CIRCUIT BREAKER, HYD-MAG, 2P, 250V, 20A

NC1V-2111-20AS

Manufacturer Part Number
NC1V-2111-20AS
Description
CIRCUIT BREAKER, HYD-MAG, 2P, 250V, 20A
Manufacturer
IDEC
Datasheet

Specifications of NC1V-2111-20AS

Input Voltage Vac
250V
No. Of Poles
2
Current Rating
20A
Interrupting Capacity
2.5kA
Dielectric Strength
2kV
Trip Time
0.1s
Voltage Rating Vdc
125V
Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Type No. Development
Types
• Specity rated current, time delay curve, or voltage trip coil voltage in place of
Note: Inertia delay is for AC circuit. Also, time delay curve of S (instantaneous) is not available with inertia delay.
(Current Trip)
(Voltage Trip)
Series Trip
Relay Trip
Internal
Circuit
1
2
3
4
No. of
Poles
1-pole
2-pole
3-pole
1-pole
2-pole
3-pole
Type
NC1V: Flap actuator type
No. of Poles
1: 1-pole
2: 2-pole
3: 3-pole
Internal Circuit
1: Series trip (current trip)
5: Relay trip (voltage trip)
Auxiliary/Alarm Contacts
00: None
11: With one auxiliary contact
12: With two auxiliary contacts
13: With three auxiliary contacts
21: With one alarm contact
31: With one auxiliary contact and one alarm contact
32: With two auxiliary contacts and one alarm contact
Inertia
Delay
DIN rail and panel mounting
With
With
With
One Auxiliary Contact
One Alarm Contact
One Auxiliary Contact
One Alarm Contact
One Auxiliary Contact
Two Auxiliary Contacts
One Alarm Contact
One Auxiliary Contact
and One Alarm Contact
One Auxiliary Contact
Two Auxiliary Contacts
One Alarm Contact
One Auxiliary Contact
and One Alarm Contact
One Auxiliary Contact
Two Auxiliary Contacts
Three Auxiliary Contacts
One Alarm Contact
One Auxiliary Contact
and One Alarm Contact
Two Auxiliary Contacts
and One Alarm Contact
One Auxiliary Contact
Two Auxiliary Contacts
Three Auxiliary Contacts
One Alarm Contact
One Auxiliary Contact
and One Alarm Contact
Two Auxiliary Contacts
and One Alarm Contact
Auxiliary Contact
Alarm Contact
NC1V - 2 1 00 F - 30A A DC24V
NC1V-1100-
NC1V-1111-
NC1V-1121
NC1V-1100F-
NC1V-1111F-
NC1V-1121F-
NC1V-2100-
NC1V-2111-
NC1V-2112-
NC1V-2121-
NC1V-2131-
NC1V-2100F-
NC1V-2111F-
NC1V-2112F-
NC1V-2121F-
NC1V-2131F-
NC1V-3100-
NC1V-3111-
NC1V-3112-
NC1V-3113-
NC1V-3121-
NC1V-3131-
NC1V-3132-
NC1V-3100F-
NC1V-3111F-
NC1V-3112F-
NC1V-3113F-
NC1V-3121F-
NC1V-3131F-
NC1V-3132F-
NC1V-1500-
NC1V-2500-
NC1V-3500-
Ordering Type No.
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
8
8
8
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
Applicable Standards
8
7
6
5
6 7 8
NC1V Circuit Protectors
Voltage Trip Coil Voltage
DC24V: 24-48V DC
∗ Specified for relay trip only.
Time Delay Curve
M: Slow
A: Medium
S: Instantaneous
∗ For both AC/DC.
∗ Specified for series trip only.
Rated Current
0.1A, 0.3A, 0.5A, 1A, 2A, 3A,
5A, 7A, 10A 15A, 20A, 25A, 30A
∗ Specified for series trip only.
Inertia Delay
Blank: Without
F:
∗ Inertia delay is for AC voltage only.
∗ Available with medium and slow types
(not applicable with relay trip).
in the Ordering Type No.
With
6
Current
0.1A
0.3A
0.5A
10A
15A
20A
25A
30A
Rated
1A
2A
3A
5A
7A
M (slow)
A (medium)
S (instantaneous)
7
Time Delay
Curve
Code
8 Voltage Trip
Coil Voltage
DC24V
5

Related parts for NC1V-2111-20AS