DT80PW090C TDK Corporation, DT80PW090C Datasheet

no-image

DT80PW090C

Manufacturer Part Number
DT80PW090C
Description
AC-DC, Adapter, Input 115-230VAC, Output 9V 8A, 72W
Manufacturer
TDK Corporation
Series
DT80-Cr
Datasheet

Specifications of DT80PW090C

Form
Desktop (3 Prong without Cord)
Voltage - Output Per Connector
9VDC
Current - Output
8A
Voltage - Input
90 ~ 264VAC
Power - Output
72W
Transformer Type
Switching - Energy Star
Efficiency
85%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Polarization
-
Cord Plug
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
285-2020
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current
Input Current (Maximum)
Power Factor
Leakage Current (typ, 264VAC 63Hz)
Hold Up Time (Typ)
Temperature Coefficient
Voltage Accuracy
Adjustment Range
Minimum Load
Total Regulation
Ripple & Noise
Short Circuit Protection
Overvoltage Protection
Efficiency
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Vibration (non operating)
Shock
Safety Agency Approvals
California Energy Commission (CEC)
EISA
Offload Power Consumption
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxLxH)
Cable Length and Thickness
AC Input Connector
Output Connector
MTBF (MIL-HNBK), 100% load, 25C hours
Warranty
(1) EISA - Energy Independence and Security Act of 2007.
CEC and EISA Compliant
Wide Range AC Input
> 85% Efficient
MODELS
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
VAC
mm
mA
ms
yrs
°C
°C
°C
W
in
A
A
%
%
%
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DT62/80-C Series
Input to Ground 1.5kVAC, Input to Output 3kVAC (Output is connected to Ground)
62W to 80W AC-DC External Power Supplies
Kycon KPPx-4P or equivalent. Pins 1 & 2: -Vout, Pins 3 & 4: +Vout
223,933 Hours
23.52m/s
DT62PWxxx-C
0 to +40°C Full load, derate linearly to 50% load at 60°C
None
110 - 130% of nominal (Cycle input power to reset)
<50A at 230VAC input, 25°C ambient cold start
2
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
UL60950-1, EN609501-1, IEC60950-1
Benefit
Continuous - hiccup mode (110-160%)
IEC 320-C14 (Accepts IEC 320-C13)
Easier system compliance
Global Operation
Consumes less energy
CEC, & EISA
Wide Range AC Input
Power Factor Correction (DT80)
Low Profile & Lightweight
90 - 264VAC (47 - 63Hz)
EN55022-B, FCC Class B
16ms at 115VAC input
< 196.1 m/s
See model selector
See model selector
2.71 x 5.2 x 1.57
-10 to +70°C
>85% typical
10 - 90% RH
±0.05%/°C
Convection
EN55024
1050mm
One Year
< 0.5W
0.7mA
None
None
410g
±1%
±5%
2.5A
1%
(1)
Typically 0.9 at full load(Meets EN61000-3-2)
2
Compliant Models
(20G)
203,109 Hours
DT80PWxxx-C
43

Related parts for DT80PW090C

DT80PW090C Summary of contents

Page 1

DT62/80-C Series Feature CEC and EISA Compliant Wide Range AC Input > 85% Efficient ...

Page 2

... DT62/80-C Series Output Ratings Model Output (V) DT62PW090C 9 DT62PW120C 12 DT62PW150C 15 DT62PW180C 18 DT62PW240C 24 DT80PW090C 9 DT80PW120C 12 DT80PW150C 15 DT80PW180C 18 DT80PW240C OUTPUT CABLE Other AC-DC Products DTM65-C 65W CEC Compliant Medical Adapters DT100/150-C 100W to 150W CEC Compliant Adapters DTM110-C 110W CEC Compliant Medical Adapters 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324 ...

Related keywords