81708 EATON POWERWARE/MGE OFFICE PROTECTION, 81708 Datasheet - Page 2

UPS, 120V, 1150W

81708

Manufacturer Part Number
81708
Description
UPS, 120V, 1150W
Manufacturer
EATON POWERWARE/MGE OFFICE PROTECTION
Datasheet

Specifications of 81708

Capacity (va / W)
1250VA / 1150W
No. Of Outlets
6
Input Voltage
85V AC To 153V AC
Output Voltage
120V
Backup Time - Full Load
14min
Length
508mm
Width
86.36mm
Height
439.42mm
Weight
53.6lb
Lead Free Status / RoHS Status
na
MGE
2 year guarantee,
including batteries
Standard exchange of product in case
of failure, including batteries.
Associated services:
Warranty+: 3 or 5 year extended
guarantee.
Communications software
and hardware
Solution-Pac software on CD-ROM
with each UPS
For monitoring the server(s) powered
by the UPS and for local and remote UPS
supervision.
Network Management Card (NMC) 2006
For connecting the UPS to an Ethernet
10/100 network, raising SNMP alarms and
supervising the UPS using a simple browser
interface.
NMC environmental sensor
Monitoring the temperature, humidity
and 2 relay contacts via SNMP or HTML.
Enterprise Power Manager supervisor
For comprehensive management
of a set of UPSs using a Windows PC.
Management-Pac 2 suite
NMS integration kit: HP OpenView, IBM
Tivoli Netview, CA Unicenter, etc.
Status Card • Contacts/Serial
Add a second relay contacts or Serial
port to the UPS.
UPS Control remote display
To monitor the UPS status up to 80 feet
from the unit.
MGE
North & South America Headquarters
13 Whatney, Suite 101 • Irvine, CA 92618
tel (800) 279-7776 • fax (949) 268-2847
Office Protection Systems
Customer Service & Support
2
Evolution 850 VA
1
6
3
8
www.mgeops.com
Evo
revision 201
effective October 2007
Technical characteristics
1: Up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software.
2: USB and RS232 ports cannot be used simultaneously. 3: Runtime at 0.7 Power factor.
* NMC card included in Netpack versions.
Part Numbers
Model
Rating
Format
Electrical characteristics
Technology
Input voltage and frequency
ranges without using
batteries
Output voltage and frequency
Connections
Input
Remotely, individually
controlled receptacles
Batteries
Typical backup times for 50 and 70% load (in minutes)
Battery management
Interfaces
Communication ports
Communications card slot
Operating conditions, standards and approvals
Operating temperature
Noise level
Performance - Safety - EMC
Approvals
Dimensions (WxHxD) in inches / Weight in lbs
Dimensions of the Tower
Dimensions of the Rack
Tower Weights
Rack Weights
Dimensions of EXB
EXB Weights
Output
Evolution
Tower
Rack1U
Versatile (2U) Twr/Rck
EXB Models
1
2
3
4
5
6
7
8
Full user interface:
- ON/OFF button for UPS and outlets
- Load protected/ not protected LED
- Utilized power level/Battery charge level
- Status of switchable outlets
Panel for replacing batteries without
interrupting the output.
1 USB port + 1 serial port + remote
ON/OFF and emergency stop inputs.
EXB battery unit connector.
EXB units recognized automatically.
(4) 5-15R, including
2 programmable receptacles.
(6) 5-15/20R, including
2 programmable receptacles.
Communications card slot.
Standard UPS
Rack mount (1U)
Rack/Tower Versatile (2U)
81700
81701
650
-
-
81703
81704
850
17.2" x 14.4"
(Performance), IEC/EN 61000-4-2, 61000-4-3, 61000-4-4; 61000-4-5, 61000-4-6, 61000-4-8 (EMI)
1.7"(1U) x 1.7"(1U) x 17.2" x 20.2" 1.7"(1U) x
18.5 lbs 23.9 lbs 27.6 lbs 36.4 lbs 56.7 lbs 53.6 lbs 58.6 lbs 74.5 lbs
22.3 lbs 35.5 lbs 36.6 lbs 44.1 lbs 56.7 lbs 53.6 lbs 58.6 lbs
650 VA
-
-
420 W
650
9/6
IEC/EN 62040-1-1 (Safety), IEC/EN 62040-2 EN 50091-2 class A (EMC), IEC/EN 62040-3
9.2" x 5.8" x 16.5"
32º to 95º F
81705
81706
1150
of external battery units => continuous maximization of backup time
Tower or 1U Rack
850 VA 1150 VA 1440 VA 1920 VA 1250 VA 1750 VA 2500 VA 2880 VA
600 W
+ 1 mini terminal block for remote ON/OFF and Remote Power Off
-
-
E N E R G I Z E
850
Automatic weekly test (period adjustable), automatic recognition
16/7
56.5 to 70 Hz (60 Hz system)
< 40dbA
Evolution
(4) 5-15R
(2) 5-15R
5-15P
1 USB port + 1 RS232 serial port and relay contacts
81709
81710
1550
Line-Interactive High Frequency (Booster + Fader)
(3)
770 W 1100 W 1600 W 1150 W 1600 W
-
-
1150
14/7
or NMC ModBus/JBus or MC Contacts/Serial
-
-
-
-
120V (+6/-10 %)
8
89V-151V (adjustable to 80V-153V)
1 slot for NMC Minislot 2006 card
17.2" x 21.9"
81712
2000
RT2U
9.2" x 5.8" x
+ deep discharge protection
1550
Evolution S 1250VA
19.4"
14/8
-
-
-
3
5
UL, cUL, CE, CB report
2
S 1250
81708
RT2U
56.7 lbs 53.6 lbs 58.6 lbs
5-15/20R
5-15/20R
(2)
2000
5-20P
14/7
-
-
/ 50/60 Hz +/- 0.1 %
(6)
(2)
(1)
3.4"(2U) x 17.3" x 20"
81713
Y O U R
/ 47 to 70 Hz (50 Hz system)
UPS -
RT2U (tower / rack 2U)
< 45 dBA
S 1750
81711
300/200 180/115 290/200 210/135
RT2U
105/60
3.4"(2U) x 17.3" x 20"
1250
5-15P
5-15R 5-15/20R
5-15R
20/14
32º to 104º F
-
-
(6)
(2)
67 lbs
4
S 2500
81714
Evolution S
RT2U
5-20P
60/36
1750
Evolution
14/9
81717 (RT2U) or 81707
(6)
-
-
1
E N T E R P R I S E
(2) 5-15/20R
(2)
7
3.4"(2U) x 17.3" x 25"
5.1"(3U) x 17.3" x 19.1"
S 3000
5.1"(3U) x 17.3" x 19.1"
(RT3U)
2250 W 2700 W
81716
RT3U
85/55
2500
(6) 5-15/20R + (1)
17/11
-
-
< 50 dBA
91.9 lbs
L5-30P
L5-30R
S 3000
& RT3U
81715
74.5 lbs
75.6 lbs
RT2U
3000
60/42
RT2U
15/10
-
-

Related parts for 81708