DCA5-20PC-7-DC4-RL-C Murata Power Solutions Inc, DCA5-20PC-7-DC4-RL-C Datasheet - Page 2

DC Ammeter 25/250A Ext. Shunt

DCA5-20PC-7-DC4-RL-C

Manufacturer Part Number
DCA5-20PC-7-DC4-RL-C
Description
DC Ammeter 25/250A Ext. Shunt
Manufacturer
Murata Power Solutions Inc
Type
LED-Display, Subminiature DC Ammetersr
Datasheet

Specifications of DCA5-20PC-7-DC4-RL-C

Equipment Type
LED-Display, Subminiature DC Ammeters
Input
50 mV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance/Functional Specifi cations
Typical at T
➀ A full-scale input voltage of 50.00mV is used to calibrate all models for their designated
Input (TB1) ➀
Full Scale Input ➀
Overvoltage Rating ➁
Input Impedance
Shunt Input to Power Supply Isolation ➂
DCA-20PC-X-DC4 models only
Performance
Sampling Rate
Accuracy
Zero-Current Reading ➃
Temperature Drift (0 = +60°C)
Power Supply Voltage (TB2)
DCA-20PC-X-DC1-XX
DCA-20PC-X-DC4-XX
Power Supply Current ➄
DCA-20PC-X-DC1-XX (@ 5-40V)
DCA-20PC-X-DC4-XX (@ 8V)
DCA-20PC-X-DC4-XX (@ 36V)
TB1 and TB2 Terminal Blocks
Wire Size
Insulation Strip Length
Screw Tightening Torque
Rated Current
Display
Display Type and Size
Overrange Indication
Display Reading/Decimal Point
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Case Material
Dimensions
Weight
Measuring positive and negative currents (bipolar operation): In applications
measurement range. The ammeter’s rear calibration potentiometer compensates for
full-scale input variations up to ±1% (49.5 to 50.5mV).
where both positive and negative currents must be measured, Murata Power Solu-
tions recommends using ‘-DC4’ 8-36V isolated supply models. Negative current
fl ow is denoted by the illumination of the display’s negative (–) sign; the absence of
a negative sign implies positive current fl ow. Contact MPS if you have any questions
regarding bipolar operation of DCA5-20PC ammeters.
A
= +25°C, unless otherwise noted.
“–001”
3½ digit, 0.37"/9.4mm high red, blue or
Min.
±400
+5.0
49.5
500
–20
+8
20A with 12AWG solid copper wire;
0
0
15A with 14AWG solid or stranded
1.38"W x 0.88" x 1.0" nominal
16-22AWG, solid or stranded
3.6 pound/inches (0.4Nm)
"–1_ _ _" for negative Vin
"1_ _ _" for positive Vin
2.5 reading per second
0.6 ounces (17 grams)
Model dependent
Typ.
“000”
±0.2
100
Polycarbonate
50
1K
10
25
0.250 inches
green LED
±0.15%FS
copper wire
Max.
“001”
50.5
±0.4
+40
+36
150
+60
+75
15
40
85
www.murata-ps.com/dpm
Cnts/°C
Units
Counts
Ohms
mAdc
mAdc
mAdc
mV
Vdc
Vdc
Vdc
mV
°C
°C
%
Input Range:
1 = 5.00A/50.0A/500A
2 = 1.000A/10.00A/100.0A/1000A
3 = 30.0A/300A
4 = 75.0A/750A
5 = 15.00A/150.0A/1500A
6 = 1.999A/19.99A/199.9A/1999A
7 = 25.0A/250A
8 = 400A
9 = 600A
10 = 80.0A/800A
11 = 1200A
Ordering Information
DCA5-20PC - 1 - DC1 - R L - C
➁ On non-isolated ‘-DC1’ models, continuous application of single-ended ±400mV
➂ Breakdown (isolation) voltage applies only to ‘-DC4’ isolated-power models.
➃ Zero reading is measured with TB1-1 (–IN) shorted to TB1-2 (+IN).
➄ Power supply currents noted are measured with the 50mV shunt input (TB1) at
➅ Each model’s full-scale display reading with a 50.0mV input is designated by the
Power Supply:
Reading w/
*
inputs will not damage the ammeter. Single-ended inputs are defi ned as those
whose TB1-1 (–IN) potential is within ±0.1V of the potential on TB2-2 (-V). For
all models, the application of short-duration (5 seconds max.) ±1V inputs will not
damage the ammeter.
Breakdown voltage is tested with TB1-1 tied to TB1-2 (–IN shorted to +IN) and
TB2-1 tied to TB2-2 (+V shorted to -V). 500Vdc is then applied between the
two shorted terminal-block pairs; the max. allowable leakage current is 5uA.
zero volts (display reads “000”) and one decimal point enabled.
fi rst X in the DCA5-20PC-X-XXX model number structure. Decimal point selection
(DP1, DP2, DP3, or none) is performed by the user to suit desired amperage range.
Input ranges -1, -2, -3, -4, -7, -8 and -9 can accommodate 100mV shunts. For these
ranges, the indicated 50mV reading is doubled when a 100mV input is applied.
Accessories:
With respective decimal point user enabled. See technical note 7.
DMS-20-CP Panel Cutout Punch
A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each ammeter
Shunt Model
3020-01097-0
3020-01107-0
3020-01098-0
3020-01096-0
3020-01099-0
3020-01108-0
3020-01100-0
3020-01101-0
3020-01102-0
3020-01103-0
3020-01104-0
3020-01105-0
3020-01106-0
DC1 = +5-40Vdc, non-isolated power
DC4 = +8-36Vdc, isolated power
(available with -RL, -BL, or -PGL LEDs)
(available with -RL, -BS, or -GS LEDs)
50mV Shunt
Rating
5A/50mV
10A/100mV
20A/50mV
50A/50mV
100A/50mV
100A/100mV
150A/50mV
200A/50mV
300A/50mV
500A/50mV
800A/50mV
1000A/50mV
1200A/50mV
50mV & 100mV Input, LED-Display,
*
03 May 2010 MPM_DCA5-20PC.B06 Page 2 of 6
DCA5-20PC Series
Subminiature DC Ammeters
Reading w/ 100mV Shunt
10.00A/100.0A/1000A
1.999A/19.99A/199.9A/1999A
60.0A/600A
15.00A/150.0A/1500A
N/A
N/A
5.00A/50.0A/500A
80.0A/800A
120.0A/1200A
N/A
N/A
Use with
DCA5-20PC-1
DCA5-20PC-1
DCA5-20PC-6
DCA5-20PC-1
DCA5-20PC-2
DCA5-20PC-1
DCA5-20PC-5
DCA5-20PC-6
DCA5-20PC-3
DCA5-20PC-1
DCA5-20PC-10
DCA5-20PC-2
DCA5-20PC-11
email: sales@murata-ps.com
LED Color:
BL = Low-Power Blue
BS = Super Blue
GS = Standard Green
PGL = Low-Power Green
RL = Low-Power Red
Add -C for RoHS
*

Related parts for DCA5-20PC-7-DC4-RL-C