HEB-BB Cooper/Bussmann, HEB-BB Datasheet - Page 2

FUSE HOLDER, 10.3 X 38MM

HEB-BB

Manufacturer Part Number
HEB-BB
Description
FUSE HOLDER, 10.3 X 38MM
Manufacturer
Cooper/Bussmann
Series
HEBr
Type
Fuse Holdersr
Datasheet

Specifications of HEB-BB

Voltage Rating Vac
600V
Fuse Current
30A
Fuse Holder Type
Fuse Holder
Holder Terminals
Wire Leads
No. Of Fuses
1
Fuse Size Held
13/32 X 1.1/2"
Fuse Size Imperial
13/32 X 1.1/2"
Product
Holder
Current Rating
20 Amps
Voltage Rating
250 Volts
Mounting Style
In-Line
Number Of Poles
1
Termination Style
Crimp, Crimp
Size (lxwxh)
10.32 mm x 41.275 mm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Breakaway Fuse Holders
Catalog Symbol: HEB
Description:
Single-pole breakaway in-line fuse holders for
midget fuses. Typical fuse types: BAF, DCM, FNM, FNQ AND
KTK.
Ratings:
Volts: 600V (or less)
Amps: Up to 30A*
Agency Information:
(1)
(2)
(3)
Coupling Nut Torque: 10-20lb-in.
Part Number Explanation
Example: HEB-AW-RYC
Part Number Selection
From the table on page three, select the combination of desired
loadside and lineside terminals for the application (define terminal
type, wire size, number of wires per terminal and whether the
terminal accepts solid and/or stranded conductors). Then in the
right hand two columns, select either the non-breakaway or
breakaway holder part number to order.
Available Part Numbers
*Amp rating limited by conductor size.
0908
UL Recognized, Guide IZLT2, File E14853
CSA Certified, Class 6225-01, File 47235
CE
• HEB = Holder series
• AW = Loadside terminal (copper crimp for #12 solid
• RYC = Lineside terminal (copper setscrew for two #6
Breakaway Units:
Fuse Holder Only: HEB-AW
copper wire)
solid copper wires)
Breakaway Part: RLC-A, RLC-B, RLC-C, RLC-J,
(Includes fuse holder, breakaway part and insulating
boots):
HEB-AW-RLA, HEB-AW-RLC-A
HEB-AW-RLC-C, HEB-AW-RLC-J, HEB-AW-RYA,
HEB-AW-RYC, HEB-BW-RLC-A, HEB-BW-RLC-B,
HEB-BW-RYC, HEB-JW-RLC-J, HEB-JW-RYC,
HEB-KW-RLC-J, HEB-KW-RYC, HEB-LW-RLA,
HEB-LW-RLC-J, HEB-LW-RYA
HEB-JW, HEB-LW
RYC, RLA, RYA
BU-SB08489
(2)
, HEB-BW
(1) (2) (3)
(2)
13
, HEB-AW-RLC-B,
3 2
, HEB-DW
˝ x 1
1
2
˝
(2)
,
Specification Data - Lineside Breakaway
Breakaway Receptacles
Terminal Type
Copper Crimp
Copper Setscrew
Aluminum Setscrew
Solid Breakaway
Insulating Boots
Two insulating boots come standard with the breakaway holders
(example: HEB-AW-RLC-A). The insulating boots are not
included with the non-breakaway holders (example: HEB-AA) or
the individual pieces of the breakaway holders (example:
HEB-AW, RCL-A). Two insulating boots must be ordered for
each holder when ordering them separately. When insulating
boots are utilized, extra heat retention requires that fuses are
sized at a minimum of 200% of the RMS load current.
Page 2 of 3
Data Sheet 2127
Conductor Data
Size
#12 to #8
#6
#4
#12 to #2
#12 to #2
#12 to #2
#12 to #2
(Required with
Breakaway
Receptacle)
Part Numbers
2A0660
2A0661
1
1
1
1
2
1
2
Type
Single conductor
Two conductor
Catalog
Symbol
-RLC-A
-RLC-B
-RLC-C
-RLC-J
-RYC
-RLA
-RYA
W

Related parts for HEB-BB