FD3150 EATON CUTLER HAMMER, FD3150 Datasheet - Page 187

CIRCUIT BREAKER, THERMAL MAG, 3P, 150A

FD3150

Manufacturer Part Number
FD3150
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 150A
Manufacturer
EATON CUTLER HAMMER
Series
Cr
Datasheet

Specifications of FD3150

Actuator Style
Toggle
No. Of Poles
3
Current Rating
150A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Screw
November 2008
F-Frame
Table 12-307. 600 Vac Maximum, 250 Vdc Maximum
CA08101001E
NEMA
Starter
Size
0
0
0
1
2
Cont.
Amps
15
30
50
3
7
Cam
Setting
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Motor
Full Load
Current
Amperes
(FLA)
10.4 – 11.4
11.5 – 12.6
11.5 – 13.7
13.8 – 16.0
16.1 – 18.3
18.4 – 20.6
20.7 – 22.9
23.0 – 25.2
11.5 – 15.2
15.3 – 19.1
19.2 – 22.9
23.0 – 26.8
26.9 – 30.6
30.7 – 34.5
34.6 – 38.3
38.4 – 42.1
1.1 –
1.3 –
1.6 –
1.8 –
2.0 –
2.3 –
1.5 –
2.1 –
2.6 –
3.2 –
3.7 –
4.3 –
4.8 –
5.3 –
3.4 –
4.6 –
5.7 –
6.9 –
8.0 –
9.2 – 10.3
6.9 –
9.2 – 11.4
.69 –
.92 –
1.0
1.2
1.5
1.7
1.9
2.2
2.5
2.0
2.5
3.1
3.6
3.9
4.7
5.2
5.7
4.5
5.6
6.8
7.9
9.1
9.1
.91
MCP
Trip
Setting
105
120
135
150
120
150
180
210
240
270
300
150
200
250
300
350
400
450
500
12
15
18
21
24
27
30
21
28
35
42
49
56
63
70
45
60
75
90
90
9
MCP
Catalog
Number
HMCP003A0C
HMCP007C0C
HMCP015E0C
HMCP030H1C
HMCP050K2C
For more information visit: www.eaton.com
Series C Molded Case Circuit Breakers
Motor Circuit Protectors
F-Frame
Price
U.S. $
Table 12-307. 600 Vac Maximum, 250 Vdc Maximum (Continued)
Note: HMCP 3 – 100 A come with line and load steel body terminals,
3T100FB. HMCP 150 A come with line and load steel body terminals,
3T150FB.
NEMA
Starter
Size
2
3
4
4
Motor FLA ranges are typical. The corresponding trip setting is at
13 x the minimum FLA value shown. Where a 13 x setting is required
for an intermediate FLA value, alternate Cam settings and/or MCP
ratings should be used.
For dc applications, actual trip levels are approximately 40% higher
than values shown.
Settings above 130 amperes are for special applications. NEC Article
430-110(a) requires the ampere rating of the disconnecting means to
be not less than 115% of the motor full load ampere rating.
Cont.
Amps
100
150
150
70
Cam
Setting
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Motor
Full Load
Current
Amperes
(FLA)
103.8 – 115.2
115.3 – 126.7
115.0 – 130.7
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
16.1 – 21.4
21.5 – 26.8
26.9 – 32.2
32.3 – 37.5
37.6 – 42.9
43.0 – 48.3
48.4 – 53.7
53.8 – 59.1
23.0 – 30.6
30.7 – 38.3
38.4 – 46.0
46.1 – 53.7
53.8 – 61.4
61.5 – 69.1
69.2 – 76.8
76.9 – 84.5
34.6 – 46.0
46.1 – 57.5
57.6 – 69.1
69.2 – 80.6
80.7 – 92.2
92.3 – 103.7
57.0 – 75.0
76.0 – 95.0
96.0 – 114.0
MCP
Trip
Setting
1000
1050
1200
1350
1500
1000
1250
1500
1750
2000
2250
2500
210
280
350
420
490
560
630
700
300
400
500
600
700
800
900
450
600
750
900
750
MCP
Catalog
Number
HMCP070M2C
HMCP100R3C
HMCP150T4C
HMCP150U4C
Price
U.S. $
12-187
12

Related parts for FD3150