95 % rel. H max.
89 – 91%
90 – 92%
100 kHz typ. (pulse width modulation)
10 ms typ.
15 ms typ.
< 3s
< 2s
4000 VAC
2000 VAC
500 VAC
100 Mohm min.
250 µA max.
class II double isolation
EN 55022, class B (conductive plane to be
connected to safety earth)
IEC / EN 61000-3-2, class A
AC/DC Power Supplies
TOP-100 Series
100 Watt
Page 2 of 3