PH50S24-5 TDK Corporation, PH50S24-5 Datasheet

no-image

PH50S24-5

Manufacturer Part Number
PH50S24-5
Description
POWER SUPPLY, OUTPUT CURRENT 10.00 AMPERE, POWER OUTPUT 50 WATT
Manufacturer
TDK Corporation
Series
PH-Sr
Type
Isolatedr
Datasheets

Specifications of PH50S24-5

Rohs Compliant
YES
Output
5V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
Module
1st Output
5 VDC @ 10A
Power (watts) - Rated
50W
Operating Temperature
-20°C ~ 85°C
Approvals
CE, CSA, EN, UL
Size / Dimension
-
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Other names
PH50S245
Q1073533

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH50S24-5
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH50S24-5
Manufacturer:
LAMBDA
Quantity:
292
Part Number:
PH50S24-5
Manufacturer:
SANREX
Quantity:
20 000
Part Number:
PH50S24-5
Quantity:
60
Part Number:
PH50S24-5/NV
Manufacturer:
LAMBDA
Quantity:
292
F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input range
Output Voltage Adj. Range
Line Regulation
Load Regulation
Ripple and Noise
Series Operation
Over Voltage Protection
Overload Protection
Remote On/Off
Remote Sensing
Parallel operation
Inverter Good signal
Thermal Protection
Cooling
Operating Temperature Range
Storage Temperature
Temperature Coefficient
Isolation
Isolation Resistance
Safety Agency Approval
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
High density
Low component count
Fixed operating frequency
Variety of input voltages
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
pk-pk
VDC
VDC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
150 - 180%
2.97~3.63
0.8% or 40mV (whichever is greater) from no load to full load with constant input line
Conduction or forced air. See application notes for cooling and heatsink selection
24V nom: 18-36, 48V nom: 36-76V, 110V nom: 82-185V, 280V nom: 200-400V
3.3V
0.4% or 20mV (whichever is greater) over entire input range with constant load
100mV
Baseplate temperature -20°C to +85°C (100°C on PH300 & PH600).
Simple function, 50 to 600W DC-DC converters
PH300S & PH600S only: Signal available for status of inverter
4.5~5.5
Input to output: 3000VAC, Input to Baseplate: 2500VAC(1)
Output to Baseplate -100MOhm at 500VDC and 70%RH
UL60950-1, CSA60950-1, EN60950-1 and CE Mark.
5V
PH300S & PH600S only: Requires external circuitry
PH-S Series
Approximately 105 - 140%, automatic recovery
-40°C to +85°C (+100°C on PH300 & PH600)
PH100S, PH150S, PH300S, PH600S models
-40°C start up possible - consult factory
Possible - Refer to installation manual
10.8~13.2 13.5~16.5
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Telecom
Custom Power Supplies
Point of Load
High Density
Wide Range Input
Output adjustment Capability
Remote On/Off
Fixed Switching Frequency
International Safety Approvals
12V
Internal sensing, self resetting
Benefit
Low = ON, Open = OFF
Smaller package size
High reliability Demonstrated 5 million hours MTBF
Easier system filtering
Systems can operate from different input voltages
150mV
0.02%/°C
Two years
15V
125 - 145%
21.6~26.4 25.2~30.8 43.2~52.8
240mV
24V
280mV
28V
480mV
48V
145

Related parts for PH50S24-5

PH50S24-5 Summary of contents

Page 1

Feature High density Low component count Fixed operating frequency Variety of input voltages ...

Page 2

... Output adjustment trim pin CNT On/Off Control Terminal CS Current Monitor Signal 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324 146 PH-S Series 24V input 48V input - PH50S48-3.3 - PH75S48-3.3 - PH100S48-3.3 - PH150S48-3 PH50S24-5 PH50S48-5 - PH75S48-5 - PH100S48-5 - PH150S48 PH50S24-12 PH50S48-12 - PH75S48-12 - PH100S48-12 - PH150S48- ...