PM100CL1B060 Powerex Inc, PM100CL1B060 Datasheet
PM100CL1B060
Specifications of PM100CL1B060
Available stocks
Related parts for PM100CL1B060
PM100CL1B060 Summary of contents
Page 1
... Applications: £ Inverters £ UPS £ Motion/Servo Control £ Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM100CL1B060 is a 600V, 100 Ampere Intellimod™ Intelligent Power Module. Type Current Rating V CES Amperes Volts (x 10) ...
Page 2
... V = 15V CIN 300V, I C(on 125°C off j t C(off 15V, T CES CE CES 15V CES D Symbol PM100CL1B060 T -20 to 150 j T -40 to 125 stg — 31 — 31 — 380 V 500 CC(surge) V 400 CC(prot.) V 2500 ISO V 600 CES ±I 100 C ±I 200 CP P 390 ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com PM100CL1B060 Intellimod™ L1-Series Three Phase IGBT Inverter 100 Amperes/600 Volts Electrical and Mechanical Characteristics, T Characteristics Control Sector Circuit Current Input ON Threshold Voltage Input OFF Threshold Voltage Short Circuit Trip Level ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com PM100CL1B060 Intellimod™ L1-Series Three Phase IGBT Inverter 100 Amperes/600 Volts OUTPUT CHARACTERISTICS (TYPICAL) 120 T = 25° 100 17V 0.5 1.0 1.5 COLLECTOR-EMITTER VOLTAGE (VOLTS) CE(sat) FREE-WHEEL DIODE FORWARD CHARACTERISTICS ...
Page 5
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com PM100CL1B060 Intellimod™ L1-Series Three Phase IGBT Inverter 100 Amperes/600 Volts SWITCHING TIME (ON) VS. COLLECTOR CURRENT (TYPICAL 300V 15V D INDUCTIVE LOAD T = 25° 125° COLLECTOR CURRENT (AMPERES) C SWITCHING TIME (OFF) VS. ...