T9-611P-4A Schurter Inc, T9-611P-4A Datasheet

CIRCUIT BREAKER, PANEL MOUNT, 4A

T9-611P-4A

Manufacturer Part Number
T9-611P-4A
Description
CIRCUIT BREAKER, PANEL MOUNT, 4A
Manufacturer
Schurter Inc
Series
T9-611r
Datasheet

Specifications of T9-611P-4A

Voltage Rating Vdc
48VDC
Voltage Rating Vac
240VAC
No. Of Poles
1
Mounting Type
Panel
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
VDE, CCC
Approval Category
UL Recognised
Current
RoHS Compliant
Current Rating
4A
Rohs Compliant
Yes
2
Resettable Thermal Circuit Breaker, Single Pole, 4–16 A
Description
– Thermal circuit breaker
– Supplementary protector for general industrial use
– Cycling trip-free release
– Reset type
– Single pole
– Mounting style: T9-311: Threaded neck
Standards
– IEC 60934
– UL 1077
– CSA C22.2 235
– GB 17701
Technical Data
Typical internal resistance
Rated voltage
Rated current
Conditional short circuit capacitiy
Overload rating
Degree of protection
Endurance minimum
Endurance typical
Dielectric strength
Insulation resistance
Ambient temperature
Type of actuation
Type of tripping
Weight
T9-311: Threaded neck
Rated current
4 A
5 A
6 A
7 A
8 A
T9-611: Snap-in front side
T9-711: Snap-in rear side
Internal resistance
(mΩ)
21.6
23.6
16.3
15.3
12.9
T9-311 with cover TZZ31
circuit breakers
(see approvals)
IEC: Inc, PC1, AC 240 V
CSA: SC, AC 240 V / DC 48/32 V
According to CSA C22.2 235
Accessible range
Termination range
IEC: 200% In, cos phi 0.6
4–8 A: 150% In, cos phi 0.9
10–16 A: 150% In, cos phi 0.9
DC 500 V
5–16 A
4 A
Reset Type (manual)
Rated current
10 A
12 A
14 A
15 A
16 A
circuit breakers
Internal resistance
(mΩ)
Applications
– Power supplies
– UPS
– Power tools
– Household appliances
– Industrial appliances
– Medical diagnostic appliances
– HVAC
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
7.3
7.0
4.8
4.3
3.9
T9-611: Snap-in from front side
AC 240 V, 50/60 Hz
DC 48/32 V
4–16 A
2 kA
2 kA, C1
OL0 240 VAC
OL0 48 VDC and 32 VDC
IP 40
IP 00
min. 50 cycles
2500 cycles
6000 cycles
AC 1500 V
> 100 MΩ
-5 °C to 60 °C
-5 °C to 50 °C
R
Cycling trip-free
9 g
T9-711: Snap-in from back side

Related parts for T9-611P-4A

T9-611P-4A Summary of contents

Page 1

... Thermal circuit breaker – Supplementary protector for general industrial use – Cycling trip-free release – Reset type – Single pole – Mounting style: T9-311: Threaded neck T9-611: Snap-in front side T9-711: Snap-in rear side Standards – IEC 60934 – UL 1077 – ...

Page 2

... Rated currents Rated voltage AC 4–12 A 240 V > 12–16 A 240 V 4–12 A 240 V > 12–16 A 240 V 4–12 A 240 V > 12–16 A 240 V 4–16 A 240 V circuit breakers Correction factor -5 0,85 0,95 1,00 1,08 1,21 10,0 A +60°C 1,21 10 1,21 = 12,1 A Rated voltage ...

Page 3

... Snap-in type from front side (0.8…2.0 mm) 7 Snap-in type from rear side (0.5…3.0 mm) Actuation type 1 Reset Type (R-type) Terminal type 1 6.3 x 0.8 mm quick connect terminals IEC 61210 Front printing C rated current not marked on front (T9-311 and T9-711) P rated current printed on front (T9-611 only) Rated current ...

Page 4

... Panel thickness S = 0.8–5.5 mm T9-611 ±0.2 ø 15.4 3.4 8 +0.15 +0. Panel thickness S = 0.8–2.0 mm Recommended panel thickness: 0.8/1.2/1.6/2.0 mm T9-711 ±0.2 ø 15.4 3 13.9 -0.1 Panel thickness S = 0.5–3.0 mm www.schurter.com/pg17_18_19 36.1 10 6.3x0.8 max. torque 0 6.3x0.8 +0. 43.1 10 6.3x0.8 circuit breakers 19 3/8" -27UNS ...

Related keywords