PGR-5701-0U Littelfuse Inc, PGR-5701-0U Datasheet

no-image

PGR-5701-0U

Manufacturer Part Number
PGR-5701-0U
Description
BULK / GROUND FAULT RELAY - UNIVERSAL SUPPLY
Manufacturer
Littelfuse Inc
Datasheets

Specifications of PGR-5701-0U

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
© 2010 Littelfuse POWR-GARD
POWR-GARD
Ground-Fault Protection – Solidly & Resistance-Grounded System (5000 Family)
PGR-5701 SeRieS
Ground-Fault Relay
Wiring Diagram
Ordering Information
Note: For optional conformal coating please consult factory.
CataloG/SyStem NumbeR
PGR-5701-OD
PGR-5701-OT
PGR-5701-OU
aCCeSSoRieS
Current Transformers
PGA-0500
POWR-GARD
CURRENT TRANSFORMER
PGC FAMILY
(required)
1
9
POWR-GARD
GROUND-FAULT RELAY
PGR-5701 SERIES
®
CONTROL POWER
10
2
®
CT WIRING
A
Protection Relay Catalog
®
11
3
Protection Relays, Monitors & Systems
12
4
POWR-GARD
ANALOG % CURRENT METER
PGA-0500
13
5
®
TRIP
CoNtRol PoweR
9-36 Vdc Control Power
32-70 Vdc Control Power
75-275 Vac/dc Control Power
RequiRemeNt
Required
Optional
GF
(optional)
14
RESET
6
ANALOG
OUTPUT
15
7
TRIP
®
GF
16
+
8
B
PaGe
38
41
13
Description
The PGR-5701 is a microprocessor-based ground-fault relay for
resistance- and solidly grounded systems. It is uniquely suited for
use on systems with significant harmonic content. The PGR-5701
can provide main-plant protection, feeder-level protection, or
individual-load protection. Proper current transformer selection
provides the desired pickup range. The output contacts can be
connected for use in protective tripping circuits or in alarm indication
circuits. The analog output can be used with a PLC or a meter.
Features & Benefits
Specifications
IEEE Device Numbers
Input Voltage
Dimensions
Trip Level Settings
Trip Time Settings
Contact Operating Mode
Harmonic Filtering
Test Button
Reset Button
CT-Loop Monitoring
Output Contacts
Approvals
Communications
Conformally coated
Warranty
Mounting
Accessories
FeatuReS
Adjustable Pickup
(unlimited)
Adjustable Time Delay
(50 ms – 2.5 s)
Output Contacts
Analog Output
(0 – 5 V)
CT-Loop Monitoring
Selectable DFT or Peak
Detection Algorithm
Harmonic Filtering
Non-Volatile Trip
Memory
Microprocessor Based
Universal Power
Supply
A
B
PGC Family Ground-Fault Current Transformer
Required current transformer, model depending on
application. We offer a variety of sensitive CTs with
5- and 30-A primaries.
PGA-0500 Analog % Current Meter
Optional panel-mounted analog meter displays
ground-fault current as a percentage of the CT
primary rating.
Ground fault (50G/N, 51G/N)
See ordering information
H 75 mm (3.0"); W 55 mm (2.2"); D 115 mm (4.5")
1–99% CT-Primary Rating
0.05–2.5 s
Selectable fail-safe or non-fail-safe
Standard feature
Standard feature
Standard feature
Standard feature
Isolated Form A and Form B
CSA certified to US and Canadian standards
Analog output
Consult factory
5 years
DIN, Surface (standard)
Panel (with PGK-0055 or PGK-0060 adapter)
beNeFitS
Trip setting based on input CT primary, allows use
with any CT
Adjustable trip delay allows quick protection and
system coordination
Form A and Form B ground-fault output contacts for
operation of separate annunciation and trip circuits
Allows for connecting an optional (PGA-0500)
meter or a control system
Alarms when CT is not connected
Compatible with variable-speed drives
Eliminates nuisance tripping
Retains trip state when de-energized to simplify
troubleshooting
No calibration required saves on maintenance cost
Allows operation in application where one side
of PT is faulted
www.littelfuse.com/pgr-5701