GLD-01-040 SOLA HEVI DUTY, GLD-01-040 Datasheet

POWER SUPPLY, SWITCH MODE, 5V

GLD-01-040

Manufacturer Part Number
GLD-01-040
Description
POWER SUPPLY, SWITCH MODE, 5V
Manufacturer
SOLA HEVI DUTY
Type
Industrialr
Datasheets

Specifications of GLD-01-040

Power Supply Type
Open Frame
No. Of Outputs
2
Output Voltage
5V
Output Current
3A
Power Rating
40W
Output Type
Fixed
Output Current 1
3A
Output Current 2
2A
Output Power
40W
Product
Switching
Commercial/medical
Commercial
Output Power Rating
15 W
Input Voltage
85 VAC to 264 VAC
Number Of Outputs
2
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 VDC
Output Current (channel 2)
2 A
Mounting Style
Socket
Dimensions
127 mm L x 76.2 mm W x 34.5 mm H
Open Frame/enclosed
Open Frame
Brand/series
GL Series
Configuration
Open-Frame
Current, Output 1
3
Current, Output 2
2 A
Efficiency
65% (Min.)
Frequency, Input
47 to 63 Hz
Mounting Type
Panel
Operation
Switching
Output
5 VDC @ 3 A, 12 VDC @ 2 A
Power, Output
40 W
Primary Type
AC-DC
Regulation, Line
±0.5 %
Regulation, Load
±1% (Single Output)⁄±2% (Main Output)
Standards
UL Recognized, CSA Certified, CE Approved, LVD
Temperature, Operating
0 to +50 °C
Voltage, Input
85 to 264 VAC
Voltage, Output
5, 12 VDC
Voltage, Output 1
5 V @ 3 A
Voltage, Output 2
12 V @ 2 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications:
Mating Connector Kits
-
-
-
Overvoltage Protection
Operating Temperature
Required Minimum
Storage Temperature
Shock & Vibration
Cross Regulation
Temp. Coefficient
Load Regulation
Line Regulation
Inrush Current
Can be ordered separately for units with Molex connection.
Used for input and output connection (applies to 40, 65, 110 watt units).
o
Use for auxiliary signal connector only (200 watt units)
Output Ripple
Input Voltage
Hold up Time
Parameter
Frequency
Protection
Efficiency
Cooling
Load
Safety
MTBF
Kits include mating housing and pins for input and output
connection:
EMI
GL40-KIT
GL65-KIT
GL110-KIT
GL200-KIT
Full Rated Load
Full Rated Load
Full Rated Load
Full Rated Load
Full Rated Load
Per MIL-HDBK-
Main Output
Condition
All Models
Cold Start
#1 Output
Full Load
General
Output
Input
217E
Convection Cooling 200 W
FCC20780 Level B & VDE
UL 1950, CSA C22.2 No.
units have an internal fan
±1% Single Output ±2%
112 to 132% of Nominal
Designed to meet MIL-
2% peak to peak max.
Line Fuse on board
15 to 60 A Max
85 to 264 VAC
234, EN 60950
100,000 hour
0871 Level A
-20 to +85°C
Main Output
47 to 63 Hz
±0.04%/ °C
10 mS min.
5% Typical
STD 810C
0 to 50°C
65% min.
±0.5%
Limit
10%
Selection Table for 200 Watt, GL Series:
Output Connector (Terminal Block):
Auxiliary Signal Connector:
GLS-01-200
GLS-02-200
GLS-03-200
GLS-04-200 24 V, 8.4 A
GLD-01-200
GLD-02-200
GLD-03-200
GLT-01-200
GLT-02-200
GLT-03-200
GLT-04-200
GLQ-01-200
GLQ-02-200
GLQ-03-200
GLQ-04-200
GLQ-05-200
Model
All Models
Number
GLQ
Catalog
GLS
GLD
GLT
Model
Output 1
Output 1
Output 1
Pin 1-2
- Sense
12 V, 16.7
15 V, 13.4
Output 1
5 V, 40 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
5 V, 30 A
A
A
Pin 1
Fan
Pin 3-4-5
Common
Common
Common
Return
Output 2
12 V, 8 A
15 V, 6 A
24 V, 4 A
12 V, 8 A
12 V, 8 A
15 V, 6 A
15 V, 6 A
12 V, 8 A
15 V, 6 A
12 V, 8 A
12 V, 8 A
12 V, 8 A
-
-
-
-
Common
Pin 2
Output 1 Output 1 Output 1 +Sense
Output 2
Output 2 Output 3
Output 2 Output 3
Pin 6
-12 V, 4 A
-15 V, 4 A
-12 V, 4 A
-12 V, 4 A
-15 V, 4 A
-12 V, 4 A
-15 V, 4 A
-12 V, 4 A
Output 3
-5 V, 6 A
-
-
-
-
-
-
-
Pin 7
N/A
Common
Pin 3
Output 4
24 V, 4 A
12 V, 4 A
15 V, 4 A
24 V, 4 A
5 V, 6 A
Output 4
Return
Pin 8
-
-
-
-
-
-
-
-
-
-
-
N/A
N/A
Maximum
Output 4
Output
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
Pin 4
PFD
Pin 9
N/A
N/A
Notes:
1. Tolerance 0.02/0.5 maximum.
2. Input connector P1 and output connector P2 equipped with #6-32 screws on 0.375-inch centers.
3. Connectors P3 mates with Molex housing 22-01-1043 and Molex 4809 series crimp terminal.
4. Weight: 3.9 lbs. (1,750 grams) approx.
5. Input/Output Mating Connector kit available. Catalog number GL110-KIT.
6. All dimensions in inches (mm).
GL Series
Power Supplies
Single and Multi Output Switchers
Rev. 03/24/05
GL 40
GL 65
GL 110
GL 200
USA
International
Email
www.solaheviduty.com
Technical Services
tech@sola-hevi-duty.com
(800) 377-4384
(847) 268-6000

Related parts for GLD-01-040

GLD-01-040 Summary of contents

Page 1

... - 200 W Output Connector (Terminal Block): Model Pin 1-2 Pin 3-4-5 Pin 6 Pin 7 Pin 8 Pin 9 GLS - Sense Return Output 1 Output 1 Output 1 +Sense GLD Output 1 Common Output 2 N/A N/A N/A GLT Output 1 Common Output 2 Output 3 N/A N/A Output 4 GLQ Output 1 Common Output 2 Output 3 ...

Page 2

... Selection Table for 40 Watt, GL Series: Catalog M aximum Output 1 Output 2 Output 3 Number Output GLS-01-040 GLS-02-040 GLS-03-040 GLS-04-040 GLD-01-040 GLD-02-040 GLD-03-040 GLT-01-040 0 GLT-02-040 - GLT-03-040 - GLT-04-040 - GLT-05-040 - Output Connector: Model Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 GLS Output 1 Output 1 Output 1 ...

Related keywords