PACDISPLAYPRO OPTO 22, PACDISPLAYPRO Datasheet - Page 4

Software

PACDISPLAYPRO

Manufacturer Part Number
PACDISPLAYPRO
Description
Software
Manufacturer
OPTO 22
Datasheet

Specifications of PACDISPLAYPRO

Kit Contents
PAC Display Professional Software, Documentation On CD, Plus Printed Documentation
Accessory Type
PAC Display Professional Software
Lead Free Status / RoHS Status
na
PAGE
4
Integration
SNAP PAC industrial controllers are programmed using PAC Control.
When you build a control program, or strategy, using PAC Control,
the database of I/O and variables you create in PAC Control is
automatically shared with PAC Display. This single tagname
database eliminates the need to create duplicate databases and
eliminates tagname-related errors.
Ease of Use
In PAC Display you construct your operator interface, referred to as a
project, by designing graphical objects and then linking them to
tags in the corresponding PAC Control strategy. On-screen windows
can combine pictures, symbols, bitmap graphics, and graphics with
3D effects. You can create graphics using built-in drawing tools,
import them from other applications, or select them from the
Symbol Factory, PAC Display’s extensive built-in library of industrial
automation graphics. Displays can also include controller-driven
animations and operator-driven commands.
Security
PAC Display lets you control access to an operator interface based on
users and groups defined in Microsoft Windows. Permissions can be
defined for individual on-screen controls, and access to the
interface itself can be password protected. Login and detailed usage
information can be saved to an encrypted operator action log file.
These security features can help applications meet U.S. FDA 21 CFR
Part 11 regulations for digital data recording, storage, and handling.
SuperTrends
With PAC Display’s SuperTrend feature, you can plot trends using
real-time data, historical data, or both, switching between current
data and previously logged data with the click of a button.
With 16 available pens, you can plot 16 variables or I/O points per
trend window. Point markers show you when data is actually
sampled. For historical data, you can just click on a point to see the
exact date, time, and value when the data was scanned.
Alarming
You can view and acknowledge alarms in PAC Display, as well as see
an alarm history for each alarm point. You can determine which
alarm points to set up, define alarm thresholds, and choose colors
for alarm states. Sound files can be added, and comments or
messages can be displayed in alarm graphics while PAC Display is
running.
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
© 2010 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
An automatic response to an alarm can be set up to provide
immediate action, such as automatically closing a valve when a
specific alarm goes off. You can also set priorities for alarms, so that
an operator can choose to receive only higher priority alarms during
startup, for example.
In addition, you can send the historical log of all alarms to a printer
and also to a user-configurable ASCII text file that can be easily
imported for analysis into Microsoft Excel, Access, or other
applications.
PAC Manager
PAC Manager is a configuration and maintenance tool used for:
PAC Manager includes tools for configuring multiple Ethernet
devices at once. For example, if you have I/O units that use the same
configuration, you can configure all of them simultaneously.
OptoOPCServer
OptoOPCServer is part of PAC Project Professional and can also be
purchased separately. A fast and efficient OPC 2.0-compliant server,
OptoOPCServer handles communications between multiple OPC
clients and Opto 22 devices. It lets OPC client software interface
with the following Opto 22 hardware:
OptoOPCServer can manage communication with Opto 22 devices
not only for OPC clients, but also for OptoDataLink and for multiple
seats of PAC Display. Because OptoOPCServer uses a report-by-
exception method of communicating with clients, it is strongly
recommended when multiple clients need to access Opto 22
systems. OptoOPCServer reduces network traffic on the industrial
automation and manufacturing network, and systems run faster.
Assigning IP addresses
Setting up security on Opto 22 Ethernet devices
Upgrading firmware
Configuring I/O points and I/O unit features
Inspecting, reading from, or writing to devices for testing
SNAP PAC System controllers running PAC Control strategies
Independent SNAP PAC EB brains
Legacy independent Ethernet-based I/O units
Controllers running legacy ioControl
OptoControl strategies
PAC Project Software Suite
and Ethernet-based