XG4M-5030-T Omron, XG4M-5030-T Datasheet

CONN SOCKET 50POS W/ STRAIN RLF

XG4M-5030-T

Manufacturer Part Number
XG4M-5030-T
Description
CONN SOCKET 50POS W/ STRAIN RLF
Manufacturer
Omron
Series
XG4r
Datasheets

Specifications of XG4M-5030-T

Connector Type
Receptacle
Contact Plating
Gold
Contact Material
Phosphor Bronze
Contact Type
Female Socket
Number Of Positions
50
Pitch
0.100" (2.54mm)
Number Of Rows
2
Row Spacing
0.100" (2.54mm)
Mounting Type
Free Hanging (In-Line)
Cable Termination
IDC
Wire Type
Ribbon Cable
Wire Gauge
28 AWG
Features
Feed Through; Polarizing Key, Strain Relief
Contact Finish
Gold
Contact Finish Thickness
5.9µin (0.15µm)
Color
Black
Product Type
Receptacles / Sockets - Housings
Contact Gender
Socket (Female)
Number Of Positions / Contacts
50
Mounting Style
Cable
Mounting Angle
Vertical
Termination Style
IDC
Housing Material
Polybutylene Terephthalate (PBT)
Voltage Rating
250 V
Current Rating
1 A
Contact Termination
IDC / IDT
Gender
Receptacle
No. Of Contacts
50
No. Of Rows
2
Pitch Spacing
2.54mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Fastening Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
OR987
XG4M5030T
XG4M5030T
Industry Standard Circuit Board
Connectors Conform to MIL Standards
• XG4M-U: Unique locking system, with lock levers on strain
• Space-saving Box-type Plugs (XG4C) available.
• Can be used with XG5 IDC Connectors for discrete wires, XG8
• The Original Plugs (XG8) and the Box-type Plugs (XG4C)
• Conforms to MIL standards (MIL-C-83503).
• UL recognition (file No. E103202)
Ordering Information
Note: 1. XG4M can be provided with or without the strain reliefs;
■ Ratings and Characteristics
Rated current
Rated voltage
Contact resistance
Insulation resistance
Dielectric strength
Connector insertion
Contact removal
Insertion durability
Ambient temperature
relief / socket instead of on plug, saves 24% of space
Original PCB Plugs, and the XG2 IDC Bus Connectors for PCBs.
can be locked using External XG5Z and XG4Z Lock Levers.
Flat Cable Connectors
XG4
Appearance
Strain relief
Connector
Feature
2. XG4H PCB mount socket mates with XG4C and XG8W (see XG8 Datasheet) for board to board connectivity without cables.
3. XG5 connectors (see XG5 Datasheet) use discrete wire instead of flat ribbon cable.
4. XG4A PCB mount sockets are available with Long, Short or no Lock Levers.
5. Optional XG4Z-001@ side-lock levers, purchased separately, are available for use with right-angle XG4A versions that don’t include them.
6. Optional XG4Z-0002 and XG5Z-0002 top-lock levers are available for mating XG4M(-T) sockets to XG4C and XG8 plugs.
⇒ XG4M-U consists of XG4M-@@3@ socket +XG4U-@@04 strain relief
⇒ XG4M-T consists of XG4M-@@3@ socket + XG4T-@@04 strain relief
Item
with lock levers
Strain relief
XG4U
1 A
250 VAC
20 mΩ max. (at 20 mV, 100 mA max.)
1,000 MΩ min. (at 500 VDC)
500 VAC for 1 min (leakage current: 1 mA max.)
1.96 N max. per contact
0.39 N min. (with test gauge, t= 0.64 mm)
50 times (See note 2.)
Operating: –55 to 105°C (with no icing)
Socket
XG4M
MIL Sockets: XG4M
Cable Plug: XG4E
without lock levers
Strain relief
Cable
XG4T
Lock levers on
connector
XG4E
XG4S
3 A (See note 1.)
300 VAC
Plug
Board to Board Sockets: XG4H
Box-type PCB Plugs: XG4C
MIL Plugs: XG4A
lock levers
Integral
XG4A
- - -
with lock levers
Flat Cable Connectors
XG4A
Plug
2-tier
- - -
Note: 1. The rated current will depend on the
2. For standard 0.15-μm gold plating.
PCB
Socket you are using. It is 1 A using
the XG4M for example.
Box type plug
XG4C
- - -
XG4
Board to Board
Socket
Socket
XG4H
- - -
41

Related parts for XG4M-5030-T

XG4M-5030-T Summary of contents

Page 1

... XG4A PCB mount sockets are available with Long, Short or no Lock Levers. 5. Optional XG4Z-001@ side-lock levers, purchased separately, are available for use with right-angle XG4A versions that don’t include them. 6. Optional XG4Z-0002 and XG5Z-0002 top-lock levers are available for mating XG4M(-T) sockets to XG4C and XG8 plugs. ■ Ratings and Characteristics ...

Page 2

... XG4U Strain Relief with Locks) Mates with XG4 42 Flat Cable Connectors Cable Plugs: XG4E MIL Sockets: XG4M (Strain Relief: XG4S) (Strain Relief: XG4T) Polyamide resin (UL94V-0)/ Fiber-glass reinforced PBT black resin (UL94V-0)/black Phosphor bronze/nickel base, 0.15-μm gold plating (See note.) ...

Page 3

... XG4T + XG4M + XG8 (Unshrouded Plug) + XG5Z Lock Lever XG4U XG4T XG4M XG4M 18.8 XG4C XG8B XG5Z-0002 Lock Lever Flat Cable Connectors XG4T + XG4M, + XG4C + XG4Z Lock Lever XG4T XG4M 10.9 19.0 27 XG4C XG4Z-0002 Lock Lever XG4T + XG4M + XG4E 9 24.7 28.1 XG4 ...

Page 4

... XG4M-3030 XG4M-3430 XG4M-4030 XG4M-5030-U 2 (See note 4.) XG4M-5031 XG4M-6030-U 2 (See note 4.) XG4M-6031 XG4M-6430-U 2 (See note 4.) XG4M-6431-U Note: 1. Sets include the connector and strain relief. 2. With open-end cover. XG4 44 Flat Cable Connectors Mating Diagrams for XG4M-U XG4U + XG4M + XG4C XG4U 9.5 5.6 6.7 XG4C (16 ...

Page 5

... XG4M-2030 XG4M-2630 XG4M-3030 XG4M-3430 XG4M-4030 XG4M-5030-T 2 (See note 4.) XG4M-5031 XG4M-6030-T 2 (See note 4.) XG4M-6031 XG4M-6430-T 2 (See note 4.) XG4M-6431-T Note: 1. Sets include the connector and strain relief. 2. With open-end cover. 3. Strain Relief sold separately. 4. Polarity guide pitch is 22.86 mm Strain relief Open-end cover Polarizing Key slot (2) ...

Page 6

XG4E Plugs and XG4S Strain Relief Dimensions XG4E-@@31/-@@71 (With long locks) (Long locks) XG4E-@@32/-@@72 (With short locks) 0.635 × 0.635 XG4S-@@04 Strain Relief XG4 46 Flat Cable Connectors (Locking Levers on Connector) Open-end cover Strain Relief Two, 2.6 dia. ...

Page 7

... Ordering Information Use Long-lock Plugs to mate with XG4M-T Strain-relief Sockets, and use Short-lock Plugs to mate with XG4M that does not have a strain relief installed. No. of No. of Long-lock Plugs with Open-end Cov- contacts polarizing ers (See note 1.) slots 10 0 XG4E-1071 1 XG4E-1031 14 1 XG4E-1431 ...

Page 8

PCB Mount Connectors ■ XG4A Plugs with Long Lock levers Dimensions XG4A-@@31/-@@71 (With straight DIP terminals) XG4A-@@34/-@@74 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Polarity slot Polarizing Key slot Polarizing Key slot (not on models with less ...

Page 9

... Ordering Information Use in Combination with XG4M-T cable mount Sockets with strain relief or XG5M Sockets for discrete wire. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1071 1 XG4A-1031 14 1 XG4A-1431 16 1 XG4A-1631 20 1 XG4A-2031 26 1 XG4A-2631 30 1 XG4A-3031 34 1 XG4A-3431 ...

Page 10

XG4A Plugs with Short Locks Dimensions XG4A-@@32/-@@72 (With straight DIP terminals) XG4A-@@35/-@@75 (With right-angle DIP terminals) Straight DIP terminals Right-angle DIP terminals Triangular Polarity slot mark Polarizing Key slot Polarizing Key slot (not on models with less than 14 ...

Page 11

... Ordering Information Use in Combination with XG4M cable mount Sockets without strain relief. No. of No. of Plugs with straight DIP terminals contacts polarizing slots 10 0 XG4A-1072 1 XG4A-1032 14 1 XG4A-1432 16 1 XG4A-1632 20 1 XG4A-2032 26 1 XG4A-2632 30 1 XG4A-3032 34 1 XG4A-3432 40 1 XG4A-4032 50 1 XG4A-5032 2 (See note ...

Page 12

XG4A Plugs without Lock Levers Note: XG4Z-001@ Lock Levers that can be installed after PCB assembly may be purchased separately. (See the following page.) Dimensions XG4A-@@33/-@@73 (With straight DIP terminals) XG4A-@@36/-@@76 (With right-angle DIP terminals) Straight DIP terminals Right-angle ...

Page 13

... Plug. 2. Use Long Lock Levers when mating XG4A plug to XG4M-T cable mount socket with strain relief or XG5M sockets for discrete wires. 3. Use Short Lock Levers when mating XG4A plug to XG4M without strain relief attached. Flat Cable Connectors Min. order ...

Page 14

XG4A 2-tier Plugs with Long Lock Lever Dimensions XG4A-@@39-A/-@@79-A (With long locks and right-angle DIP terminals) No. of Dimensions (mm) contacts × 2 32.0 17.5 10.16 21.8 46.4 14 × 2 37.1 22.6 ...

Page 15

... XG4A-6439-A XG4M-6430 2 (See note 3.) XG4A-6479-A XG4M-6431 Note: 1. Use with the XG4T strain relief. (XG4M-T includes the connector and strain relief as a set.) 2. Use with the XG5S Semi-cover. XG5S Hood Cover cannot be used. (See XG5 Datasheet). 3. Polarity slot pitch is 22.86 mm. Correct Use of XG4A 2-tier Plug Mounting • ...

Page 16

... XG4C-6071 64 1 XG4C-6431 2 (See note 1.) XG4C-6471 Note: 1. Polarizing slot pitch is 22.86 mm. 2. The Box-type Plug can be locked to XG4M and XG5 using the “XG4Z-0002” Lock Lever II (sold separately). XG4 56 Flat Cable Connectors Polarizing Key slot (Not on models with Polarity slot Polarizing Key slot less than 14 contacts ...

Page 17

XG4H Board-to-Board Sockets Dimensions XG4H-@@31/-@@71 (With straight DIP terminals) 6.1 3.8 Polarizing Key slot 2.45 (Not on models with Polarizing Key slot less than 14 contacts.) (Not on models with less than 10 Polarity guide Triangular contacts.) 3 mark ...

Page 18

Mating Diagrams for XG4H Plug Socket XG4H-@@31/-@@71 (With straight DIP 2.54 terminals) XG8W XG4H 2.54 Stacking XG4H-4034 (With right-angle DIP XG8W terminals) 15.23 6.82 0.52 Horizontal (forward direction) XG4 58 Flat Cable Connectors XG8W Original Plugs (See XG8 Datasheet) ...

Page 19

... XG4A-143@ XG4E-103@ XG4E-143@ — XG4C-103@ XG4C-143@ — Flat Cable Connectors contacts XG4M-1630 to XG4M-6430 Polarizing Key slot XG4M-5031, XG4M-6031, XG4M-6431 Polarizing guide XG4A-163@ to XG4A-643@ Polarizing Key slot XG4E-163@ to XG4E-643@ XG4A-507@, XG4A-607@, XG4A-647@ Polarizing slot XG4E-507@, XG4E-607@, XG4E-647@ XG4C-163@ to XG4C-643@ Polarizing slot XG4C-507@, XG4C-607@, XG4C-647@ ...

Page 20

... Install the XG4Z-0004 polarizing key on XG4A, XG4E and XG4C plugs that do not have a polarizing slot, to prevent reverse connec- tion with XG4M cable sockets that do not have a polarizing guide. For all other versions, the molded polarity guides and slots can be used by themselves to help prevent reverse insertion. However, use the polarizing key with these versions as well for best results ...

Page 21

MEMO XG4 Flat Cable Connectors ...

Page 22

... All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B ...

Related keywords