PAH
B-204
PAH
Pay attention to all warnings and cautions before using this unit.
Incorrect usage could lead to an electric shock, damage to the
unit, or a fire hazard. Be sure to read below warnings and cau-
tions before using the power module.
● Do not touch heatsink and case which may be hot.
● Do not open the case and touch the internal components.
● When the unit is operating, keep your hands and face away
● Confirm connections to input/output terminals and signal ter-
● Attach a fast blow type external fuse to each module to en-
● This power module is designed for professional installation
● The input supply, 18 - 36VDC must be isolated from the mains
1 Basic Connection
Note: This diagram is for Negative Logic “ON/OFF” Option.
They may have high temperature or high voltage which may
get you in electric shock or burned.
from the unit. You may get injured by accident.
minals are correct as indicated in the instruction manual.
sure safety operation and to acquire each safety standard ap-
proval.
within an end user equipment.
Warning
Caution
75D24
Input voltage measurement point
PAH75D24 SERIES Instruction Manual
2. Explanation on Specifications
1. Terminal Pin Configurations
Vin
Before Using This Power Module
FUSE
+ Vin
CNT
CASE
- Vin
NAME PLATE
Output voltage/input & load regulation
Output regulation measurment point
TRM2
TRM1
+ Vo2
+ Vo1
- Vo2
- Vo1
● PAH50S48 〜 200S48 Instruction Manual
● PAH300S24, 350S24 Instruction Manual
● PAH300S48, 350S48 Instruction Manual
L=50mm
● PAH450S48 Instruction Manual
● The application circuits and their parameter are for reference
● The information in this document is subject to change without
● No part of this document may be copied or reproduced in any
● Do not inject abnormal voltage to output or signal pins. Espe-
● Equipment with these products mounted inside must be pro-
primary power supply by reinforced insulation in accordance
with EN60950/UL1950.
tected to prevent contact with by technical service staff or
dropped tools, etc.
When repairing the equipment, please be sure to turn off input
sourse, and confirm that input and output voltage has dropped
down to a safe level.
only. Be sure to verify effectiveness of application circuits and
their parameters before finalizing circuit design.
notice. For actual design-in, please refer to the latest publica-
tions of data sheet, etc., for the most up-to-date specifications
of the unit.
form or by any mean without prior written consent of Densei-
Lambda.
cially, when inject negative voltage or voltage exceeding rated
output voltage to output pins might cause damage to internal
output capacitor (Functional Polymerized Capacitor).
● PAH200H Instruction Manual
−Vin : Negative Input Terminal
CASE : Baseplate Terminal
CNT
+Vin : Positive Input Terminal
+Vo2 : CH2 Positive Output Terminal
−Vo2 : CH2 Negative Output Terminal
TRM2 : CH2 Output Voltage Adjustment Terminal
+Vo1 : CH1 Positive Output Terminal
−Vo1 : CH1 Negative Output Terminal
TRM1 : CH1 Output Voltage Adjustment Terminal
+
+
Output ripple & noise measurement point
Bandwith of scope:20MHz
-
-
LOAD
LOAD
: ON/OFF Control Terminal
・All specifications are subject to change without notice.
B-175Page