LCDA15.T Semtech, LCDA15.T Datasheet - Page 5

TVS DIODE ARRAY, 300W, 15V, SOIC

LCDA15.T

Manufacturer Part Number
LCDA15.T
Description
TVS DIODE ARRAY, 300W, 15V, SOIC
Manufacturer
Semtech
Datasheet

Specifications of LCDA15.T

Reverse Stand-off Voltage Vrwm
15V
Clamping Voltage Vc Max
30V
Peak Pulse Current Ippm
5A
Diode Case Style
SOIC
No. Of Pins
16
Diode Type
Bidirectional TVS
Peak Pulse Power Ppk @ 8x20us
300W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCDA15.TBT
Manufacturer:
SEMTECH
Quantity:
13 827
Device Connection for Protection of Two High-Speed
Data Lines
The LCDAxx is designed to protect up to two high-speed
data lines. The LCDAxx utilizes a low capacitance
compensation diode in series with, but in opposite
polarity to a TVS diode in each line. The resulting
capacitance is less than 5pF per line. Each line will
only suppress transient events in one polarity. There-
fore, to achieve protection in both positive and nega-
tive polarity, a second TVS/rectifier pair is connected in
anti-parallel to the first. Pins 1, 2, 7, and 8 are used to
protect one data line. Pins 3, 4, 5, and 6 are used to
protect the second data line.
The device is connected as follows:
Circuit Board Layout Recommendations for Suppres-
sion of ESD.
Good circuit board layout is critical for the suppression
of ESD induced transients. The following guidelines are
recommended:
PROTECTION PRODUCTS
Applications Information
2005 Semtech Corp.
Pins 1 and 2 are tied together and pins 7 and 8 are
tied together providing the protection circuit for
one I/O line. Pins 3 and 4 are tied together and
pins 5 and 6 are tied together providing the protec-
tion circuit for the second I/O line. Since the
device is electrically symmetrical, either side of the
connected pairs may be used to protect the lines.
The other side of the pair is used to make the
ground connection. The ground connections should
be made directly to the ground plane for best
results. The path length is kept as short as pos-
sible to reduce the effects of parasitic inductance
in the board traces.
Place the TVS near the input terminals or connec-
tors to restrict transient coupling.
Minimize the path length between the TVS and the
protected line.
Minimize all conductive loops including power and
ground loops.
The ESD transient return path to ground should be
kept as short as possible.
Never run critical signals near board edges.
Use ground planes whenever possible.
5
I/O 1
I/O 2
Line 1
In/Out
Line 1
In/Out
LCDA05 through LCDA24
Line 2
Ground
From Connector
LCDA Connection Diagram
1
2
3
4
1
2
3
4
1
2
3
4
Connection Options
I/O Line Protection
Line 2
In/Out
From Connector
To Protected
Device
To Protected
Device
8
7
6
5
8
7
6
5
Ground
Line 1
Ground
Line 2
In/Out
8
7
6
5
www.semtech.com
I/O 1
I/O 2

Related parts for LCDA15.T