AA2-B0-24-630-1B2-C Carling Technologies, AA2-B0-24-630-1B2-C Datasheet - Page 9

CIRCUIT BREAKER, HYD-MAG, 2P, 277V, 30A

AA2-B0-24-630-1B2-C

Manufacturer Part Number
AA2-B0-24-630-1B2-C
Description
CIRCUIT BREAKER, HYD-MAG, 2P, 277V, 30A
Manufacturer
Carling Technologies
Series
Ar
Datasheet

Specifications of AA2-B0-24-630-1B2-C

Input Voltage Vac
277V
No. Of Poles
2
Current Rating
30A
Interrupting Capacity
5kA
Dielectric Strength
1.5kV
Trip Time
20s
Trip Time Max
20sec
Product Type
Circuit Breakers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Notes:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
42
A-Series Rocker UL Recognized – Ordering Scheme
1 SERIES
A
2 ACTUATOR
Two Color Visi-Rocker
C
D
E
F
G
H
Push-To-Reset, Visi-Rocker
N
O
P
Single color
J
K
L
3 POLES
1
4 CIRCUIT
A
B
C
D
E
5 AUXILIARY/ALARM SWITCH
0
1
2
3
4
6 FREQUENCY & DELAY
03
10
11
12
14
16
20
21
22
24
26
3
4
4
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker
per breaker.
Switch Only circuits, rated up to 50 amps & 3 poles, are available with VDE Certification when tied to a protected pole (Circuit
Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip
instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are
supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50
amps.
Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA
Accepted available in one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal
Codes 5, 9, G, H, M and Q.
Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recom-
mended over 20 amps.
Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud)
with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.
VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50
amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C.
Terminal Code Q not available with VDE.
Terminal Code S used on voltage coil circuit constructions only.
Color shown is visi and legend with remainder of rocker black.
Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset
bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L.
1
Series
8
8
A
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate ON, no legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Indicate OFF, no legend
Indicate OFF,
vertical legend
Indicate OFF,
horizontal legend
Indicate OFF,
no legend
Vertical legend
Horizontal legend
No legend
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
w/o Aux Switch
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
DC Short
DC Medium
DC Long
50/60Hz Instantaneous
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium
50/60Hz Long
One
2
2
Actuator
1
F 1
3
Poles
2
6, 7
Two
4
Circuit
F
G
H
K
5
6
7
8
9
30
31
32
34
36
42
44
46
52
54
56
Push-To-Reset , Single color
R
U
V
B 0
4
4, 5
4, 5
4
9
9
9
9
9
Vertical legend
Horizontal legend
No legend
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
5
Aux/Alarm
Switch
3
Three
6
Frequency
& Delay
24
020
025
030
035
040
045
050
055
060
065
070
075
080
085
090
095
210
215
220
A06
A12
A18
A24
9 ACTUATOR COLOR & LEGEND
Actuator or _______Marking: _______
Visi-Color
White
Black
Red
Green
Blue
Yellow
Gray
Orange
7 CURRENT RATING (AMPERES)
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)
8 TERMINAL
1
2
3
4
5
6
7
8
9
B
C
10 MOUNTING/BARRIERS
1 6-32 x 0.195 inches
A 6-32 X 0.195 inches (multi-pole units only)
2 ISO M3 x 5mm
B ISO M3 x 5mm (multi-pole units only)
3 6-32 x 0.195 inches
C 6-32 x 0.195 inches (multi-pole units only)
4 ISO M3 x 5mm
D ISO M3 x 5mm (multi-pole units only)
8 without Rockerguard (single pole units only)
H with Rockerguard (single pole units only)
9 without Rockerguard (single pole units only)
J with Rockerguard (single pole units only)
11 AGENCY APPROVAL
C
D
E
I
12
13
13
7
Current Rating
STANDARD ROCKER BEZEL, Threaded Insert, 2 per pole
ROCKERGUARD & PUSH-TO-RESET BEZEL, Threaded Insert, 2 per pole
FRONT PANEL SNAP-IN BRACKET , 0.744” wide bezel
FRONT PANEL SNAP-IN BRACKET , 0.96” wide bezel
630
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 w/upturned lugs
and 30° bend
Screw 8-32 (Bus Type) and
30° bend
Screw 10-32 w/upturned lugs
and 30° bend
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
12 DC
18 DC
24 DC
0.020
0.025
0.030
0.035
0.040
0.045
0.050
0.055
0.060
0.065
0.070
0.075
0.080
0.085
0.090
0.095
0.100
0.150
0.200
6 DC
12
I-O
A
C
H
K
M
P
R
F
11
ON-OFF
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
415
517
A32
A48
A65
J06
G
Q
B
D
J
L
N
S
8
Terminal
20
2 3 1
32 DC
48 DC
65 DC
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
1.500
1.750
6 AC
Dual
1
2
3
4
5
6
7
8
12
9
Actuator
Color
____Marking Color:
Single Color Visi-Rocker
Black
White
White
White
White
Black
Black
Black
J12
J18
J24
J48
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
710
E
F
G
H
L
M
P
Q
R
S
T
13
14
15
17
13
13
16
www.carlingtech.com
10
Mounting/
Barriers
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Studs
Printed Circuit Board
Terminals
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
10.000
10.500
12 AC
18 AC
24 AC
48 AC
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
White
n/a
Red
Green
Blue
Yellow
Gray
Orange
BARRIERS
no
yes
no
yes
no
yes
no
yes
no
no
no
no
J65
K20 120 AC
L40
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
635
640
645
650
11
Agency
Approval
D
10
10
10
10
240 AC
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
65 AC

Related parts for AA2-B0-24-630-1B2-C