T11-611-16 Schurter Inc, T11-611-16 Datasheet - Page 3

CIRCUIT BREAKER, THERMAL, 1P, 240V, 16A

T11-611-16

Manufacturer Part Number
T11-611-16
Description
CIRCUIT BREAKER, THERMAL, 1P, 240V, 16A
Manufacturer
Schurter Inc
Datasheet

Specifications of T11-611-16

Voltage Rating Vdc
48V
Voltage Rating Vac
240V
Current Rating
16A
No. Of Poles
1
Mounting Type
Snap-In
Terminals
Quick Tab
Actuation
Reset
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CIRCUIT BREAKERS FOR EQUIPMENT
GERÄTESCHUTZSCHALTER
20
Approvals
D
V
E
Technical data (continued)
Insulation resistance
Isolationswiderstand
Permissible ambient temperature
Zulässige Umgebungstemperatur
Type of actuation
Betätigungsart
Type of tripping
Auslöseart
Weight
Gewicht
UL
UL
VDE
Models 214, 314, 614 and 814 are only available for rated currents 6 A I n .
PCB mounting T11-818 by request.
Die Typen 214, 314, 614 und 814 sind nur für Nennströme 6 A I n lieferbar.
Ausführung für Leiterplattenmontage T11-818 auf Anfrage.
www.schurter.com
/ Approbationen
UL 1077
CSA C22.2 235
EN 60934
/ Technische Daten (Fortsetzung)
DC 500 V
DC 500 V
Reset type (manual)
Reset Typ (manuell)
• Thermal
• Positively trip-free
• Thermisch
• Positive Freiauslösung
Rated current range
Nennstrombereich
0,05 – 16 A
0,05 – 16 A
0,05 – 16 A
Rated voltage AC
Nennspannung AC
240 V
240 V
240 V
>100 M
>100 M
-5°C to +60°C
-5°C bis +60°C
R
R
TO
TO
approx. 10 g
ca. 10 g
Rated voltage DC
Nennspannung DC
48 V
48 V
48 V
T11