CIRCUIT PROTECTOR, HYD-MAG, 1P, 277V 10A

UPG6-1-72-103-01

Manufacturer Part Number
UPG6-1-72-103-01
Description
CIRCUIT PROTECTOR, HYD-MAG, 1P, 277V 10A
Manufacturer
AIRPAX
Series
UPGr
Datasheet

Specifications of UPG6-1-72-103-01

Input Voltage Vac
277V
No. Of Poles
1
Current Rating
10A
Interrupting Capacity
2kA
Dielectric Strength
1.5kV
Trip Time
20s
Voltage Rating Vdc
65V
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
140
IPG Decision Table - How to Order
The ordering code for IPG circuit protectors may be
determined by following the steps in the decision tables
shown here.
The coding given permits a self-assigning part number but
with certain limitations. Units with mixed ratings,
combinations of styles, or constructions not listed in the
third decision table, require a factory-assigned part
number. with these, it is suggested that order entry be by
description and/or drawings, and a part number will be
established. Additionally, it is standard policy to establish
a factory-assigned part number whenever a descriptive
drawing exists to provide cross reference, traceability and
manufacturing control.
when specifying a circuit protector for AC motor start or
high inrush applications, the peak amplitude and surge
duration should be specified for factory assistance in rating
selection.
For example, the following is the code for a single pole
IPG, quick-connect type terminal series unit with auxiliary
switch, designed for operation in a 50/60Hz circuit. It has a
short time delay and a rating of 20 amperes. Metric
mounting inserts and a white handle are also specified.
To determine the ordering number for your particular IPG
unit, simply follow the steps shown. You may use this
number to place an order or as a reference for further
questions you may have.
Notes:
A It is recommended that power leads be soldered to protectors having
B The standard current values for 100% of rated current are listed in the fifth
C All IPG protectors meet normal requirements for moisture and salt spray
D UL recognized and CSA certified applications above 30 amperes are
E when “A” is specified in the sixth decision in conjunction with IPG-6 type,
push-on terminals for current trip ratings above 10 amperes.
decision table. Please consult an Airpax office or sales representative for
other values.
resistance.
restricted to loads having a power factor of .75 minimum, and limited to
32Vdc only. VDE approval above 30 amperes is restricted to 32Vdc and
120Vac 50/60Hz. Standard terminals on ratings over 30 amperes are 10-32
screw type.
metric screw terminals are supplied.
APG/UPG/IPG Series - IPG Decision Tables
Type
IPG
IPGH
Push-On
Terminals
1
11
111
1111
1
2
3
*Only one auxiliary switch is normally supplied on two and
three pole units. Switch is located in the right-hand pole
(viewed from terminal end) unless otherwise specified.
First Decision
Type
Internal Configuration
Second Decision
Poles
Third Decision
Description
Single pole with one
handle per unit (Not
available in multi-pole
configuration)
Multi-pole with
handle per pole
Screw
Terminals
6
66
666
6666
Switch only (omit 4th and
5th decisions)
Series
Auxiliary switch*
.110 quick-connect
Auxiliary switch* (Gold
Contacts) .110 quick-connect
Auxiliary switch*
.187 quick-connect
Shunt (up to 30 amperes only)
http://airpax.sensata.com/
Number
of poles
Single pole
Two pole
Three pole
Four pole
Std. Handle Color
Black
Black

Related parts for UPG6-1-72-103-01