KCD2-STC-EX1 PEPPERL & FUCHS, KCD2-STC-EX1 Datasheet

no-image

KCD2-STC-EX1

Manufacturer Part Number
KCD2-STC-EX1
Description
SMART TRANSMITTER POWER SUPPLY
Manufacturer
PEPPERL & FUCHS
Datasheet

Specifications of KCD2-STC-EX1

Lead Free Status / Rohs Status
RoHS Compliant part
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com
Features
• 1-channel isolated barrier
• 24 V DC supply (Power Rail)
• Input 2-wire transmitters and 2-wire current sources
• Output 4 mA ... 20 mA or 1 V ... 5 V
• Sink or source mode
• Housing width 12.5 mm
• Up to SIL2 acc. to IEC 61508
Function
This isolated barrier is used for intrinsic safety applications.
The device supplies 2-wire SMART transmitters in a
hazardous area, and can also be used with 2-wire SMART
current sources.
It transfers the analog input signal to the safe area as an
isolated current value.
Digital signals may be superimposed on the input signal in the
hazardous or safe area and are transferred bi-directionally.
Selectable output of current source, sink mode, or voltage
output is available via DIP switches.
If the HART communication resistance in the loop is too low,
the internal resistance of 250 Ω between terminals 6 and 8
can be used.
Test sockets for the connection of HART communicators are
integrated into the terminals of the device.
Application
The device supports the following SMART protocols:
• HART
• BRAIN
Connection
SMART Transmitter Power Supply
Zone 0, 1, 2
Div. 1, 2
mA
1+
3+
2-
4-
Power Rail
KCD2-STC-Ex1
Front view
Switch 1 ... 4
Assembly
24 V DC
250 Ω
Copyright Pepperl+Fuchs, Printed in Germany
10-
7-
5-
6+
8+
9+
KCD2-STC-
S1
S2
S3
S4
1
3
5
7
9 10
PWR
24 V DC
Ex1
I
2
4
6
8
II
V
Zone 2
2
Div. 2
Removable terminals
blue
LED green:
Power supply
Place for labeling
Removable terminals
green
KCD2-STC-Ex1
1

Related parts for KCD2-STC-EX1

KCD2-STC-EX1 Summary of contents

Page 1

... Subject to reasonable modifications due to technical advances. Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com Assembly Front view Switch 1 ... 4 KCD2-STC-Ex1 250 Ω 10 Power Rail Copyright Pepperl+Fuchs, Printed in Germany KCD2-STC-Ex1 Removable terminals blue LED green: Power supply KCD2-STC- Ex1 PWR ...

Page 2

... Voltage U 7 Subject to reasonable modifications due to technical advances. Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com rms is no rated voltage.) m KCD2-STC-Ex1 0 ... 3 kHz (-3 dB ... 3 kHz (-3 dB) ss eff Copyright Pepperl+Fuchs, Printed in Germany 2 ...

Page 3

... EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl- fuchs.com. Subject to reasonable modifications due to technical advances. Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com KCD2-STC-Ex1 Copyright Pepperl+Fuchs, Printed in Germany 3 ...

Page 4

... The Power Rail must not be fed via the device terminals of the individual devices! Subject to reasonable modifications due to technical advances. Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com Operating mode Output as current source ... PWR Output as voltage source ... Output as current sink ... KCD2-STC-Ex1 Copyright Pepperl+Fuchs, Printed in Germany 4 ...

Related keywords