1658-G21-02-P10-20A ETA, 1658-G21-02-P10-20A Datasheet

CIRCUIT BREAKER, 20A

1658-G21-02-P10-20A

Manufacturer Part Number
1658-G21-02-P10-20A
Description
CIRCUIT BREAKER, 20A
Manufacturer
ETA
Datasheet

Specifications of 1658-G21-02-P10-20A

Voltage Rating Vdc
28V
Voltage Rating Vac
250V
Fuse Current
20A
No. Of Poles
1
Mounting Type
Panel
Approval Bodies
CSA, UL, VDE
Current Rating
20A
External Depth
27mm
External Length / Height
32mm
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Very cost effective design to meet international requirements. No
exposed metal parts which are, or could become, current-carrying
except for terminals. R-type TO CBE to EN 60934.
G
G
G
Battery chargers, consumer products, power supplies, motors.
Type No.
1658
1658 - G21 - 02 - P10 - 5 A
* Screws and lock washers bulk shipped
Current
rating (A)
5
6
7
8
9
10
05/06
Description
Typical applications
Ordering information
Standard current ratings and typical voltage drop values
Manual reset, cycling trip free mechanism
Extremely small and lightweight
UL, CSA, VDE and EN 60934 (IEC 60934) approved
(280405)
single pole thermal circuit breaker
Threadneck design
G21
G41
A21
A41
A00
F01
snap in
auto reset type, 3/8"-27 threadneck
auto reset type, 7/16"-28 threadneck
auto reset type, without threadneck
manual reset type, 3/8"-27 threadneck
manual reset type, 7/16"-28 threadneck
Hardware
00
01
02
03
04
05
06
07
08
Voltage
drop (mV)
≤ 150
≤ 150
≤ 150
≤ 150
≤ 150
≤ 140
no hardware
one PAL nut, bulk
one PAL nut, one knurled nut, bulk
one PAL nut mounted
one PAL nut, one knurled nut, mounted
one PAL nut mounted, one knurled nut, bulk
one knurled nut, bulk
one hex nut, bulk
two hex nuts, bulk
Terminals
P10
P13
S80
S83
Thermal Overcurrent Circuit Breaker 1658-...
blade terminals A6.3-0.8 (QC .250)
blade terminals A6.3-0.8 (QC .250), 90°
straight screw terminals*
90° bent screw terminals*
Current ratings
5 ...30 A
Ordering example
Current
rating (A)
12
15
16
20
25
30
Voltage
drop (mV))
≤ 140
≤ 240
≤ 240
≤ 240
≤ 240
≤ 240
www.e-t-a.com
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077/EN 60934 PC1)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Authority
VDE (EN 60934)
UL
Technical data
Approvals
AC + DC
operating area
5...16 A
17...25 A
Voltage rating
AC 240 V; DC 28 V
AC 240 V
AC 120 V
AC 120 V
DC 28 V
cn
> 100 MΩ (DC 500 V)
AC 240 V; DC 28 V
5...30 A
1,000 operations at 2 x I
1,000 operations at 2 x I
-20...+60 °C (-4...+140 °F),
≤ 7 A max. +40 °C (+104 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
5...7 A
8...30 A 200 A
I
5...16 A
18...30 A
5...30 A
operating area IP40
terminal area IP00
8 g (57-500 Hz) ±0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
to IEC 60068-2-11, test Ka
to IEC 60068-2-78, test Cab
approx. 16 g
240 hours at 95 % RH
N
96 hours at 5 % salt mist,
1658-...
180 A
U
AC 240 V
AC 120 V
DC 28 V
N
Current ratings
5...25 A
5...16 A
20...30 A 1658-G...
5...30 A
5...30 A
pollution
degree
2
N
N
, inductive
, resistive
2,000 A
2,000 A
2,000 A
1658-G...
1658-A...
1658-G...
1

Related parts for 1658-G21-02-P10-20A

1658-G21-02-P10-20A Summary of contents

Page 1

... A6.3-0.8 (QC .250), 90° S80 straight screw terminals* S83 90° bent screw terminals* Current ratings 5 ...30 A 1658 - G21 - 02 - P10 - 5 A Ordering example * Screws and lock washers bulk shipped Standard current ratings and typical voltage drop values Current Voltage Current rating (A) ...

Page 2

... Thermal Overcurrent Circuit Breaker 1658-... Dimensions ø6 .236 17.5 .689 15.7 .618 32 1.26 A00 tightening torque max. 0.8 Nm A21 3/8-27UNS-2A G21 tightening torque max. 0.8 Nm 3/8-27UNS-2A A41 10 .394 G41 10 .394 F01 ø6 .236 Caution: Please keep a tight grip on the unit while removing the female connectors. ...

Page 3

... Thermal Overcurrent Circuit Breaker 1658-... Internal connection diagram 1 2 Typical time/current characteristics 10000 1000 100 … times rated current The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – ...

Page 4

... Thermal Overcurrent Circuit Breaker 1658-... Accessories Reset button seal for 3/8", 27-thread, short X201 285 01 1 3/8-27 UNS-2B Reset button seal for 7/16", 28-thread, short X222 119 01 7/16-28 UNS-2B long X200 799 01 3/8-27 UNS-2B long X222 119 02 7/16-28 UNS-2B This is a metric design and millimeter dimensions take precedence ( mm ) All dimensions without tolerances are for reference only ...

Related keywords